This document contains calibration sheets for 3 pressure transmitters at the Ceyhan Botas Terminal in Turkey. It summarizes the instrument tag numbers, calibration ranges, test equipment used, and results of calibration tests at 0%, 25%, 50%, 75%, and 100% of the calibration range. All transmitters showed errors within the allowable tolerance of ±0.25% and passed calibration.
This document contains calibration sheets for 3 pressure transmitters at the Ceyhan Botas Terminal in Turkey. It summarizes the instrument tag numbers, calibration ranges, test equipment used, and results of calibration tests at 0%, 25%, 50%, 75%, and 100% of the calibration range. All transmitters showed errors within the allowable tolerance of ±0.25% and passed calibration.
This document contains calibration sheets for 3 pressure transmitters at the Ceyhan Botas Terminal in Turkey. It summarizes the instrument tag numbers, calibration ranges, test equipment used, and results of calibration tests at 0%, 25%, 50%, 75%, and 100% of the calibration range. All transmitters showed errors within the allowable tolerance of ±0.25% and passed calibration.
SITE NAME Ceyhan Botas Terminal, Turkey INSTRUMENT PRESSURE TRANSMITTER
LOCATION Ceyhan, Turkey INSTRUMENT TAG NO. 80/PT-1 STREAM TAG NO. STREAM - 1 SERIAL NO. Not Readable SKID TAG NO. BERTH #1 & #2 METERING SYSTEM MAKE Rosemount CALIBRATED BY MEHMET DEMİR MODEL 3051TG3A2B21AE8D4M5Q4 CALIBRATED RANGE 0 to 6,88 Bar TOLERANCE ± 0.25%
TEST EQUIPMENT DATA
MODEL No. CALIBRATION CALIBRATION TYPE MANUFACTURER SERIAL No. CERTIFICATE DATE CERTIFICATE No. Multifunction Calibrator Beamex MC6-Ex 701658 19-NOV-2021 K026-19P1799 AS FOUND AS LEFT AS FOUND / AS LEFT 0
SIMULATED PRESSURE EXPECTED RESULTS RECORDED READING ERROR % SPAN RESULTS
Ref. Test Sheet Rev No. DATE #001 WI CAL 26 1 21 FEB 2022 PIT CEYHAN BOTAS TERMINAL
INSTRUMENT CALIBRATION SHEET
SITE NAME Ceyhan Botas Terminal, Turkey INSTRUMENT PRESSURE TRANSMITTER
LOCATION Ceyhan, Turkey INSTRUMENT TAG NO. 80/PT-2 STREAM TAG NO. STREAM - 2 SERIAL NO. Not Readable SKID TAG NO. BERTH #1 & #2 METERING SYSTEM MAKE Rosemount CALIBRATED BY MEHMET DEMİR MODEL 3051TG3A2B21AE8D4M5Q4 CALIBRATED RANGE 0 to 6,88 Bar TOLERANCE ± 0.25%
TEST EQUIPMENT DATA
MODEL No. CALIBRATION CALIBRATION TYPE MANUFACTURER SERIAL No. CERTIFICATE DATE CERTIFICATE No. Multifunction Calibrator Beamex MC6-Ex 701658 19-NOV-2021 K026-19P1799 0 AS FOUND AS LEFT AS FOUND / AS LEFT
SIMULATED PRESSURE EXPECTED RESULTS RECORDED READING ERROR % SPAN RESULTS
Ref. Test Sheet Rev No. DATE #009 WI CAL 26 1 21 FEB 2022 PIT CEYHAN BOTAS TERMINAL
INSTRUMENT CALIBRATION SHEET
SITE NAME Ceyhan Botas Terminal, Turkey INSTRUMENT PRESSURE TRANSMITTER
LOCATION Ceyhan, Turkey INSTRUMENT TAG NO. 80/PT-3 STREAM TAG NO. STREAM - 3 SERIAL NO. Not Readable SKID TAG NO. BERTH #1 & #2 METERING SYSTEM MAKE Rosemount CALIBRATED BY MEHMET DEMİR MODEL 3051TG3A2B21AE8D4M5Q4 CALIBRATED RANGE 0 to 6,88 Bar TOLERANCE ± 0.25%
TEST EQUIPMENT DATA
MODEL No. CALIBRATION CALIBRATION TYPE MANUFACTURER SERIAL No. CERTIFICATE DATE CERTIFICATE No. Multifunction Calibrator Beamex MC6-Ex 701658 19-NOV-2021 K026-19P1799 0 AS FOUND AS LEFT AS FOUND / AS LEFT
SIMULATED PRESSURE EXPECTED RESULTS RECORDED READING ERROR % SPAN RESULTS
Ref. Test Sheet Rev No. DATE #017 WI CAL 26 1 21 FEB 2022 PIT CEYHAN BOTAS TERMINAL
INSTRUMENT CALIBRATION SHEET
SITE NAME Ceyhan Botas Terminal, Turkey INSTRUMENT PRESSURE TRANSMITTER
LOCATION Ceyhan, Turkey INSTRUMENT TAG NO. 80/PT-4 STREAM TAG NO. STREAM - 4 SERIAL NO. Not Readable SKID TAG NO. BERTH #1 & #2 METERING SYSTEM MAKE Rosemount CALIBRATED BY MEHMET DEMİR MODEL 3051TG3A2B21AE8D4M5Q4 CALIBRATED RANGE 0 to 6,88 Bar TOLERANCE ± 0.25%
TEST EQUIPMENT DATA
MODEL No. CALIBRATION CALIBRATION TYPE MANUFACTURER SERIAL No. CERTIFICATE DATE CERTIFICATE No. Multifunction Calibrator Beamex MC6-Ex 701658 19-NOV-2021 K026-19P1799 0 AS FOUND AS LEFT AS FOUND / AS LEFT
SIMULATED PRESSURE EXPECTED RESULTS RECORDED READING ERROR % SPAN RESULTS
Ref. Test Sheet Rev No. DATE #025 WI CAL 26 1 21 FEB 2022 PIT CEYHAN BOTAS TERMINAL
INSTRUMENT CALIBRATION SHEET
SITE NAME Ceyhan Botas Terminal, Turkey INSTRUMENT PRESSURE TRANSMITTER
LOCATION Ceyhan, Turkey INSTRUMENT TAG NO. 80/PT-5 STREAM TAG NO. STREAM - 5 SERIAL NO. Not Readable SKID TAG NO. BERTH #1 & #2 METERING SYSTEM MAKE Rosemount CALIBRATED BY MEHMET DEMİR MODEL 3051TG3A2B21AE8D4M5Q4 CALIBRATED RANGE 0 to 6,88 Bar TOLERANCE ± 0.25%
TEST EQUIPMENT DATA
MODEL No. CALIBRATION CALIBRATION TYPE MANUFACTURER SERIAL No. CERTIFICATE DATE CERTIFICATE No. Multifunction Calibrator Beamex MC6-Ex 701658 19-NOV-2021 K026-19P1799 0 AS FOUND AS LEFT AS FOUND / AS LEFT
SIMULATED PRESSURE EXPECTED RESULTS RECORDED READING ERROR % SPAN RESULTS
Ref. Test Sheet Rev No. DATE #033 WI CAL 26 1 21 FEB 2022 PIT CEYHAN BOTAS TERMINAL
INSTRUMENT CALIBRATION SHEET
SITE NAME Ceyhan Botas Terminal, Turkey INSTRUMENT PRESSURE TRANSMITTER
LOCATION Ceyhan, Turkey INSTRUMENT TAG NO. 80/PT-6 STREAM TAG NO. STREAM - 6 SERIAL NO. Not Readable SKID TAG NO. BERTH #1 & #2 METERING SYSTEM MAKE Rosemount CALIBRATED BY MEHMET DEMİR MODEL 3051TG3A2B21AE8D4M5Q4 CALIBRATED RANGE 0 to 6,88 Bar TOLERANCE ± 0.25%
TEST EQUIPMENT DATA
MODEL No. CALIBRATION CALIBRATION TYPE MANUFACTURER SERIAL No. CERTIFICATE DATE CERTIFICATE No. Multifunction Calibrator Beamex MC6-Ex 701658 19-NOV-2021 K026-19P1799 0 AS FOUND AS LEFT AS FOUND / AS LEFT Metni buray SIMULATED PRESSURE EXPECTED RESULTS RECORDED READING ERROR % SPAN RESULTS EXPECTED EXPECTED (Flow Computer Readings) SPAN PRESSURE RISING FALLING RISING FALLING PRESSURE VALUE CURRENT RISING FALLING (%) Bar Bar (mA) (mA) (mA) (%) 0% 0,00 0,00 4,0000 4,006 4,005 0,038% 0,031% PASS PASS 25% 1,72 1,72 8,0000 8,000 8,002 0,000% 0,013% PASS PASS 50% 3,44 3,44 12,0000 12,004 12,000 0,025% 0,000% PASS PASS 75% 5,16 5,16 16,0000 16,001 16,000 0,006% 0,000% PASS PASS 100% 6,88 6,88 20,0000 20,010 20,000 0,063% 0,000% PASS PASS ALLOWABLE TOLERANCE ± 0.25 % MAXIMUM % ERROR 0,063% PASS REMARKS: The results are within allowable tolerance. Calibrated By: MEHMET DEMİR
Test Ref. Reference Drawing Number:
Ref. Test Sheet Rev No. DATE #041 WI CAL 26 1 21 FEB 2022 PIT CEYHAN BOTAS TERMINAL
INSTRUMENT CALIBRATION SHEET
SITE NAME Ceyhan Botas Terminal, Turkey INSTRUMENT PRESSURE TRANSMITTER
LOCATION Ceyhan, Turkey INSTRUMENT TAG NO. 80/PT-7 STREAM TAG NO. STREAM - 7 SERIAL NO. Not Readable SKID TAG NO. BERTH #1 & #2 METERING SYSTEM MAKE Rosemount CALIBRATED BY MEHMET DEMİR MODEL 3051TG3A2B21AE8D4M5Q4 CALIBRATED RANGE 0 to 6,88 Bar TOLERANCE ± 0.25%
TEST EQUIPMENT DATA
MODEL No. CALIBRATION CALIBRATION TYPE MANUFACTURER SERIAL No. CERTIFICATE DATE CERTIFICATE No. Multifunction Calibrator Beamex MC6-Ex 701658 19-NOV-2021 K026-19P1799 0 AS FOUND AS LEFT AS FOUND / AS LEFT
SIMULATED PRESSURE EXPECTED RESULTS RECORDED READING ERROR % SPAN RESULTS
Ref. Test Sheet Rev No. DATE #049 WI CAL 26 1 21 FEB 2022 PIT CEYHAN BOTAS TERMINAL
INSTRUMENT CALIBRATION SHEET
SITE NAME Ceyhan Botas Terminal, Turkey INSTRUMENT PRESSURE TRANSMITTER
LOCATION Ceyhan, Turkey INSTRUMENT TAG NO. 80/PT-8 STREAM TAG NO. STREAM - 8 SERIAL NO. Not Readable SKID TAG NO. BERTH #1 & #2 METERING SYSTEM MAKE Rosemount CALIBRATED BY MEHMET DEMİR MODEL 3051TG3A2B21AE8D4M5Q4 CALIBRATED RANGE 0 to 6,88 Bar TOLERANCE ± 0.25%
TEST EQUIPMENT DATA
MODEL No. CALIBRATION CALIBRATION TYPE MANUFACTURER SERIAL No. CERTIFICATE DATE CERTIFICATE No. Multifunction Calibrator Beamex MC6-Ex 701658 19-NOV-2021 K026-19P1799 0 AS FOUND AS LEFT AS FOUND / AS LEFT
SIMULATED PRESSURE EXPECTED RESULTS RECORDED READING ERROR % SPAN RESULTS
Ref. Test Sheet Rev No. DATE #057 WI CAL 26 1 21 FEB 2022 PIT CEYHAN BOTAS TERMINAL
INSTRUMENT CALIBRATION SHEET
SITE NAME Ceyhan Botas Terminal, Turkey INSTRUMENT PRESSURE TRANSMITTER
LOCATION Ceyhan, Turkey INSTRUMENT TAG NO. 80/PT-9 STREAM TAG NO. STREAM - 9 SERIAL NO. Not Readable SKID TAG NO. BERTH #1 & #2 METERING SYSTEM MAKE Rosemount CALIBRATED BY MEHMET DEMİR MODEL 3051TG3A2B21AE8D4M5Q4 CALIBRATED RANGE 0 to 6,88 Bar TOLERANCE ± 0.25%
TEST EQUIPMENT DATA
MODEL No. CALIBRATION CALIBRATION TYPE MANUFACTURER SERIAL No. CERTIFICATE DATE CERTIFICATE No. Multifunction Calibrator Beamex MC6-Ex 701658 19-NOV-2021 K026-19P1799 0 AS FOUND AS LEFT AS FOUND / AS LEFT
SIMULATED PRESSURE EXPECTED RESULTS RECORDED READING ERROR % SPAN RESULTS
EXPECTED EXPECTED (Flow Computer Readings) Metni bura SPAN PRESSURE RISING FALLING RISING FALLING PRESSURE VALUE CURRENT RISING FALLING (%) Bar Bar (mA) (mA) (mA) (%) 0% 0,00 0,00 4,0000 4,001 4,001 0,006% 0,006% PASS PASS 25% 1,72 1,72 8,0000 8,002 7,998 0,013% -0,012% PASS PASS 50% 3,44 3,44 12,0000 12,001 11,998 0,006% -0,013% PASS PASS 75% 5,16 5,16 16,0000 16,000 15,997 0,000% -0,019% PASS PASS 100% 6,88 6,88 20,0000 20,001 19,998 0,006% -0,012% PASS PASS ALLOWABLE TOLERANCE ± 0.25 % MAXIMUM % ERROR 0,013% PASS REMARKS: The results are within allowable tolerance. Calibrated By: MEHMET DEMİR
Test Ref. Reference Drawing Number:
Ref. Test Sheet Rev No. DATE #065 WI CAL 26 1 21 FEB 2022 PIT CEYHAN BOTAS TERMINAL
INSTRUMENT CALIBRATION SHEET
SITE NAME Ceyhan Botas Terminal, Turkey INSTRUMENT PRESSURE TRANSMITTER
LOCATION Ceyhan, Turkey INSTRUMENT TAG NO. Prover Inlet Pressure Transmitter STREAM TAG NO. Bi-Directional Prover SERIAL NO. Not Readable SKID TAG NO. BERTH #1 & #2 METERING SYSTEM MAKE Rosemount CALIBRATED BY MEHMET DEMİR MODEL 3051TG3A2B21AE8D4M5Q4 CALIBRATED RANGE 0 to 6,88 Bar TOLERANCE ± 0.25%
TEST EQUIPMENT DATA
MODEL No. CALIBRATION CALIBRATION TYPE MANUFACTURER SERIAL No. CERTIFICATE DATE CERTIFICATE No. Multifunction Calibrator Beamex MC6-Ex 701658 19-NOV-2021 K026-19P1799 0 AS FOUND AS LEFT AS FOUND / AS LEFT
SIMULATED PRESSURE EXPECTED RESULTS RECORDED READING ERROR % SPAN RESULTS
Ref. Test Sheet Rev No. DATE #073 WI CAL 26 1 21 FEB 2022 PIT CEYHAN BOTAS TERMINAL
INSTRUMENT CALIBRATION SHEET
SITE NAME Ceyhan Botas Terminal, Turkey INSTRUMENT PRESSURE TRANSMITTER
LOCATION Ceyhan, Turkey INSTRUMENT TAG NO. Prover Outlet Pressure Transmitter STREAM TAG NO. Bi-Directional Prover SERIAL NO. Not Readable SKID TAG NO. BERTH #1 & #2 METERING SYSTEM MAKE Rosemount CALIBRATED BY MEHMET DEMİR MODEL 3051TG3A2B21AE8D4M5Q4 CALIBRATED RANGE 0 to 6,88 Bar TOLERANCE ± 0.25%
TEST EQUIPMENT DATA
MODEL No. CALIBRATION CALIBRATION TYPE MANUFACTURER SERIAL No. CERTIFICATE DATE CERTIFICATE No. Multifunction Calibrator Beamex MC6-Ex 701658 19-NOV-2021 K026-19P1799 0 AS FOUND AS LEFT AS FOUND / AS LEFT
SIMULATED PRESSURE EXPECTED RESULTS RECORDED READING ERROR % SPAN RESULTS
Ref. Test Sheet Rev No. DATE #075 WI CAL 26 1 21 FEB 2022 PIT CEYHAN BOTAS TERMINAL
INSTRUMENT CALIBRATION SHEET
SITE NAME Ceyhan Botas Terminal, Turkey INSTRUMENT PRESSURE TRANSMITTER
LOCATION Ceyhan, Turkey INSTRUMENT TAG NO. Berth #1 Inlet Pressure Transmitter STREAM TAG NO. BERTH #1 METERING SYSTEM SERIAL NO. Not Readable SKID TAG NO. BERTH #1 METERING SYSTEM MAKE Rosemount CALIBRATED BY MEHMET DEMİR MODEL 3051TG3A2B21AE8D4M5Q4 CALIBRATED RANGE 0 to 6,88 Bar TOLERANCE ± 0.25%
TEST EQUIPMENT DATA
MODEL No. CALIBRATION CALIBRATION TYPE MANUFACTURER SERIAL No. CERTIFICATE DATE CERTIFICATE No. Multifunction Calibrator Beamex MC6-Ex 701658 19-NOV-2021 K026-19P1799 0 AS FOUND AS LEFT AS FOUND / AS LEFT
SIMULATED PRESSURE EXPECTED RESULTS RECORDED READING ERROR % SPAN RESULTS
Ref. Test Sheet Rev No. DATE #077 WI CAL 26 1 21 FEB 2022 PIT CEYHAN BOTAS TERMINAL
INSTRUMENT CALIBRATION SHEET
SITE NAME Ceyhan Botas Terminal, Turkey INSTRUMENT PRESSURE TRANSMITTER
LOCATION Ceyhan, Turkey INSTRUMENT TAG NO. Berth #2 Inlet Pressure Transmitter STREAM TAG NO. BERTH #2 METERING SYSTEM SERIAL NO. Not Readable SKID TAG NO. BERTH #2 METERING SYSTEM MAKE Rosemount CALIBRATED BY MEHMET DEMİR MODEL 3051TG3A2B21AE8D4M5Q4 CALIBRATED RANGE 0 to 6,88 Bar TOLERANCE ± 0.25%
TEST EQUIPMENT DATA
MODEL No. CALIBRATION CALIBRATION TYPE MANUFACTURER SERIAL No. CERTIFICATE DATE CERTIFICATE No. Multifunction Calibrator Beamex MC6-Ex 701658 19-NOV-2021 K026-19P1799 0 AS FOUND AS LEFT AS FOUND / AS LEFT
SIMULATED PRESSURE EXPECTED RESULTS RECORDED READING ERROR % SPAN RESULTS
Ref. Test Sheet Rev No. DATE #079 WI CAL 26 1 21 FEB 2022 PIT CEYHAN BOTAS TERMINAL
INSTRUMENT CALIBRATION SHEET
SITE NAME Ceyhan Botas Terminal, Turkey INSTRUMENT PRESSURE TRANSMITTER
LOCATION Ceyhan, Turkey INSTRUMENT TAG NO. Berth #1 DT Pressure Transmitter STREAM TAG NO. Quality System SERIAL NO. Not Readable SKID TAG NO. BERTH #1 METERING SYSTEM MAKE Rosemount CALIBRATED BY MEHMET DEMİR MODEL 3051TG3A2B21AE8D4M5Q4 CALIBRATED RANGE 0 to 6,88 Bar TOLERANCE ± 0.25%
TEST EQUIPMENT DATA
MODEL No. CALIBRATION CALIBRATION TYPE MANUFACTURER SERIAL No. CERTIFICATE DATE CERTIFICATE No. Multifunction Calibrator Beamex MC6-Ex 701658 19-NOV-2021 K026-19P1799 0 AS FOUND AS LEFT AS FOUND / AS LEFT
SIMULATED PRESSURE EXPECTED RESULTS RECORDED READING ERROR % SPAN RESULTS
Ref. Test Sheet Rev No. DATE #081 WI CAL 26 1 21 FEB 2022 PIT CEYHAN BOTAS TERMINAL
INSTRUMENT CALIBRATION SHEET
SITE NAME Ceyhan Botas Terminal, Turkey INSTRUMENT PRESSURE TRANSMITTER
LOCATION Ceyhan, Turkey INSTRUMENT TAG NO. Berth #2 DT Pressure Transmitter STREAM TAG NO. Quality System SERIAL NO. Not Readable SKID TAG NO. BERTH #2 METERING SYSTEM MAKE Rosemount CALIBRATED BY MEHMET DEMİR MODEL 3051TG3A2B21AE8D4M5Q4 CALIBRATED RANGE 0 to 6,88 Bar TOLERANCE ± 0.25%
TEST EQUIPMENT DATA
MODEL No. CALIBRATION CALIBRATION TYPE MANUFACTURER SERIAL No. CERTIFICATE DATE CERTIFICATE No. Multifunction Calibrator Beamex MC6-Ex 701658 19-NOV-2021 K026-19P1799 0 AS FOUND AS LEFT AS FOUND / AS LEFT
SIMULATED PRESSURE EXPECTED RESULTS RECORDED READING ERROR % SPAN RESULTS
EXPECTED EXPECTED (Flow Computer Readings) Metni buraya SPAN PRESSURE RISING FALLING RISING FALLING PRESSURE VALUE CURRENT RISING FALLING (%) Bar Bar (mA) (mA) (mA) (%) 0% 0,00 0,00 4,0000 4,000 3,998 0,000% -0,012% PASS PASS 25% 1,72 1,72 8,0000 7,995 7,992 -0,031% -0,050% PASS PASS 50% 3,44 3,44 12,0000 12,000 11,990 0,000% -0,062% PASS PASS 75% 5,16 5,16 16,0000 16,000 15,996 0,000% -0,025% PASS PASS 100% 6,88 6,88 20,0000 20,001 19,999 0,006% -0,006% PASS PASS ALLOWABLE TOLERANCE ± 0.25 % MAXIMUM % ERROR 0,006% PASS REMARKS: The results are within allowable tolerance. Calibrated By: MEHMET DEMİR
Test Ref. Reference Drawing Number:
Ref. Test Sheet Rev No. DATE #083 WI CAL 26 1 21 FEB 2022