Powers PRP(1) ESP(2) Prime

■ Model: Voltage (V) KW KVA KW KVA Amps


380/220 44 55 48 61 83.6
FC55X-YT(silent)/FB55X-YT(open) 400/254 44 55 48 61 79.4
220/127 44 55 48 61 144.3

Powered by TIDE POWER


SILENT VERSION

OPEN  VERSION

■ General Specification

Engine Data Alternator Data


Engine brand Tide Power Alternator brand Tide Power
Engine model LR4B5-D Coupling/N° of bearings Direct / Single Bearing
Speed control type Mechanical Phase / Poles 3-Phase / 4-Pole
Starter motor voltage 12V Power Factor Cos Φ = 0.8
Engine speed (RPM) 1800 AVR Regulation Yes
standby power 14.43 Voltage Regulation ± 0.5 %
Fuel
100% prime power 13.12 Insulation Class H
Consumption
(L/H) 75% prime power 11.15 Drip Proof IP23
50% prime power 9.84 Excitation Shunt

Ratings:
All three phase generator sets are rated at 0.8 power factor. All single-phase generator
sets are rated at 0.8 or 1.0 power factor.

(1) PRP (Prime Power):


Available continuously at variable load in lieu of commercially purchased power for an unlimited number of hours per year accordance
with ISO8528-1, and an overload of 10% permitted for one hour in every twelve hours of operation in accordance with ISO 3046-1.

(2) ESP (Standby Power):


Emergency Standby Power in variable load applications in accordance with ISO8528-1 in the event of a utility power failure. No
overload available for this service as relevant alternators are peak continuous rated at 27℃.
■ Engine Specification: ■ Standard Configuration

Basic technical data Accesories


No. of cylinders 4 Radiator
Cylinder arrangement In-line Oil sensor
Cycle 4 stroke Water temperature sensor
Injection system Direct Oil drainage pump
Aspiration type Naturally Aspirated air filter, oil filter, fuel filter
Compression ratio 17:1 Rubber anti-vibration mount
Bore 108mm Ground Protection
Stroke 135mm AVR
Displacement 5.18L Battery charger
Governor type Mechanical Maintenance free battery
Oil capacity 14L Breaker
Coolant capacity-engine 6L Control panel IP42

■ Dimensions ■ Control Panel Function Summary

Dimension and Weight Generator Protection and Functions


Dimension Open Silent Abnormal voltage
Length (L) - 2724mm Over current Protection
Width (W) - 1150mm Over Frecuency Protection
Height (H) - 1420mm Short Circuit Protection
Net Weight - 1345Kg Low Oil Pressure Protection
Fuel Tank (L) - 310 High Temperature Protection
Noise(dB) at 7m N/A - Alternator Charger
Remote Start
AMF (Auto Main Failure)
Fault History
Oil Pressure Visualization
Water Temperature Visualization
Fuel Meter
Speed
Battery Voltage
Runing Hours

Standard reference Conditions:


Note: Standard reference condition 25°C[77°F] air inlet temp,
1000m(328ft) A.S.L 30% relative humidity. Fuel consumption data with
diesel fuel with specific gravity of 0.85 and conforming to BS 2869: 1998,
Class A2.