Powers PRP(1) ESP(2) Prime


■ Model: Voltage (V) KW KVA KW KVA Amps
380/220 56 70 62 77 106.4
PC70X-YT(silent)/FB70X-YT(open) 400/254 56 70 62 77 101.0
220/127 56 70 62 77 183.7

Powered by TIDE POWER


SILENT VERSION

OPEN  VERSION

■ General Specification

Engine Data Alternator Data


Engine brand Tide Power Alternator brand Tide Power
Engine model LR4B3Z-D Alternator model Direct / Single Bearing
Speed control type Electronic Phase / Poles 3-Phase / 4-Pole
Starter motor voltage 24V Power Factor Cos Φ = 0.8
Engine speed (RPM) 1800 AVR Regulation Yes
110% prime power 18.9 Voltage Regulation ± 0.5 %
Fuel
100% prime power 15.7 Insulation Class H
Consumption
(L/H) 75% prime power 12.6 Drip Proof IP23
50% prime power 9.4 Excitation Shunt

Ratings:
All three phase generator sets are rated at 0.8 power factor. All single-phase generator
sets are rated at 0.8 or 1.0 power factor.

(1) PRP (Prime Power):


Available continuously at variable load in lieu of commercially purchased power for an unlimited number of hours per year accordance
with ISO8528-1, and an overload of 10% permitted for one hour in every twelve hours of operation in accordance with ISO 3046-1.

(2) ESP (Standby Power):


Emergency Standby Power in variable load applications in accordance with ISO8528-1 in the event of a utility power failure. No
overload available for this service as relevant alternators are peak continuous rated at 27℃.
       

■ Engine Specification: ■ Standard Configuration

Basic technical data Accesories


No. of cylinders 4 Radiator
Cylinder arrangement In-line Oil sensor
Cycle 4 stroke Water temperature sensor
Injection system Direct Oil drainage pump
Aspiration type Turbocharger air filter, oil filter, fuel filter
Compression ratio 17:1 Rubber anti-vibration mount
Bore 108mm Ground Protection
Stroke 125mm AVR
Displacement 4.58L Battery charger
Governor type Mechanical Maintenance free battery
Oil capacity 14L Breaker
Coolant capacity-engine 6L Control panel IP42

■ Dimensions ■ Control Panel Function Summary

Dimension and Weight Generator Protection and Functions


Dimension Open Silent Abnormal voltage
Length (L) 1800mm 2600mm Over current Protection
Width (W) 760mm 980mm Over Frecuency Protection
Height (H) 1250mm 1300mm Short Circuit Protection
Net Weight 850Kg 1300Kg Low Oil Pressure Protection
Fuel Tank (h) - 8 High Temperature Protection
Noise(dB) at 7m N/A <85 Alternator Charger
Remote Start
AMF (Auto Main Failure)
Fault History
Oil Pressure Visualization
Water Temperature Visualization
Fuel Meter
Speed
Battery Voltage
Runing Hours

Standard reference Conditions:


Note: Standard reference condition 25°C[77°F] air inlet temp,
1000m(328ft) A.S.L 30% relative humidity. Fuel consumption data with
diesel fuel with specific gravity of 0.85 and conforming to BS 2869: 1998,
Class A2.