You are on page 1of 6
HEATING SBU Cooling & Hering Dion THERMAX ‘Thermopac-TPDi ‘Thermopac Excel-TPD THERMOPAC” Oil / Gas Fired Thermic Fluid Heater at low operating pressure |OPAC - TPDi with Integral APH e reliable and efficient system for high process temperatures Thermic fluid heating has replaced electric and steam heating in industries globally. Thermax pioneered the concept in india way backin 1971 with its Thermopac. For decades now, Thermopacs are recognised everywhere as superior heat sources and productivity enhancers. Product offering + Fuel - Heavy Oil, Light Oil and Gas + Capacity - 0.4 to 2.5 million kcal/ hr + Operating temperature- 280°C Product highlights + Automatic control for maintaining predetermined thermic fluid temperature + High system efficiency -87% + Centrifugal pump ensures uniform circulation, thus preventing overheating of thermic fluid + Suitable up to 300°C (bulk oil temperature) with system and equipment modifications + Internal APH (between two jackets) ensures unit surface temperature below 55°C Options available + Horizontal orientation + Separate deaerators and common expansion tank for multiple unit installations + High temperature options up to 380°C + Complete heater house and accessories on turnkey basis, Controls and safeties + Low thermic fluid flow cut-off + High thermic uid outlet temperature cut-off + Precise thermic fluid temperature control + Low level cut-off in deaerator tank + High stack temperature cut-off + Safety valve for protection against high pressure THERMOPAC EXCEL - TPD The assurance of the highest efficiency in its class Options available + Horizontal Orientation + Separate deaerators and common expansion tank for multiple unit installations + High temperature options up to 380°C + Complete heater house and accessories on turnkey basis Product offering + Fuel - Light Oil,Heavy Oil & Gas + Capacity - 1 to 2.5 million kcal/hr + Operating Temperature - 280 °C Product highlights + Specially designed and patented air preheater = Combination of cross and parallel flow arrangement of air and fiue gas circuit + Modular design of the unit ensures quick assembly and ‘compact layout + Designed and verified by modern tools like CFD and FEA Descrstion unit Poi To Alotgral APH) (External APH) Foal Fo NG FONG Thermal ficiency" a7 865 15 Fue consumption _kgihr/Nmehr 298 340281321 “Efcieney considered on NOV Bass i Thermopac Excel TPD comes with a non- corrosive ar pre-heater with a hybrid cross and counter flow design that has been oa oes validated with extensive CFD analysis. 'v | + Airisintroduced in the intermediate flu «gas zone which maximizes heat and reduces stack temperature - + Diverter damperin flue gas line online cleaning ofthe APH and use of only ‘one module while the otheris under leaning + Modular APH helps to maintain efficiency even under part load conditions + No risk of dew point corrosion asthe configuration ensures optimum metal an [APH rand fe gs iret CFD Analisis temperatures ~ THERMOPAC - TPCM Product offering + Fuel - Heavy Oil, Natural Gas & LPG + Capacity 0.1 to 0.2 milion kcalfhr + Operating temperature - 280°C Product highlights + Aptly designed for mid size temperature and very low heating requirements + Imported monobloc burner + Ideal for the packaging, colour printing, pharmaceutical and leather industries + Compact and reliable Technical specifications - TPCM series Capa kealfor Maximum Outlet temperature a 280'C/300"C (Optional) ThertmicFuid Flow ate mfr 5 10 ‘Thermic fluid temperature rise i 2 2 Firing System Type Monobioc Burner Light Up By High Voltage Spark Unit efficiency ‘As per BS 845-Part|(NCV Basis) so % 8 Natural Gas/LPG ® 865; Fuel Consumption Hsp sft " Natural Gas eve “ 2 ee mfr 5 8 ‘Total Connected Load Hs kw. 29 29 NGas/tPc kw. 28 28 ‘Overall Dimensions & Weight Lawak m 09x15x23 1.03% 1.6425 Dry Weight io 1200 1500 Chimney Top Diameter mm 150 200 Engineered for reliability + Designed according to DIN 4754, to ensure longer life of heater and thermic fluid + Adequate furnace volume and heat transfer surface ensure higher thermal efficiency + Pre-wired and pre-assembled for quick and easy installation Compact Deaerator- cum-Expansion Tank + Requiring less space, it comes with a buffer vessel to prevent cooling of hot oil coming from the process +The tangential thermic fluid entry in the deaerator ensures optimal deaeration Manufacturing excellence — O O Fay arses Typical P & I diagram for thermic fluid heating system Film temperature - 7, Metal wal Bulk temperature-T,, | | temperature -T, Thermic fluid flowing thro a tube T., >T,>T, Vent Sanson ° tank e Hwy Sag Themie fluid inlet Deaertr buter tank vessel ‘Thermic——+ ¢ haat : ae ron o£ De-erator tank mao tal Outlet temp. hi -@ Feet on eee” eco] ra uate sit ae a 4 A) @ TE pumo L Fuel pump mu ‘Thermic fluid Se p< el [> cainy ost Technical specifications - TPDi series Description Unit ‘TPDi-04 ‘TPDI-06 capacity vale 400000600000 Maximum Outlet temperature c Thermic i fw rte mij 2 36 Thermic hid temperature ise c 3 2 Fring System Type Burner Light Up Unitefceney Hsoy/LDOjFO % Naural Gas/.PG x Fuel Consumption #50 kale a 66 too he 4 63 fo tafe “8 n Natura cas whe 5s 2 wc Nhe 19 28 Total Connected Load #s0/100 ww 80 105 Fo. ww no 165 Nasftec kw 80 105 Overall Dimension & Weight LxWxH m Dey Weight i 2100 260 Chimney Top Diameter mm 250, 25 Technical specifications - TPD series Description Unie 170-10 Capacity eal 000000 Maximum ute semperture “Ther i lw rate fhe « ‘heen Fid temperature rise Fring System pe Unitefcency Hs0 /L00/#0 x Natural as / PG x Fue Consumption 80 aie 1035 10 ight 1065 0. yh ins Natural cas Ne 293) 6 Noe 44) Total Connected Load sp /L00 kw 160 cS kw 250 fevita ew 155 ‘Overall Dimensions & Weight Laws m 42x3.0x44 Dry Weight 6 4000 hire Top Dieter mm 450 ‘THERMAX LIMITED Heating SBU, C&H Division 1-13, M.LD.C. Industrial Area, B.D. Aga Road, Cinchwad, Pune - 411019, INDIA Fax: 491 -20 - 27472049 E-mail heating.enquiies@termaxincia.com ‘www. thormaxindla.com THERMAX Tals +91 - 20 - 27470436, 2747596%/ 42, 66122100 V¥ ToH10 ‘OHS OH20TPDI2S “yo00,000 1500000 2,000,000 2.500.000, 280°C)300%C(Optonal 60 90 120 150 35 35 35 35 Pressure let By High Voltage Spark ‘As per BS 845. PartI(NCV Basis) 87 855 109 164 219 274 13 169 25 22 19 179 238 238 138 208 277 346 a7 n 4 ne 7 20 29 3 25 325 44 31 6 195 28 305 19x262x316 1.9x265x3:56 33x266x439 358x3.11x520 38x322x581 45x3.48x6 3600 5500 5900 ‘8600 450 550 500 675 eos 020 025 1500000, 2000000 72500000 280°/300°C(Optonal) 90 120 150 35 Pressure let ‘As perBS 84S. Part NCV Basis) 92 31 1553 2070 2588 1598 2131 2664 162.0 2253 261.6 1939 2586 3232 55.1 58,1 1102 290 280 360 45. a0 540. 2190 255 335 45x3.4x5.0 48x36x5.7 5.25%3.6x5.85 5400 6600 9300 550 500 675 HONS: arto REGIONAL OFFICES « Now Oth sMurbal« Kola Chonra« Ahmedabad Bangalore «Mydorabad« Pune INTERNATIONAL OFFICES « UK x USA UAE m Germany = Bolgium = Denmark Russa « Sal Arabi « Thaland = Malaysia «Philipines «China Srarl «Por Chile» Bangladesh w Srilanka «Konya Niger Indonesa nen ex cra ergs sae ei ae ag pnts arr ni Alege Neen a tae pada ese ova onary tps rap ner ns mo in ano n s a

You might also like