You are on page 1of 11

Intelligent Hydropower Technology

共创价值 | 共享成功 第 01 页
| Intelligent Hydropower >>> Function introduction

Running Adjustment and optimization (maintenance and recovery)


Optimization
Operation and maintenance (auxiliary decision-making)

Fault diagnosis (reasoning and confirmation)

Intelligent Condition assessment (data analysis)


Diagnosis
State awareness (data acquisition )
Intelligent
Monitoring

Co-create Value | Share Success Page 01


| Intelligent Hydropower >>>Intelligent Monitoring>>> Production information monitoring
Use real and complete real-time and historical data to realize index management, supervise, benchmark, analyze
and make business decisions on the indexes of each subsidiary. Upload the unit parameters of each subsidiary to the
central monitoring room of the group to realize the functions of group overview, production overview, real-time
monitoring, historical curve query, historical playback, working condition analysis, equipment status monitoring,
index parameter statistics and so on.

Co-create Value | Share Success Page 02


| Intelligent Hydropower >>>Intelligent Monitoring >>> Trash rack blockage monitoring
With high-definition visual analysis camera and built-in image recognition intelligent big data algorithm, it
automatically analyzes and uploads the water and underwater monitoring images of the trash gate in real time to judge
the pollution accumulation degree of the gate and the blockage of the trash gate. When the pollution accumulation
degree and blockage condition reach a certain degree, the system automatically sends out pollution removal and
blockage removal alarm information to effectively guide the pollution removal and anti blockage work.

Co-create Value | Share Success Page 03


| Intelligent Hydropower >>>Intelligent Diagnosis >>>

Dynamic characteristic monitoring and diagnosis of generator stator and rotor structure

By monitoring the change of air gap between stator and


rotor of hydro generator, the dynamic characteristics of
generator rotor and stator structure are monitored.
The equivalent values of generator stator out of
roundness, rotor out of roundness, maximum air gap,
minimum air gap and rotor eccentricity under various
working conditions are given, and the relevant curves can be
drawn to analyze stator creep, magnetic tension imbalance,
rotor magnetic pole looseness and other faults.

Co-create Value | Share Success Page 04


| Intelligent Hydropower >>>Intelligent Diagnosis >>> Generator partial discharge diagnosis
By monitoring the partial discharge, discharge times and discharge phase of each phase of generator stator
winding, find the insulation state and change trend of generator stator winding, analyze the causes of generator
insulation deterioration and judge the location of fault. The system can predict the fault risk in advance, so as to
provide technical basis for condition based maintenance of generator.

Co-create Value | Share Success Page 05


| Intelligent Hydropower >>>Intelligent Diagnosis >>>

Vibration monitoring and diagnosis of generator stator bar

The looseness of the slot wedge will cause the aging of the insulation material of the generator
stator coil, and the insulation system will be exposed to the harsh operating environment. Once the
slot wedge can no longer hold the wire rod, vibration will occur, which will greatly weaken the
insulation performance, lead to various faults, such as discharge and short circuit, and the unit
shutdown event will rise sharply. The intelligent diagnosis system can collect the wire rod vibration,
analyze the frequency spectrum and trend, and give an alarm in time in case of abnormality,
which can avoid the insulation damage and abnormal shutdown of the unit caused by excessive wire
rod vibration.

Co-create Value | Share Success Page 06


| Intelligent Hydropower >>>Intelligent Diagnosis >>> Diagnosis of rotor interturn short circuit

According to the characteristics of interturn short circuit fault of generator rotor, combined with the monitoring
data of rotor excitation current early warning, rotor vibration early warning and rotor turn detection device, the
rotor interturn short circuit fault is comprehensively diagnosed online from the three dimensions of generator rotor
electrical, mechanical and magnetic field, the fault location is carried out, and the short circuit slot number is given to
meet the needs of rotor interturn short circuit diagnosis of power plant. Effectively improve the operation reliability of
the unit.

Co-create Value | Share Success Page 07


| Intelligent Hydropower >>>Running Optimization>>> Unit stability analysis
Monitor the stability parameters such as frame vibration, large shaft swing, pressure pulsation and lifting
capacity during the stable operation and transition of the unit, conduct real-time, parallel and whole cycle
sampling and corresponding calculation and processing, and dynamically display the monitored data and status in
the form of structural diagram, bar diagram, data table, curve, etc. Through the stability data under various working
conditions automatically accumulated by the monitoring system, the unstable operation working condition areas
such as vortex zone working condition area, special vibration and pressure pulsation area of the unit can be
divided, so as to optimize and guide the safe and stable operation of the unit

Co-create Value | Share Success Page 08


| Intelligent Hydropower >>>Running Optimization >>>
Operation analysis of unit in unstable working condition area
By automatically collecting and analyzing the vibration, swing and pressure pulsation data in each load
changing process, the unstable operating condition area and the corresponding vibration data characteristics
are automatically obtained. Analyze the characteristic parameters such as unit output limit, operation efficiency
zone and stability zone, so as to provide basic data for safe, stable and efficient operation of the unit. Through the
massive working condition data accumulated by the system for a long time, the stability data of the full head of the
unit can be obtained, which provides a basis for analyzing and mastering the optimal operating condition area and
unstable operating condition area of the unit, optimizing operation and formulating alarm limits.

Co-create Value | Share Success Page 09


| Intelligent Hydropower >>>Running Optimization >>>
Transient characteristics evaluation of generating units
Automatically identify the transient, steady-state and other working conditions of the unit, automatically
accumulate the steady-state operation performance data of the unit under different loads / heads, and
automatically form various performance curves through the performance analysis tool, so as to provide a
convenient means to master the characteristics of the unit.