1. Open a tap in the system.
7.1 Normal operation
2. Switch on the power supply.
3. Check that the "Power on", "Pump on" and When water is consumed in the water supply system,
"Alarm" indicator lights illuminate briefly. the PM 1 starts the pump when the starting
conditions of the unit are fulfilled. This happens for
– The pump is running, and a pressure will be example when a tap is opened which makes the
built up in the system. pressure in the system drop. The unit stops the
4. Close the tap. pump again when consumption stops, i.e. when the
5. Check that the pump stops after a few seconds tap is closed.
and that the "Pump on" indicator light goes out.
7.1.1 Starting and stopping conditions
The system is now ready for operation.
Starting conditions
If a pressure is not built up in the system The unit starts the pump when at least one of the
within 5 minutes after start-up, the dry- following conditions is fulfilled:
running protection will be activated, and • The flow is higher than Qmin..
Note the pump is stopped. Check the priming
conditions of the pump before attempting • The pressure is lower than pstart.
to restart the pump. Stopping conditions
Restart the pump by pressing [Reset]. The unit stops the pump with a time delay of
10 seconds when the following conditions are both
If the pump restarts immediately after fulfilled:
it has been stopped, the isolating valve • The flow is lower than Qmin..
used for checking for correct operation is
• The pressure is higher than pstop.
positioned too close to the PM unit.
A possible isolating valve installed The pstart, pstop and Qmin. values are shown in
immediately after the PM outlet must not section 11. Technical data.
Note be used for checking for correct operation.
The problem will be that the pipe length 7.2 Power supply failure
between the PM unit and the isolating In case of a power supply failure, the pump restarts
valve is too short, and therefore the automatically when power returns and runs for at
expansion of the pipe is too small. The least 10 seconds.
result is that the pressure will drop rapidly The setting of the anti-cycling function will not be
when the pump stops. affected by a power supply failure.