You are on page 1of 6

Maximum design axial load= 1292.

265 KN

Design bending moment=109.095 KNm

Concrete mix= M20

Characteristic strength of reinforcement = 500 N/mm2


Size of column= 500 mm × 500 mm

Safe bearing capacity of soil=120 KN/m2(Assumed)


Increasing 25% we take S.B.C as 150 KN/m2
So, Given column axial load= 1292.265 KN

Add 10% for self-weight= 129.2 KN

Total= 1421.465 KN
Check for Bending Moment:
Check for One-way shear
Check for two-way shear
Check for Bearing Stress
Check for Development Length