time with cycle

ment—blinks in
Write error N/A READ
shows measure-
Synchronized & automatically begins capturing data and can now be left unattended.
for almanac with PPS At this time the 3 LED’s will turn off and remain off. The Stationary CorrReader
timed out
satellites or wait blinks in time GPS
No GPS lock, the local time and battery level.
Searching for Has GPS lock— Screen displays the OFF, ON and AC readings along with
12:21:32 B= ▓▓▓▓
low, no SD card quence VAC = 00012.0V Screen, also all 3 LED’s will blink green. The Measurement
All checks ok POWER VON =-00956.2mV synchronization before displaying the Measurement
Problem – battery Initialization se-
VOFF=-00865.4mV The Stationary CorrReader obtains a GPS lock and
Red Yellow Green
Measurement Screen
message will display on the screen.
CorrReader goes to Measurement Screen. If an error is encountered, a text
then acquires satellites. When GPS locked and synchronized, the Stationary
level, SD card presence and valid programming. The GPS
conserve power. The LED’s are only active during power-up and GPS acquisition. B= ▓▓▓▓
initialization sequence confirming the battery
Stationary CorrReader’s LED’s do not stay on during unattended measurement to GPS Lock
The Stationary CorrReader performs an SD Card OK
different operational states. CATH-TECH V00.24
There are three LED’s on the face that blink. The colour of the LED indicates
Power
Lights Operation

Field Use CATH-TECH


Connect the black terminal/lead to a Cu/CuSO4 reference cell. Connect the red CORROSION CONTROL EQUIPMENT
terminal/lead to the pipe or test station.
Turn the Stationary CorrReader on and wait for
the start-up checks and measurement screen
- + Operation Manual for
to appear. For proper cathodic protection, the
reading should be negative; if positive, check
Stationary CorrReader
your wiring and/or rectifier output.
Stationary GPS Synchronized Test Station Reader
Do NOT survey during thunderstorms,
lightning may cause injury to personnel and/or
damage to the Stationary CorrReader.

Limited Warranty
All Cathodic Technology Limited (Cath-Tech) instruments and equipment are warranted against defects in
materials, design or workmanship for a period of two years from date of sale. This warranty excludes
damage due to misuse, abuse, tampering or acts of God such as fires, floods, wind damage, lightning etc.
We will repair or replace at our option any defective component, after examination in our manufacturing
facility, if the fault is due to defective materials or labour, within two years of the purchase date. For war-
ranty repair, a Returned Goods Authorization (RGA) must be obtained from Cathodic Technology Ltd prior
to shipping the defective unit pre-paid to our location.
Note: There is no warranty expressed or implied on batteries.
Cath-Tech Policy
Cath-Tech extends a two-year in use warranty on all units, which have been designed and/or manufactured
by Cath-Tech staff. Under normal circumstances there is no need to access the interior of the unit. To do so
without prior Cath-Tech approval will void any and all warranties. Cathodic Technology
Cath-Tech reserves the right to make any changes in design or specification which it deems an improve- Ltd.
ment, with no liability to make the same changes on existing equipment.
This warranty is in lieu of all other warranties or guaranties, expressed or implied, which might otherwise
15-1 Marconi Court
exist. The purchaser is relying only upon this guarantee and not upon any representations not herein Bolton, Ontario
expressed.
Canada L7E 1E2
Any material or equipment being returned to the factory must first have a Returned Goods Authorization
(RGA) from Cath-Tech. Ph: ++1-905-857-1050
ctl@cath-tech.com
© September 2013 by Cathodic Technology Ltd, Canada
www.cath-tech.com
Downloaded from www.Manualslib.com manuals search engine
Files
Memory
Display Stationary CorrReader uses a MicroSD card to store programmed settings and
data which must be installed for the CorrReader to function. To access the data,
turn the Stationary CorrReader on and connect to the computer with a USB
Power
cable. The SD card will appear as a drive on the computer and files can be copied
off and on to the card.
The SD card contains three types of files, a configuration file, calibration file and
data files.
CATHODIC TECHNOLOGY
LED’s  Configuration file - program information STPR CFG.TXT
TotalCycle [msec] = 4000,
 Data files - stored survey data OffTime [msec] = 1000,
StartWith = 0,
Configuration File MeasDelayON = 0,
MeasDelayOFF = 0,
CFG.TXT contains the programmed settings. These can LocalGPSTimeOffset = -5,
Enter be changed & saved in the same text file. If the file is
NumOfReadings = 1,
END
Navigation
accidentally deleted, the Stationary CorrReader will
Arrows create another one with the last good settings the next time it is turned on. The user must
set the same cycle/program the interrupters are set to.

Enter the total cycle time in milliseconds; 1000ms


TotalCycle [msec] = 4000, = 1 sec

OffTime [msec] = 1000, Enter the OFF time in milliseconds, must be


shorter than total cycle time
Pipe Connec-
Select 0 to start the cycle with OFF, or 1 to start
tion StartWith = 0,
the cycle with ON
ON measurement delay, set to 0 to calculate
1/2 Cell MeasDelayON = 0,
automatically (recommended)
Connection
Mini USB OFF measurement delay, set to 0 to calculate
MeasDelayOFF = 0,
automatically (recommended)
Change to the local time zone, CorrReader will
LocalGPSTimeOffset = -4, now display and store local time.
Dust Cover
Leave the value at 1 for continuous readings.
NumOfReadings = 1,

Troubleshooting Data Files


DATA####.CSV contains the survey data. A new data file is created every time
Problem Possible Solution the CFG.TXT is changed. The file header contains information on the Stationary
CorrReader (serial number, etc) and cycle settings.
Stationary CorrReader won’t Charge battery—plug in and press the power USB Port
turn on button
The USB port is located on the outside of the case, near the terminals. Use a
Ensure the Stationary CorrReader is outside MiniB USB cable, 2m long maximum. The USB port provides access to the SD
No GPS lock with a clear view of the sky, move away from card memory and charges the battery. For computer communication or charging
tall buildings the Stationary CorrReader must be powered ON.

Check all cable connections A dust cover is attached to the case to protect the USB port from dust, dirt, sand,
etc. under normal use. Ensure the cover is properly inserted into the USB port to
Remove half cell cap prevent damage.
Low or no DC voltage reading Inspect test station, test station may be Batteries
damaged CorrReader is powered by an internal lithium ion battery. Battery is charged by
the USB port, 5V 500mA input. The CorrReader must be powered ON to charge.
Move to another test station to confirm
The CorrReader will stay on and log continuously until the Power button is
Potentially dangerous area, disconnect and pressed to turn it off or the battery is discharged.
AC reading above 15V
follow company procedures
If the CorrReader is stored for extended periods, it may not turn on. Plug the
Turn the Stationary CorrReader ON—a CorrReader in for 24 hours and it will begin to work again. Always fully charge
No computer communication message will show on the CorrReader screen the battery before putting it in storage to prevent problems.

Use a maximum USB cable length of 2m (6’)


Technical Specification
Input Range: +/- 10 V DC AC Rejection: 50 V RMS superimposed
Input Resolution: 0.1 mV Accuracy: 0.01% DC, 0.5% AC Full Scale
Input Range: 100 V AC RMS Power: 3.6 V 4.5 Ah Lithium Ion
Input Resolution: 0.1 V AC Memory: MicroSD, FAT32 Format
Input Resistance: 11 MΩ