You are on page 1of 3

Mecca Perkins Series

MC70P Technical Data

Features
♦ Perkins engine 1104A-44TG1
♦ Leorysomer alternator TAL-A44-C
♦ Deepsea Controller DSE6020
♦ MCCB Breaker
♦ Base fuel tank
♦ Emergency stop button,alarm,panel light
♦ 12/24V maintainance free battery, battery wires
♦ Float battery charger
♦ Battery isolator switch
♦ Powder coated canopy
♦ Radiator with engine driven fan mounted
♦ Anti-vibration mountings
♦ Silencers with flexible connects and elbow
♦ Test report, drawing, operation and maintainance manual

Genset Main Data

Genset Model MC70P


Prime Power 52KW / 65KVA
Standby Power 56KW / 70KVA
Frequency/Speed 50Hz/1500rpm
Standard Voltage 380/220V
Power Factor 0.8
Phases Three phases, four wires
110% prime power 16.5
100% prime power 14.8
Fuel Cons. (L/H)
75% prime power 11.2
50% prime power 8
Open Silent
Dimensions(L×W×H)mm
1800x730x1250 2420X960X1350
Weight (kg) 960 1650
Base Fuel Tank (L) 130 150
Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO8528-1. A 10% overload
capability is available for a period of 1 hour within 12-hour period of operation. In accordance with ISO 3046-1.

Standby Power Rating is applicable for supplying emergency power in variable load applications for up to 200 hours per year in accordance with ISO8528-1.
Overload is not allowed.
Engine Data

Engine Model 1104A-44TG1


Brand Perkins
Engine Speed 1500rpm
Gross Prime Power(Kw) 59.6
Bore and Stroke 105*127
Cy/No. and Arrangement Water-cooled, 4-stroke,4-Cyllinders Vertical in-line
Displacement(L) 4.4
Compression Ratio 17.25:1
Lub oil Capacity (L)(Total system) 8
Coolant Capacity (L)(With radiator) 13
Aspiration Turbocharged
Governor Type Mechanical
Starter (V) 12

Alternator Data

Alternator Model TAL-A44-C


Brand Leorysomer
Output Power(Kva) 81
Voltage Control AVR
Number of Phase 3
Power Factor (Cos Phi) 0.8
Insulation Class H
Protection 23
Altitude ≤ 1000 m
Number of Pole 4
Bearing Single
Connection Series Star
Coupling Direct
Control System

Deepsea Panel Model

DSE6020

Deepsea 6020 is an auto mains failure controller for single Features:


generator, it can monitor and protect the generator working ♦ Protection: Automatic start/stop,
all the time. it has a LCD display which clearly shows the load transfer and alarming of
status of the engine. this controller include seven inputs and generator;
six outputs. This controller can also be programmed using ♦ CAN and magnetic pick-up versions.
the frong panel or by using DSE configuration Suite PC ♦ PC and front panel configurable
software. ♦ 4 digital inputs and 3 analogue inputs.
Parameters: ♦ 6 outputs(4 configurable on magnetic pick-up, 6
This controller can provide Generator frequency, Under/over configurable on Canbus version).
speed, Generator volts, Generator current, Engine oil ♦ 3 phase generator and mains voltage monitoring.
pressure, Engine coolant temperature, Flexible fuel level, ♦ remote start on or off load.
Hours run counter, Battery volts, Fail to start/stop, ♦ advanced metering capability.
Emergency Stop. Failed to reach loading voltage/frequency, ♦ test button.
Charge fail, Loss of magnetic pick-up signal, Low DC voltage, ♦ protected solid state outputs.
CAN diagnostics and CAN fail/error, Mains volts 3 phase, ♦ transfer between mains and generator power.
Mains frequency, AMF indications ♦ user-friendly set-up and button layout.
Protection: ♦ multiple engine parameters are monitored simultaneously.
♦ Low Oil Pressure ♦ module can be configured to suit individual applications.
♦ High water Temperature ♦ IP 65 rating offers advanced resistance to water ingress
♦ High voltage and low voltage when gasket is fitted. .
♦ Overspeed
♦ Volt adjuster and frequency adjuster.

Optional
Genset Fuel System Alternator
* Trailer * Dual wall base fuel tank * PMG
* Dual frequency (50/60hz both) * Enlarge base fuel tank * Drop kits
* Custormised canopy design * External daily fuel tank * Anti-condensation heater
* Special required sound level * External Fuel Pump * Winding temperature measuring instrument
* 50℃ ambient temperature * Low fuel level alarm * Single phase
* Synchronization system * Automatic fuel feeding system * Double bearing
* Fuel three-valves * Anti-damp and anti-corrosion treatment
Exhaust System Controller Engine
* Custormised exhaust connection way * Remote control system * Water jacket preheater
* Synchronization controller * Lub oil heater
* ATS * Electronic governor