You are on page 1of 8

This is the Poperty of School of civil E

This Channel are Manageing By SM Hedaetullah And N


Engineering)
Support us And stay connected
This file is only for edicational Perpose. Pls don't misuse it.

Storey Drift Limitation check Sway li


Structure type Ct m No
Concrete moment-resisting frames 0.0466 0.9 BF
Total hight of the building (hx) --> 10 meters F1
Time period (T) --> 0.68 sec F2
Storey Drift from Structure--> 0.26 mm F3
F4
F5
F6
Storey Drift Limitation (Δ) = 0.05 mm F7
F8
F9
H1
Check is Not ok. H2
H3
H4
H5
H6
H7
H8
H9
I1

cd=
actual drift=cd*max drift
from ex or ey from story response plot
and limitation is .020hx where hx is
floor height betwn two floor in meter.
THIS .020hx is from bnbc 6.2.21 or
pdf file page 651.
if actual drift <.020hx then ok
hool of civil Engineering
daetullah And N.J. Disha (B.Sc. In Civil
ering)
stay connected
Perpose. Pls don't misuse it.

Sway limitation or displacement limitation check


Storey Storey Height (m) Dispalacement (mm) Cum.Ht. Limitation of Sway Check
BML 1.82926829268293 1.145 1.8292683 3.65853658536586 OK
GFL 3.04878048780488 7.506 4.8780488 9.75609756097562 OK
Story1 3.04878048780488 13.063 7.9268293 15.8536585365854 OK
Story2 3.04878048780488 18.086 10.97561 21.9512195121951 OK
Story3 3.04878048780488 22.438 14.02439 28.0487804878049 OK
Story4 3.04878048780488 25.126 17.073171 34.1463414634146 OK
Story5 2.4390243902439 18.959 19.512195 39.0243902439024 OK
TR 2.4390243902439 15.871 21.95122 43.9024390243903 OK
#VALUE! #VALUE!
#VALUE! #VALUE!
#VALUE! #VALUE!
#VALUE! #VALUE!
#VALUE! #VALUE!
#VALUE! #VALUE!
#VALUE! #VALUE!
#VALUE! #VALUE!
#VALUE! #VALUE!
#VALUE! #VALUE!
#VALUE! #VALUE!
#VALUE! #VALUE!
Conveter
in ft ft m in mm
72 6 6 1.8292683 0.116125 2.949575
120 10 10 3.0487805 0.495848 12.594539
120 10 10 3.0487805 0.85788 21.790152
120 10 10 3.0487805 1.176256 29.876902
120 10 10 3.0487805 1.42538 36.204652
120 10 10 3.0487805 1.667495 42.354373
96 8 8 2.4390244
96 8 8 2.4390244
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Table 6.2.20: Values for Coefficients to Estimate
Approximate Period
Structure type Ct m
Concrete moment-resisting frames CMRF 0.0466 0.9
Steel moment-resisting frames SMRF 0.0724 0.8
Eccentrically braced steel frame EBSF 0.0731 0.75
All other structural systems AOSS 0.0488 0.75