You are on page 1of 2

07RN8-F 450/750 V

PUMP CABLE
In line with EN 50525-2-21, IEC 60 245

Multi-core flexible, water resistant, thermosetting compound


insulated and sheathed cables

CONSTRUCTION
Conductors: Bare annealed copper conductor, flexible, class 5 in accordance IEC 60228.
Insulation: Ethylene-Propylene Rubber thermosetting compound.
Sheath: Double layer, thermosetting compound.
Inner layer Ethylene-Propylene Rubber (EPR) compound.
Outer layer Chlorinated Polyethylene (CPE) heavy duty, flame retardant
compound.
Colour of sheath: Blue or other colours available upon request.
Core identification: According to HD 308 S2.
Test voltage 50Hz: 2500V
Flame propagation: IEC 60332-1-2.
Minimum bending radius: For cable diameter D (mm)
D<8 8 < D < 12 12 < D < 20
For fixed installation: 3D 3D 4D
At inlet of portable appliance or
mobile equipment. No 4D 4D 5D
mechanical load on cable
Under mechanical load 6D 6D 6D

FEATURES
 Maximum conductor operating temperature: +90°C
 Lowest ambient temperature for fixed installation: -40°C
 Maximum short-circuit conductor temperature: +250°C
 Pulling strength: not exceeding 15 N/mm2
 Excellent water resistant up to 100 m water depth
 Excellent flexibility
 Ozone, sun, weather, heat resistant
 Ink jet or indent printed for easy identification

TELE-FONIKA Kable Sp. z o.o. S.K.A.


www.tfkable.com
07RN8-F 450/750 V
PUMP CABLE
In line with EN 50525-2-21, IEC 60 245

APPLICATIONS
 Designed for use in deep water up to 100 m.
 The cables can be used in industrial water, ground water and sea water.
 Heavy duty flexible cables are suited for use under medium mechanical stress especially for the connection of
submersible motor pumps in site drainage construction. For maximum water temperature up to 400C.
 Other industrial applications

Standard length cable packing 500 or 1000 m on drums. Other forms of packaging are available on request.

Number and Maximum Nominal Nominal Approx. Approximate Maximum Current-


cross- diameter thickness thickness Outer net conductor currying
sectional of wires of insulation of double Diameter weight resistance at capacity*
area of layer jacket temperature
conductor 20°C
2
n x mm mm mm mm mm kg/km Ω/km A

4x6+2x1,5 0,31 1,0 1,0+1,5 21,4 588 3,30 50


7x6+2x1,5 0,31 1,0 1,0+1,5 22,4 806 3,30 55
4x10+2x1,5 0,41 1,2 2,2+3,2 26,8 1052 1,91 67
4x16+2x1,5 0,41 1,2 2,2+3,2 29,6 1371 1,21 91
4x25+2x1,5 0,41 1,4 2,2+3,2 33,4 1880 0,780 121
4x35+2x1,5 0,41 1,4 2,2+3,4 36,2 2347 0,554 149
4x50+2x1,5 0,41 1,6 2,2+3,4 40,3 3000 0,386 183
0 0
* At 30 C in air for 85 C conductor temperature

All the information contained in this document - including tables and diagrams - is given in good faith and believed to be correct at
the time of publication. The information does not constitute a warranty nor representation for which TELE-FONIKA Kable assumes
legal responsibility. TELE-FONIKA Kable reserves rights to introduce changes to the document at any time.

TELE-FONIKA Kable Sp. z o.o. S.K.A.


www.tfkable.com

You might also like