X261 SMT Failure Summary

Quanta Confidential
QUANTA
•  NO Display
1,confirm LCD is no display or no backlight-push “Option”
2,check can Boot up from SAM card BootRom setting
3,Re-Flash BR code
1,confirm LCD is no display or no backlight-push “Option”
2,check MLB R7325/R0685 component,
3,retrun ICT/Fly Probe station to find problem component
4,take X-ray on Memory/CPU

1,confirm LCD Backlight-No


2,Check U7701 function and impedance
3.Retrun ICT/Fly Probe station to find out problem
4,check LCD backlight relate circuit
2 Quanta Confidential
QUANTA
•  No Power On
1,confirm true is no power on fail
2,Retest ICT/Fly Probe to find out problem
3,confirm ICT Error location
4,example-U4700/U7850/U4650/U4600/U0500 short

1,confirm true is no power on fail


2,Measure P-BUS CAP (C7620/C7143/C7846/C7890…..)
impedance – Low or Burn
3,confirm Cap vendor(Panasonic/NEC)

3 Quanta Confidential
QUANTA
•  Auto Shut Down

1,confirm only insert Tcon flex cause auto shut down failure
2,Retest ICT/Fly Probe to find out problem
3,confirm J8300 pin deformed?

1,confirm real auto shut down fail in boot to OS


2,return ICT/Fly Probe station to find out problem
3,reflash BR/SMC code
4,restore bundle then try again
5,verify SMC(U5000)

4 Quanta Confidential
QUANTA
•  Can’t to detect ethernet/USB device

1,confirm EU dongle function-No


2,return ICT/Fly Probe station to find out problem
3,measure U4700,CC1/CC2 impedance-Low
4,replace New U4700
5,check U7860/U7865/U4600 Location function
U7860/U7865-CC1/CC2 5V Current Limiter
U4520-High Speed MUX
U4600-Post Mirco

5 Quanta Confidential
QUANTA
•  USB3FT Super Speed test(Up/Down) Fail

1,confirm USB3.0 Up/Down side function


2,retest ICT/Fly Probe to find out problem area
3,verify U4520/U7860/U7865 function
4,Check USB related circuit component
U4520-High Speed MUX
U7860/U7865-CC1/CC2 5V Current Limiter

6 Quanta Confidential
QUANTA
•  VideoPort #3660 High Resolution Video Pattern Test Fail

1,confirm EV dongle function(Up/down side)


2,confirm external monitor function
3,retest ICT/Fly Probe to find out problem area
4,verify U2020 function-need check fixture#
5,confirm U7860/U7865 crack?

7 Quanta Confidential
QUANTA
•  Auto Mic Binary Tones Test Fail

1,confirm system fail is no sound-righ/left side??


2,retrun ICT/Fly Probe station to find out problem
3,check speak AMP damaged?
left side AMP(U6310/U6320)
Right side AMP(U6410/U6420)

8 Quanta Confidential
QUANTA
•  Can ‘t to detect ADA BOX
1,confirm Audio device function-No sound
2,check R1311(HDA_SYNC) placement

1,confirm Audio device function-No sound


2,retrun ICT/Fly Probe station to find problem
3,check J6799 RIO connector

9 Quanta Confidential
QUANTA
•  Camera #2743 S2 Enhanced Memory Test Fail

1,confirm Camera function-No function


2,return ICT/Fly probe station to find out problem
3,check U3900 chip crack?
4,replace U3900(S2 Controller) verify

10 Quanta Confidential
QUANTA
•  SensorGroup Limit with Idle test fail
1,confirm which sensor no value
2,retrun ICT/Fly Probe station to find out problem
3,check U5500(sensor alert) component
Q5560(TM0P)
Q5530(TW0P)
Q5510(TCHP)
U5580(Th0N)
U0500(TC0P/TC1C/TC2C/TCGC/TCXC/TC0F)
Trackpad(Ts0P)
Battery(TB0T/TB1T/TB2T)
RIO board U0100(Th0R)
Q5150(PECI/PCPC/PCPT)
11 Quanta Confidential
QUANTA
•  Encode/Decode Video Via Processor Graphics Engine with Cpu Load Fail

1,retest MJPEG Encode/Decode 10 loop test


2,return ICT/Fly Probe station to find out problem
3,if one time fail ,verify CPU(U0500)
4,suspect related CPU quality

12 Quanta Confidential
QUANTA
•  Can’t Power On By Battery Issue

1,Check Q6950 Pin3 to R6951 Pin1 impedance has 9.5k~10k?


Good OL / NG 9.5k~10k?
2,Check Q6950 Body diode. Good 0.5V / NG OL.
3,Check SMC SDA / SCL on D6950 Pin 1 SCL and Pin 2 SDA
impedance have low impedance.
4,Check HPM Power Gate EN Q4630 Pin3 have 3.12V

13
Quanta Confidential
QUANTA
•  OSX_checkconfig Storage #CINF device capacity fail

1,confirm no SSD detect


2,Check U8810/U8801/U8400 damaged?
3,retest ICT/Fly Probe to find out problem
4,measue SSD rail power
5,verify U8810/U8801/U8400
U8400-S1X Controller
U8801/U8810-SSD NAND

14 Quanta Confidential
QUANTA
•  Post Fail

1,confirm real Post fail same as picture


2,Check U8810/U8801/U8400/U8800 damaged
3,retest ICT/Fly Probe to find out problem
4,measue SSD rail power
5,if rework U8800 need go to ICT station do normal process
avoid MLB S/N wrong to write

15 Quanta Confidential
QUANTA
•  SSD Chamber relate issue
•  No power on www.vinafix.vn
1.  Retest ICT/SVT
2.  Pass !retest Chamber
3.  Fail follow normal process

•  Memory issue
1.  OP will records the fail address
2.  Use DiMMTool decode location
3.  Can see the memory issue FA SOP
16 Quanta Confidential
QUANTA
Thanks!!