Preparation:
1. Make sure if there is a leakage problem in pipes. Take the fire pipes for
example, it is necessary to check the pipeline pressure holding or decreasing
pressure of the pressure meter in the pump station.
2. Search and check any unknown water flow around the pipe well.
3. Observe if there are any land subsidence around the pipes and if there
abnormal any wetlands.
4. Use the detector to check the valve and abnormal leaking noise of the
exposed pipes. It could be mainly checked if there are any signs of the
abnormal leaking noise.
5. Use the underground metal pipe detector to find the direction of the pipes, if
the direction is unknown.
Instrument operation:
【General Detection】 which is mainly used to check the indoor pipeline water
leakage in large areas.
(1) Click the "Indoor" then choose the "General Detection".
(2) Turn on the knob switch to receive sound, and pay attention to the sound
volume in the headphone and observe the spectrum change on the screen.
(3) When the spectrum on the instrument 'screen is high and the sound in the
headset is significantly increased, the area can be identified as a suspected
leakage area and marked.
Notice:
1. It's forbidden to put the sensor into the water, and please put the sensor
gently.
2. It's forbidden to use in flammable and explosive areas such as gasoline and
natural gas.
3. If it is for outdoor pipeline leak detection, please select the corresponding
detection parameters according to the actual environment.
4. If the instrument is not used for a long time, please charge it once a month at
least.
5. When detecting the area like soft soil or a lawn, it is better to use the sensor
to connect to the sound pole and insert it into the soil.