ENGINEERING DATA SHEET


CCN: 47659924001

RS160i-A
Rev.: B
ECN: 1341195
Sheet: 1 of 1
60hz Date: 20-Mar-2020

Model 1 Air RS160i-A110 RS160i-A125 RS160i-A145 RS160i-A200

GENERAL PERFORMANCE DATA


(2)
Maximum Target Operating Pressure barg (psig) 7.6 (110) 8.6 (125) 10.0 (145) 13.8 (200)
Rated Discharge Pressure barg (psig) 6.9 (100) 7.9 (115) 9.3 (135) 13.1 (190)
Minimum Operating Pressure barg (psig) 4.5 (65) 4.5 (65) 4.5 (65) 4.5 (65)
Maximum Operating Ambient Temperature °C (°F) 46 (115) 46 (115) 46 (115) 46 (115)
Minimum Operating Ambient Temperature °C (°F) 2 (36) 2 (36) 2 (36) 2 (36)
Maximum System Temperature Setting °C (°F) 109 (228) 109 (228) 109 (228) 109 (228)
Nominal Power - Main Motor kW (HP) 149 (200) 149 (200) 149 (200) 149 (200)
(3) 96.2% 96.2% 96.2% 96.2%
Main Motor Efficiency %
(1)
Capacity FAD m³/min (CFM) 29.1 (1027) 28.0 (987) 25.7 (909) 21.3 (751)
(4) 170.8 174.0 173.9 176.6
Package Input Power with Fan - Air Cooled kW
(4)(5)
Specific Power - Air Cooled kW/m 3/min (kW/100CFM) 5.87 (16.6) 6.22 (17.6) 6.76 (19.1) 8.31 (23.5)

(6)
SOUND LEVEL
Noise Level Standard Package - Air Cooled Sound Pressure - dB(A) 68 68 68 68
Noise Level Standard Package - Air Cooled Sound Power - dB(A) 85 85 85 85

COOLING DATA (@ Maximum Ambient Temperature & Maximum Discharge Pressure)


Heat Removal (Oil Cooler) kW (1000 Btu/hr) 132.6 (452) 136.6 (466) 138.1 (471) 144.2 (492)
Heat Removal (Oil and Aftercooler) kW (1000 Btu/hr) 176.2 (601) 178.6 (609) 176.8 (603) 176.1 (601)

Permitted Additional Static Pressure Pa (in H2O) 63 (.25) 63 (.25) 63 (.25) 63 (.25)

Fan Air Flow m³/min (CFM) 363 (12819) 363 (12819) 363 (12819) 363 (12819)
Fan Motor Nominal Power kW 5.50 5.50 5.50 5.50

Cooling Air Temperature Rise @ 30°C °C (°F) 26 (46) 26 (47) 26 (47) 27 (48)
(7)
Aftercooler CTD °C (°F) 8 (14) 8 (14) 8 (14) 8 (14)

AIR END DATA


Male Rotor Speed RPM 1324 1281 1200 1016
Tip Speed Rotor m/sec 20.5 19.9 18.6 15.7
Full Load Shaft Power kW 153.4 156.6 156.6 159.5

(12)
COOLANT LUBRICATION DATA
Total Coolant Capacity - Air Cooled litres (US gal) 95 (25.1) 95 (25.1) 95 (25.1) 95 (25.1)

(8)
PIPING CONNECTIONS
Air Discharge Inches NPT 3.00 3.00 3.00 3.00
Package Automatic Condensate Drain Inches NPT 0.375 (FEMALE) 0.375 (FEMALE) 0.375 (FEMALE) 0.375 (FEMALE)
Coolant Drain - Hose Size Inches 0.500 0.500 0.500 0.500
Diameter of Power Inlet mm (Inches) 180 (7.1) 180 (7.1) 180 (7.1) 180 (7.1)

DIMENSIONS AND WEIGHT


Length, Width, Height mm (inches) 2855, 1899, 2107 (112.4, 74.8, 83.0) 2855, 1899, 2107 (112.4, 74.8, 83.0) 2855, 1899, 2107 (112.4, 74.8, 83.0) 2855, 1899, 2107 (112.4, 74.8, 83.0)
Net Weight - Air Cooled kg (lb.) 3820 (8422) 3820 (8422) 3820 (8422) 3820 (8422)
GA Drawing Number - Air Cooled 47615059001 47615059001 47615059001 47615059001

(13)
ELECTRICAL DATA
Motor Protection IP55 IP55 IP55 IP55
(9)
Full Load Package Current - Air Cooled

Amps @ 380V 349 355 355 361


Amps @ 460V 288 293 293 298
Amps @ 575V 231 235 235 238
(14)
Main Motor Locked Rotor Current

Amps @ 380V 3096 3096 3096 3096


Amps @ 460V 2580 2580 2580 2580
Amps @ 575V 2060 2060 2060 2060

Package Power Factor 0.82 0.82 0.82 0.82

Electrical Installation
(10)
Recommended Supply Cable Size

mm²/Cu (Kcmil) @ 380V 300 (600) 300 (600) 300 (600) 300 (600)
mm²/Cu (Kcmil) @ 460V 240 (500) 240 (500) 240 (500) 240 (500)
mm²/Cu (Kcmil) @ 575V 150 (300) 150 (300) 150 (300) 150 (300)
(10)(11)
Maximum Recommended Fuse Rating

Amps @ 380V 600 600 600 600


Amps @ 460V 500 500 500 500
Amps @ 575V 400 400 400 400
Notes:
1. FAD (Free Air Delivery) is full package performance including all losses. Tested per ISO 1217 : 2009 Annex C
2. Maximum pressure at package discharge, value at which compressor will stop when unit operating at maximum target pressure
3. IE3 efficiency motor
4. Measured at rated capacity and rated pressure
5. Specific power guaranteed in accordance with ISO 1217 : 2009 Annex C
6. Measured in free field conditions per ISO 2151 using Hemispherical Method; ducted inlet and outlet, with + 3 dB(A) tolerance
7. CTD based on 100°F/38°C inlet air at 40% Relative Humidity (For alternate conditions contact Ingersoll Rand)
8. BSPT or NPT, depending on regional standard
9. Maximum current includes 10% additional current due to fouled filters and elements
10. 90°C copper cables. Always apply local electrical codes for sizing cables and system protection
11. Time delay fuse recommended. Apply local electrical codes for fuse sizing
12. Coolant volumes listed are approximate. See operator manual for coolant fill proceedure
13. 60Hz (±0.5%) motor voltage tolerance: (208)±10% ; (220)±10% ; (230)±10% ; (380)-6/+10% ; (440) ±10% ; (460) ±10% ; (575) -6/+10%
14. Star-Delta starting current inrush is about 33% of direct starting current
15. During the Star-Delta open-starting transition, the in-rush current value could instantaneously peak from 1.8 to 2.8 times the noted Locked-Rotor-Amperage (LRA) values