You are on page 1of 4

The Newtec USS0202 1+1 RF input and RF/L-band

output downconverter redundancy switching system –


UF122_D
Introduction
The Newtec USS0202 redundancy switching system is a versatile and modular system
that allows you to construct almost any possible redundancy system.
It consists of a main controller unit that can hold several switching modules.
In case more modules are needed that cannot be physically fitted into the main
controller unit, extension units can be added to house those modules.

This approach allows you to build simple 1+1 systems up to more complex N+1
systems. This system can also control groups of 1+1 or N+1 systems.
Redundancy groups are independently controlled.

Switching can be done automatically and/or manually by means of the front panel or
remote monitor and control. Although the switching system is a perfect match for
ST Engineering iDirect equipment, other non-ST Engineering iDirect equipment can be
handled as well. The definition of the switching logic and used modules is called a
“configuration”.

The most commonly used applications are documented in standardized configurations


in order to relieve you of the design process. In case a more complex system is needed,
contact our sales team (sales@idirect.net).

ST Engineering iDirect (Europe) CY NV ST Engineering iDirect Proprietary 1/4


Laarstraat 5, 9100 Sint-Niklaas, Belgium Confidentiality: Internal use only
T: +32 (0)3 780 65 00 F: +32 (0)3 780 65 49 www.newtec.eu
About this configuration: 1+1 downconverter redundancy

This configuration can be used for downconverters in a 1+1 configuration.


The redundancy switching system consists of two cross-over switches
(to allow selection of which downconverter is on-air) and alarm contact closure detection
modules that detect which downconverter raises an alarm.
The alarm contact closures output of each of the downconverters is connected by
means of an alarm cable to the alarm contact closure detection module.

When the automatic mode is activated, the redundancy system monitors the alarm
contacts of the active downconverter. When an alarm is detected, the input and output
signals are switched, effectively rerouting the input and output signals to the spare
downconverter. The fast switching ensures a minimal service interruption.

In manual control mode, the redundancy switch is controlled either by an operator


(via the front panel or the GUI) or via an external NMS, there will not be automatic
switch over on the occurrence of an alarm.

Signal flow

ST Engineering iDirect (Europe) CY NV ST Engineering iDirect Proprietary 2/4


Laarstraat 5, 9100 Sint-Niklaas, Belgium Confidentiality: Internal use only
T: +32 (0)3 780 65 00 F: +32 (0)3 780 65 49 www.newtec.eu
Wiring diagram

Back panel description – Main unit


The switching modules are labelled USS0_Mx with x the position from left to right.

• USS0_M0: Alarm contact closure detection


• USS0_M1: SMA, 50 Ohms, L-band, DC – 18 GHz
• USS0_M2: SMA, 50 Ohms, L-band, DC – 18 GHz

USS0_M0 USS0_M1 USS0_M2

ST Engineering iDirect (Europe) CY NV ST Engineering iDirect Proprietary 3/4


Laarstraat 5, 9100 Sint-Niklaas, Belgium Confidentiality: Internal use only
T: +32 (0)3 780 65 00 F: +32 (0)3 780 65 49 www.newtec.eu
Pin out Alarm Cables
The USS device can take in 2 dry alarm contacts (general and interface) from any
device ST Engineering or third party.
Below table provides a pin out of how the alarm contacts are at the USS alarm detection
module.

USS EB Alarm detection module


Contact 1: General Alarm contact
Pin 2 Common
Pin 3 Normally Closed Contact Input

Contact 2: Interface Alarm Contact


Pin 4 Common
Pin 6 Normally Closed Contact Input

Bill of material

Qty Article Number Article description


BDC redundancy switching system with configuration UF122_D
1 USS0202 redundancy switching controller
1 NTC/3410/EB dual contact closure I/O, DB9
2 NTC/3410/CG cross over, SMA, 50 Ohms, DC – 18 GHz
1 NTC/4198/AH 60 mm dummy module
Cables
2 NTC/4222/AA Alarm cable straight - mod/demod, 150 cm

Order info USS0202 with configuration UF122_D

ST Engineering iDirect (Europe) CY NV ST Engineering iDirect Proprietary 4/4


Laarstraat 5, 9100 Sint-Niklaas, Belgium Confidentiality: Internal use only
T: +32 (0)3 780 65 00 F: +32 (0)3 780 65 49 www.newtec.eu