You are on page 1of 6

Intelligent (Automatic Mapping) PQWT

Geophysical Prospecting Water Detector


PQWT-TC Series Water Detector Character
Water Detectir Cast Share
• The independent-developed PQWT geologi­ Hunan Puqi Geologic Exploration Equipment Institute
cal prospecting system can automatically
form curve graphs and profile maps.
• Store 999 measuring lines data and record
999 measuring points data each line.
• 7 inch HD touch screen, alloy electric bar.
• Easy operation, convenient portable, only 1 -
2 people for operation. PQWT-TC Series Automatic Form Profile Map In The Instrument

Profile Map/Curve Graph


Hot

For our users’ better service with more success drill­


ing well, our institute have"Puqi institute geological
prospecting water detector communication platform".
Our senior engineer, geologist professor will give the
specialized suggestion.

PQWT-TC Series Automatic Form Profile Map In The Instrument Technical Parameters

Website www.pqwtcs.com

Address: Building A16, Jiahai Industrial Park, No. 1318 Zhongqing Road.Kaifu District,

Changsha, Hunan, China 410000


Mobile(Whatsapp):+86 18817121518
Intelligent Automatic Mapping
Geophysical Prospecting Water Detector

Water Detector Case Stare


QWT-TC300 PQWT-TC150 1 PQW T-TC Water Detector Case Share

|T| Most Competitive Price

|T| Top Quality


Contents
|T| High Efficiency Development history and practicalapplication of geophysical prospecting
instrument for natural electric field...................................................................................... (1)
|T] Anti-interference Ability

[TL»SO9001: 2008 Certification The Principle and Research of Natural Electric Geophysical Prospecting
lnstrument(Underground water detector)............................................................................ (4)

Case share...........................................................................................................................(9)

QWT-TC500

• PQWT-TC700 / » PQWT-TC900/ • PQWT-TC1200X


Measurement Depth :600 Meters Measurement Depth: 1200 Meters Measurement Depth :1500 Meters
Case analysis A Key To Map Leading The Future A Key To Map Leading The Future Case analysis

At present, methods of geophysical prospecting for different frequency of the electric field component of
water are NMR, natural electric (magnetic) field the law of change to study the electrical changes of
method and high density resistivity method, induced underground electrical cross-section, to solve the
Development history and practical application of polarization (IP) and other method. This paper below geological problem of an alternating current
geophysical prospecting instrument for natural electric field will focus on the introduction of the use of natural water exploration method. Because the electric field
field method in finding water. The basic principle of measured by this method is the electrical component of
natural electric field method is through the observation the ground electromagnetic field, so it's called the
Hunan Puqi Geologic Exploration Equipment Institute of natural field existence, to study the geological natural electrical field; and because we selected
structure, find useful mineral resources, water several or scores of low frequency electric field
The development history of human society is the geology , electrical prospecting has become one of resources. It is a kind of geophysical exploration components as the measurement parameters, we
history of geological work, from the ancient the most effective means of investigation that cannot method to solve engineering, environment, disaster, selected the frequency selection, so called the
Paleolithic age, pottery age, to the bronze and iron water and other geological problems. The natural selection method, total called natural electric field
be replaced. In the field of archaeology, environmental
age, have carried out long geological work. Ancestors electric field geophysical instrument is a kind of natural frequency selection method. The following is the
and geological disaster investigation, the electrical
have made a great contribution in this respect. The electric field as the field source to the underground natural electric field frequency selection method and
method is an effective way. The electrical method is
geological work in modern China has made rock ore (groundwater) electrical difference based on the natural electric field geophysical instrument
ofvarious kinds, wide application field, because of the
preliminary achievements since twentieth century. the measurement of natural earth electromagnetic field principle analysis.
limited space, it is difficult to accurately express the
In January 1912, the provisional government of in a number of different frequencies of electromagnetic 1 .The basic principle of natural electric
huge progress of electrical prospecting in China.
Nanjing set up the minerals department of the field changes in the law to study the ground field and field frequency selection method.
ministry industry, under which there was the General picture of development different of the geological body of the abnormalities to
The field of the natural electric field is the geomagnetic
geological department and was presided over by From early 50s to mid-50s is a start-up stage of new solve the geological problems of a kind of electrical
field (radio emission field or AC electric field). The field
Zhang Hongzhao. China electrical method entrepreneurship and exploration equipment. It's small size, light weight,
distributed in the ground far from the field source can
In 1913, the government of Beijing set up a developed and perfected the natural electric field portable to carry; no artificial electric filed source, the
be regarded as a plane wave whose distribution is
Geological Institute, Zhang Hongzhao as the director, method, resistivity profiling and sounding method. two man can work; exploration depth, high efficiency; approximately perpendicular to the ground. The
and in 1916, trained the first batch of geological And soon formed a productive forces in mineral after use of frequency selection device, anti­ change of the field is subject to Maxwell equation set.
exploration backbone, a total of 21 people. resource exploration. Method of natural electric field interference ability strong, equivalent to 10 different
In 1916, the geological research institute was become shallow ore exploration conducting rapid and electrode distance symmetrical quadrupole apparent
changed to a geological survey station, and Ding economical census means. The electrical sounding resistivity profile measurement results; to overcome
Wenjiang was appointed director of the geological the DC method long-distance cable, equipment, heavy In equation 1: Ps represents the AC resistivity, f is the
method has become an important method of coalfield
survey. and other shortcomings, to work in a smaller range, operating frequency, Hy andEx,is magnetic filed
resources exploration. At the same time, a variety of
After 1942, the mineral surveying and surveying office especially adapted to the rapid mountain survey and component and electric field component respectively.
device resistivity profiling method has also been
was established, and Xie Jiarong was appointed urban geophysical jobs. Natural electric field According to the attenuation characteristics of the
widely test. Among them, the combined section
director. geophysical instrument is mainly used in the principle plane electromagnetic wave propagating in the
device becomes the most effective means to
of natural electric field frequency selection method. formation, the penetration depth of the electromagnetic
After the victory of the war against Japan in 1945, it determine the position of projection of various
Natural electric field frequency selection method, short wave in the medium is:
was renamed the central geological survey of the electrical bodies and the factors of occurrence. By
Ministry of Economic Affairs (held in Taiwan so far). name is frequency selection method. It is based on the 8 = 503.3pf (2)
60s, researchers in China began to study
Before the founding of new China, the personnel electrical difference of natural earth electromagnetic
electromagnetic induction methods characterized by In the equation 2: 8 is the penetration depth. It can be
engaged in geological and mineral exploration is a total field ( frequency 0~30kHz) in several different
absolute measurement. By 70s, relative seen from the above, the penetration depth of
of 290 people, 14 rigs. frequencies of electromagnetic field changes in the law
measurements had been made, and great progress electromagnetic waves and frequency, resistivity.
After the founding of new China, China's geological to study the underground ground field changes, to
was made in 80s. By 90s, the introduction of digital, When the frequency is constant, the higher the
work developed rapidly, experienced the prosperity solve the geological problems of an alternating current
graphic and image technology made the electrical resistivity, the greater the penetration depth, when the
brought by arduous pioneering work, but also suffered exploration method. The method used by the
prospecting technology develop by leaps and resistivity is constant, the lower the frequency, the
difficulties and setbacks. However, based on firm and instrument called natural electric field frequency
greater the penetration depth. Therefore, by changing
bounds, and gradually formed the integrated design, selection geophysical survey instrument. Natural
indomitable hard work and dedication of geologists, the operating frequency can achieve the purpose of
both theory, technology method, application scope, acquisition, processing, interpretation and electric field frequency selection geophysical new changing the depth. Because the magnetic field
application level and application effect have made submission of results. Since twenty-first Century the method for short is the natural electric field frequency component is bascially stable in the small area of the
great progress. Nowadays China already has all the intelligent degree of the geological exploration selection method or frequency selection method, is consent area, it can be regarded as a constant, so the
methods and techniques of geophysical exploration in instrument to further improve the non-professional use of ground electromagnetic field as a workplace qualitative relationship between the electric field
the world, which in some aspects has reached the personnel without hydrogeological basis especially source to the underground rock, ore resistivity component and the resistivity can be used to judge the
international advanced level. In all kinds of prospecting individual households can also carry out the basic difference based on the ground to measure the earth's high and low resistance characteristics of the
like mineral resources, hydrology and engineering drilling operation, simple analysis. electromagnetic field generated several ( or scores of) geological body.

01 PAGE PAGE 02
Case analysis A Key To Map Leading The Future A Key To Map Leading The Future Case analysis

The instrument measure the frequency of the (4) Using the natural frequency Wn to convert the
electromagnetism. The spectrum of the earth's analog low-pass filter prototype into analog low-
pass,high-pass,bandpass, band-stop filter, can be
electromagnetic field is quite wide, from 0.001 Hz to The Principle and Research of Natural Electric Geophysical
used function IpZIp, IpZhp, IpZbp, IpZbs;
106 Hz. However, according to the actual geological
(5) The impulse response invariant method or the Prospecting Instrument (Underground water detector)
problems, you can use 15.7Hz~2520Hz frequency of
bilinear transformation method is used to convert the
the 10 frequency, the frequency interval in the analog filter into a digital filter, which is realized by the Hunan Puqi Geologic Exploration Equipment InstituteQQ: 2170844318
logarithmic coordinate paper evenly distributed function imp invar and i bill lea r respectively. Abstract:
achieve the purpose of detecting different depth. The article is talk about the basic theoretical and the design principle of Natural Electric Geophysical Prospecting Instrument. According to the
(6) The design of the low-pass Chebyshevl type theory of electromagnetic field, frequency selection is designed to accept multiple frequency earth electric audio signal, to make qualitative
Practice that: calculated by the theoretical formula of digital filter: the design needs to limit the passband observation scheme for the electrical structure of the underground geological body. The design utilize the weak signal detection technology, after
amplification, filtering, frequency detection, integration, signal condition, the earth electric audio signal is conversed into digital signals for
the depth than the actual depth, so to multiply a upper limit critical frequency wp, stop band critical analysis.
The instrument can observe multi-frequency of the electric field signal, use a variety of Reliable technology in hardware design and software
correction factor, generally take 0.3 to 0.5. filter frequency was, in the passband maximum
development, so the anti-jamming capability and system stability have been strengthened. It is utilize multi-channel & multi-mode data acquisition
attenuation, stop band within the minimum attenuation in the instrument, the collection data is analyzed and processed automatically. The data are saved then the curve graph is drawn in real time. We
can found the broken zone by the curve quickly.
2. The basic principle of natural electric Through comparative analysis to field work, the natural electric field frequency selective instrument is available to reflect the geological
Natural electric field geophysical prospecting information within a certain depth of the underground, it is apply for geological mineral investigation, geological engineering prospection and water
field geophysical prospecting instrument resources detection.
instrument electric circuit diagram shown in Figure 1.
According to the natural electric field frequency Key words: Natural electric field/Natural magnetic field/Natural Electric Geophysical Prospecting Instrument
Mainly include input amplification, attenuation level,
selection method design and manufacture of
50Hz filter, frequency selection network, linear The inner electrical and electric field Working Principle
instrument called natural electric field geophysical amplification, detection, display, power and other
distribution of the Earth Natural electric audio signal measurement is a passive
instrument, for short is natural electric field frequency modules. source in electromagnetic profile method which is
selection device or frequency selection instrument for There are natural variable and stable electric field in proposed by China in the late 70s, 20th century. It is
the surface of the Earth. The variable electric field is also known as "Audio earth electric field method",
geological exploration work. It includes acquisition,
generated by a variety of currents outside the Earth "Frequency selection of earth electric field method». it
filtering, frequency selection, amplification, has strong ability to distinguish good conductor
which are distributed in vast area of the surface of the
conversion and so on. The filter circuit is the most medium, the exploration depth is able to reach 2 km,
earth, it is generally with a small gradient. and the working principle is similar to the natural field
critical, because it includes a simulation filter theory,
The stable natural electric field is mainly produced by source electromagnetic sounding method , we utilize
the current analog filter theory and design methods the solar wind of the universe, lightning and other
the ore body, groundwater and several of water
have been developed quite mature, and there are Natural electric field geophysical natural electromagnetic field signal which shoot into
systems, it is distributed in partial areas, generally with the Earth , as the stimulate field source, use electrode
some typical analog filters for our choice, such as prospecting instrument practical a large gradient. A variety of variable natural global or into the ground to measure the natural electric field on
Butter worth filter Device, Chebyshew filter, elliptical partial electric field is known as the earth electric field. the surface of the N different frequency electric field
application component.
filter, Bessel filter, etc., these typical filters have their The earth electric field is originated from the natural
Natural electric field geophysical prospecting Natural field source is also called once field, the
own characteristics. electricity, it is Induced electric field caused by the electromagnetic field is plane electromagnetic wave,
instrument is widely used in water detection, mining
With MATLAB for a typical digital filter design, the electricity in the crust and the inner earth, different geo which shoot perpendicularly into the medium ground,
locator, prospecting geothermal exploration and so electric changes have different electricity source. The the earth will produce induction electromagnetic field,
general steps are as follows:
on. Therefore, the natural electric field geophysical field source of geo electric diurnal variation is the which has the same frequency as once field.
(1) According to certain rules will be given the digital Research Shows
prospecting instrument is one kind of academic name. current system which distributed in the ionosphere.
filter technical indicators into analog low-pass filter The low frequency current system of geo electric 1) Observation on the surface of the earth for the
From a professional field of view, natural electric field
strength of the electric field bring information in a
technical indicators: diurnal variation is mainly distributed in the sky of
geophysical prospecting instrument should belong to certain depth of the earth's electrical distribution.
(2) According to the converted technical indicators, geological prospecting instruments of the geophysical middle and low latitudes, the height is about 300 km. 2) The different frequencies of electric field strength
the filter order selection function is used to determine The field source of low frequency geo electric variation also reflects the earth's electrical structure of different
instrument. From the practical application field of
is the lightning produced by the troposphere, which is depths.
the minimum order number N and the natural view, can be called mining locator , water detector ,
mainly distributed in the sky, near the equator 8 km. The resistivity is in-available to be calculated if we
frequency Wn, According to the type of the selected prospecting mineral instrument, engineering surveyor, only observe the strength of electric field, so
analog low-pass filter: buttord, eheblord, The distribution of the electric field on the ground is not
geothermal detector, water equipment, prospecting qualitative analysis is available, quantitative analysis
only depends on the external field source but also is in-available.
chebZord, ellipord, etc. equipment, exploration equipment, gold .Mine and
depends on the electrical structure of the crust and 4) We observe multiple frequency electric field values
(3) Using the minimum order of N to produce analog other minerals. From the perspective of measuring the on the surface. Since only the electric field value be
mantle. Therefore, the application for research geo
filter prototype, analog low-pass filter to create the source field to classify, can also be called natural electric field not only help us to research the electrical observed without magnetic field value, it is not
necessary to build the field source manually, so the
function are: buttap, eheblap, ehebZap, ellipap, electric field instrument, audio field meter, earth audio structure of the crust and mantle, but also help us to instrument can be portable and carry out fast
besselap.ect. and so on. detect minerals, groundwater and other resources. observation speed.
03 page PAGE 04
Case analysis A Key To Map Leading The Future A Key To Map Leading The Future Case analysis

Machine design - Hardware components Besides, the useful weak signal may be overwhelmed F2-I Fa-l Fm-1 The low filter cutoff the transfer function is:
by the noise voltage carried by these noise: F=Fi+ V, > A. .
The work flow of Natural electric field electric Ki K1K2 K1K2' • 'Km - 1 A(.s) = ------------------
instrument which designed by Hunan Puqi Geologic 1) The noise generated by the recombination and V 11.
It can be seen from the above formula that the Pre-class sCX -'C A,
Exploration Equipment Institute is as below. reproduction of the semiconductor carriers in the has more greater influence on the total noise figure, if
1) Collect the weak signal by the measure electrode. electronic circuit, The high filter cutoff frequency is: Fu=1/2ttR1C2
the first stage amplification factor K1 is big enough, the
2) The signal through the RF interference suppression Circuit design follows the principle of filtering while
2) The flicker noise affected by the semiconductor total noise figure F mainly depends on the first level
circuit, into the impedance conversion circuit, and then
surface state,3) The quantum noise of light .Besides noise figure F1. processing, to ensure the effective signal
enter the preamplifier circuit for the First level
to these noises, there are some human disturbances Therefore, in the design of low noise system for weak amplification, correct extraction and the maximize
amplification. signal detection, we must ensure that the first level of
3) Then the signal enter the Double T-limiting circuit, and nature disturbances. These disturbances and inhibition for noise & interference signals.
the noise figure is small enough, so the design of the
trap wave for 50Hz frequency and its third harmonic noise which come from the outside of the 4) Shielding and grounding technology:
preamplifier is essential. Besides, to the multi-level
notch. measurement system can be minimized by the amplification, different arrangement means different Shield means to install the amplifier in the shield shell,
4) The signal through the filter circuit into Second level method of electromagnetic shielding in principle. total noise figure, the best way is to set smaller noise the shield shell should bring a certain potential to
amplifier circuit. However, to eliminate these interference and noise, figure to the Pre-class. prevent the current flow through unbalanced Source
5) Then signal through the filter circuit again for the
is not an easy task in practical work. Since the value 2) Remove the frequency interference: Since the source
third amplification. impedance, thus eliminate the input noise voltage,
of noise is unavailable to be predicted, it cannot be field is natural , the detected signal is very weak, in
6) And then filter. At this point the signal through the especially the impact of common mode noise.
defined by an analytic function. order to effectively suppress the interference on the
three-level amplification, the useful signal has been Grounding is available to eliminate the noise caused
stable enough. So Hunan Puqi Geologic Exploration Equipment audio signal of earth electromagnetic field which caused
by the circuit loop through the ground resistance, to
7) At this time the signal is divided into two lines for Institute use probability and statistical methods to by 50Hz frequency and its third harmonic , in the signal
avoid noise coupling in the ground loop. In weak signal
analysis. One way is to be simulation filter analysis: describe. The statistical approach focuses on the channel, we utilize Two-stage double-T notch circuit
through the frequency selection filter circuit, detection detection, since the useful signal is extremely weak,
quantitative characteristics of the sample, rather than (50Hz, 150Hz),notch depth of -40db, width of 10Hz, to
circuit, integrated circuit, come into AD acquisition, and the magnitude is usually lower than UV, it is easy to be
the characteristics of individual elements. In the case maximize suppress interference frequency signal from
change into digital signals. Another way is digital overwhelmed by strong noise, and amplifying circuit is
of random noise, the sample may consist of a large the hardware, to ensure that the collected signal will not
filtering analysis: through the signal conditioning circuit designed to utilize reasonable shield and grounding
number of consecutive collected values from its be submerged by 50Hz and its harmonics signal.
directly into the AD high-speed acquisition for digital
waveform. Commonly, we use probabilities and technology, to minimize the external Interference,
filtering analysis. In practice, we found that the effect of filtering is very
statistical methods such as probability density good. It carry out maximize shield for 50Hz frequency coupling and other noise. Therefore, the shielding and
Hardware composition diagram
function, mathematical expectation value, variance, interference and its third harmonic interference, ensure grounding technology is very important to design for
RFI Suppression Circuit -> Impedance Change ->
Preamplifier-> 50Hz Notch -> 150Hz Notch ^Second- mean square value, correlation function and other the reliability in data collection even with strong high-quality and low-noise amplifier.
level amplification->Three-level amplification eigenvalues. frequency interference. 1. Ground technology
Simulation analysis -> frequency selection ->wave The signal & noise ratio of the instrument is improved According to the purpose, it can be divided into two
3) Multi - level active filter network
detection -> integration -> 32-bit high-speed processor. by the following key point: kinds of grounding: protection grounding and signal
Digital analysis -> signal conditioning circuit -> 32-bit 1) Low noise pre-amplifier circuit: In order to detect grounding, grounding in low noise amplifier is mainly
high-speed processor.
the weak electric signal of the natural electric field,
As a modern electronic equipment, the circuit design refers to signal grounding. The purpose of grounding is
the amplifier is required to have very low noise. Low
follow the features of a modular, Plate up, utilize user- to minimize the impedance of the amplifier which
noise amplifier is extremely important to improve the
friendly interactive interface, bus technology, 32-bit connected to each other by the ground, thereby reduce
high-speed processor etc. All the circuit modules capacity of the sensor including measure weak
The transfer function is: the impact to the amplifier which caused by the ground
control, data acquisition control, transmission and signal, the range of measurement and sensitivity.
current. Signal ground can be divided into two ways:
communication are carried out by Bus technology In order to achieve the best noise characteristics, we
A(s) = -^ =----------------- —------------------ single- point grounding and multi-point grounding.
which basically based on the central processing unit. use signal to noise ratio and the equivalent input V'm 1 + (3 - Al | ) ( )‘
Machine design - noise and interference 1.1 Series single-point grounding
noise voltage to design all levels of the amplifier of
suppression the system. When we design weak signal detection The ground circuit interference of signal in series
Because the signal change of the earth's system. single-point grounding way is shown as below, there is
electromagnetic field is very weak, reach UV or even NV For the multi-stage amplifier cascade system, we set a certain impedance in the wire. In the picture, UA is
level, noise and interference is the main contradiction to the potential of point A, which is the zero potential
the noise coefficients of all levels amplifiers as F1, F2
the detection of this weak signal, because the material is
..., FM, and the generated noise power is P1, P2, ..., reference in circuit A; UB is the potential of point B,
always composed of charged molecules and atoms, and
PM, and the power gain is K1, K2, ..., KM ,then the which is the zero potential reference in circuit B; UC is
the object is always present under certain temperature
conditions. The thermal disturbances of charged total noise figure F of the whole system can be the potential of point C, which is the zero potential
particles produce thermal noise. expressed by the Frisian Formula. reference in circuit.
05 page PAGE 06
Case analysis A Key To Map Leading The Future A Key To Map Leading The Future Case analysis

The ground current is independent of each other, do This is normal ground connection, it has two ground 2.2 Shield principle for low noise amplifier
not interfere each other, it is a good way which is used points: source ground and amplifier ground, Double As shown in the following circle diagram, it is shown
commonly. But this way requires a lot of ground core signal line is utilized for shield cable. There will be a weak signal through the amplifier:
connection, it is more cumbersome, and at high great disturbance, if the common mode source (noise
frequencies, noise coupling will be caused by the source) is added to the input port. (The noise source is
mutual inductance between the ground circuits. When caused by the potential difference between the source
the frequency increases, especially when the length resistance and the amplifier ground point) In this case
of the ground line is Odd times as 1/4 wavelength, the we should consider the floating grounding way. It is
ground impedance becomes high, and the ground line common to add a resistor at the source ground. As is
Illustration of series single-point grounding change into antenna and radiate the signal outward.
(a) Correct cornedtcn
Therefore, this grounding method applies to circuits
below several megahertz. shield cover
The figure shows
UA= (11+12+13) R1;
UB= (11+12+13) R1+(12+13) R2;
UC= (11+12+13) R1+ (12+13) R2+I3R3;
As we known from the formula UA^UB^UC
7777
UA is related to currents 12 and 13 of the circuits B , C;
Floating grounding Figure (b) Wrong connection 1
UB is related to the currents 11, I3 of circuit A ,C and
The ground loop signal is caused by the connection of
resistors R1, R2 ; UC is related to the currents 11, I2 of
more than one ground point in the system, while the
circuits A,B and resistors R1, R2, their ground currents Multi-point grounding is as shown: floating area eliminates multiple ground point, that is,
interfere with each other. Above only consider of the the shield sheet of the source and signal lines is
In order to reduce the ground impedance, the
resistance for the ground connection, if we consider of grounded only at one point in the source of the signal,
simplest way is to make the circuit near the ground,
this is the best way to reduce the sense of interference,
the inductance L1, L2, L3, then it will be more avoid using long connection line on ground, which is to avoid the shield wire contact with more than one
complicated interference between circuits A, B, C. called Multi-point grounding. In comer, weak circuit grounding system.
Therefore, this grounding method is unreasonable in are close to ground, ground connection is shorter, and 2. Shielding technology
low-noise circuits. But it will be utilized in general for ground impedance is low. In general, when the 3) Multi - level active filter network
Shield means the method we use containers which
simple. We do not use it here frequency is less than 1MHz, we utilize single-point The instrument is developed several times from the
made of low-resistance materials magnetic materials to
grounding way; when the frequency between 1- surround the circuit that need to be isolated. Shield is hardware to the software, through different dates,
3) Multi - level active filter network
10MHz, in the condition of Single-point grounding, the closely related to grounding. To reach good shielding different periods, different operators in different
Parallel single-point grounding is as shown in the figure. affection, we need not only careful consideration of the regions and use electromagnetic, DC, high-density
total length of the ground must not exceed 1/20 of the
shielding, but also attention to the grounding method. instrument and other instruments for experimental
wave length ; otherwise we use multi-point
Usually, interference can be overcome basically by comparison, the reading stability of the instrument has
grounding, when the frequency is higher than 10MHz,
reasonable shielding and grounding methods. reached high level, it is available to reflect a certain
we should utilize multi-point grounding .
2.1 Classification of Shields degree of ground resistivity information, for analysis
1.4. Floating grounding The shield can be divided into following categories: and evaluation. The whole system of the device is
Electrostatic shielding - to prevent electrostatic simple, lightweight, fast and with high efficiency, carry
Floating grounding is as shown in the figure. coupling interference; out rapid scan work in a large area of surface to
Electromagnetic shielding is mainly used for high determine the investigation area, it has unique
frequency (f 1 KHz) or high impedance (R 1KQ) advantage to improve work efficiency. The instrument
occasions. We use low-resistance metal materials, such will continue to be improved on the circuit as well as
as aluminum, copper, etc., utilize the internal flow in the software, increase the acquisition channel of the
metal to prevent the interference of alternating instrument, and optimize the data integration from the
In this case, the reference potentials of the three electromagnetic fields; analog channel to the data channel.
circuits are UA = 11R1, UB = I2R2, UC = I3R3. Without Magnetic field shield is mainly used for low frequency or In 2017 we achieved the goal that the instrument
small impedance. We use high permeability materials to automatically draw 3D map, completely out of the
considering the mutual inductance between them, the
prevent magnetic induction, such as iron-nickel situation of draw with professional graphics software
ground potential of each circuit is only related to the
magnetic alloy, manganese tour alloy and twisted pair on computer, mapping with one-button in a second
ground current and ground impedance of the circuit , line. We also use battery of the pre-amplifier as a time device is realized by us. We will continue to
and has nothing to do with other circuits, separate power supply and other methods. innovate and make the equipment more intelligent.
07 page PAGE 08

You might also like