Professional Documents
Culture Documents
: 0 362 00/01/02/03/05/06/07/08/
11/12/13/16/17/25
CONTENT Page
1. General characteristics . . . . . . . . . . . . . . . . . 1
2. Range 2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3. Technical characteristics . . . . . . . . . . . . . . . . 2
4. Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
5. Accessories 4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lina 25 cable ducting is used to organise running the wiring vertically The ducting allows a cable tie to pass through the lateral perforations at
and horizontally inside a control system or distribution electrical the base of the ducting to clamp a sleeve or a cable.
enclosure.
The range covers requirements from 25x25 to 120x80 mm.
Lina 25 ducting can be cut to length without using a saw. After making
2 lateral cuts with the Lina 25 tool, the ducting can be separated
manually by a simple snap, thanks to the cut-outs on the bottom (quick,
no dust, no burrs).
2
1
The ends on Lina 25 ducting tabs are
designed to prevent injury. The space
between two tabs is 6 mm, which allows a
1.5 mm² cross-section cable maximum to
pass through without breaking the tab.
1 2 3
1/6
Lina 25 cable ducting Cat. No(s).: 0 362 00/01/02/03/05/06/07/08/
11/12/13/16/17/25
2. RANGE
Blue 2525 Afnor
Lenght 2 m
3.2 Standards
Covers only:
- Conforming to standard EN 50 085 part 2-3
Cat. No. Width Pack of - Conforming to ROHS: lead and cadmium-free
(mm) (m) - Blue 2525 according to AFNOR NF X08-002
- Approvals: UL, CSA (except cat. no. 0 362 03) and NF
0 370 41 25 36
0 370 42 40 36
3.3 Product classification according to EN 50085-2-3
0 370 43 60 36 - Non-metal product
0 370 44 80 36 - Method of opening cover: no tools required
- Minimum storage and transport temperature: - 25°C
0 370 46 120 36
-M aximum operating temperature: + 60°C
- Flame-retardant
- No electrical continuity
- Electrically insulating
- I nstallation position: on vertical or horizontal surface, cover facing
down not permitted
CONTENT 2/6
Lina 25 cable ducting Cat. No(s).: 0 362 00/01/02/03/05/06/07/08/
11/12/13/16/17/25
CONTENT 3/6
Lina 25 cable ducting Cat. No(s).: 0 362 00/01/02/03/05/06/07/08/
11/12/13/16/17/25
100 100
50 6,5 33,3 26,7
4. DIMENSIONS 100
6 5. ACCESSORIES Ø4
33,3 26,7 Ø4
Dimensions are in mm. 5.1 Fixing accessories
10
4.1 Lateral perforations 5.1.1 Linafix screwless fixing
50
78,6
10
100 100
33
50 6,5 Cat.33,3
No. Description
50
26,7
78,6
Ø4
6
33
18,6
0 367 00 Rail-fixing accessory for vertical ducting
18,6
10
- Polyamide 6-6.
50
78,6
33
18,6
4.2 Perforations on the base
2000
Largeur 15
Width 25 to 60 2000
1950 8 1950 8
2000 1 2 3 4
12,5 1950 14
8
4,5
14
Largeur 25 à 60
6,5
4,5
60
25
60
6,5
4,5
2000
25toà15
2000
12,5 50 12,5 1950 8
Largeur
1950 8
25
Largeur
12,5 14
Width
4,5
Largeur 25 à 60
6,5
4,5
12,5 25 12,5 12,5
25
Width
12,5 80 and
50120 12,5 Cat. No. Description
2000 0 366 40 2000 Rail-fixing accessory for horizontal ducting
1950 8 12,5 25 1950
12,5 8
12,5
2000
14 14 -U
sed to fix horizontal ducting on a rail,
1950 8
depth 15 mm.
14
6,5
-2000
Polyamide 6-6.
6,5
2000
120
80 // 120
25
4,5
1950 8 1950 8
25 25 25 25
6,5
4,5
Largeur 150
150 80
14 14
25
Largeur
Width
6,5
4,5
6,5
25
6,5 6,5
6,5
Largeur
25 2525 25
6,5
6,5
Largeur 80 / 120
25
6,5
25
4,5
Largeur 150
6,5
6,5
25
6,5
6,5 6,5
6,5
12,5 25 12,5 12,5 0 366 41 Accessory for fixing on Lina 25 perforated plate
6,5
Cat. No. A B C
2 3 4
0 362 00 25 25 6
0 362 01 25 40 5
0 362 02 25 60 6
1
0 362 03 25 80 6
0 362 05 40 25 10
0 362 06 40 40 10
0 362 07 40 60 10
0 362 08 40 80 10
0 362 11 60 40 10
0 362 12 60 60 10
0 362 13 60 80 10
0 362 16 80 60 10
0 362 17 80 80 10
0 362 25 120 80 10
CONTENT 4/6
Lina 25 cable ducting Cat. No(s).: 0 362 00/01/02/03/05/06/07/08/
11/12/13/16/17/25
2 3 4
Reinforced
- The reinforced rivet enables to fix cable ducting in 6.5 mm
1 hole of Lina 12.5 plate and perforated Lina 25 plate for
Atlantic and Marina cabinets.
- Polyamide 6-6.
CONTENT 5/6
Lina 25 cable ducting Cat. No(s).: 0 362 00/01/02/03/05/06/07/08/
11/12/13/16/17/25
5. ACCESSORIES (continued)
5.4 Wiring accessories
5.4.1 Wire-retaining clip
- For 120 mm wide ducting, two clips placed opposite one another can
be used to hold the wires in place.
120
CONTENT 6/6