You are on page 1of 1

Printed on: 02/21/2022

Coupling Pipe Body

TenarisHydril Blue® Grade: P110


Body: White
Grade: P110
1st Band: White
1st Band: - 2nd Band: -
2nd Band: - 3rd Band: -
3rd Band: - 4th Band: -
5th Band: -
6th Band: -

Outside Diameter 219.08 mm Wall Thickness 12.70 mm Grade P110

Min. Wall Thickness 87.50 % Pipe Body Drift API Standard Type Casing

Connection OD Option REGUL AR

Pipe Body Data

Geometry Performance

Nominal OD 219.08 mm Wall Thickness 12.70 mm Body Yield Strength 6.25 x1000 kN

Nominal Weight 65.48 kg/m Plain End Weight 64.63 kg/m Min. Internal Yield Pressure 76,900 kPa

Drift 190.50 mm OD Tolerance API SMYS 758,400 kPa

Nominal ID 193.68 mm Collapse Pressure 58,100 kPa

Connection Data

Geometry Performance Make-Up Torques

Connection OD 241 mm Tension Efficiency 100 % Minimum 24,100 N • m

Coupling Length 297 mm Joint Yield Strength 6.25 x1000 kN Optimum 26,700 N • m

Connection ID 194.31 mm Internal Pressure Capacity 76,900 kPa Maximum 29,400 N • m

Make-up Loss 128.65 mm Compression Efficiency 100 %


Shoulder Torques
Threads per inch 4 Compression Strength 6.25 x1000 kN
Minimum 4000 N • m
Connection OD Option Regular Max. Allowable Bending 58 °/100 ft
Maximum 22,700 N • m
External Pressure Capacity 58,100 kPa

Coupling Face Load 3514.09 kN Operation Limit Torques

Operating Torque 53,800 N • m

Yield Torque 82,800 N • m

Notes
This connection is fully interchangeable with:
Blue® - 8.625 mm - 0.4 / 0.45 / 0.557 / 0.595 / 0.625 / 0.687 mm
Connections with Dopeless® Technology are fully compatible with the same connection in its Standard version

For the lastest performance data, always visit our website: www.tenaris.com

Tenaris has issued this document for general information only, and the information in this document, including, without limitation, any pictures, drawings or designs (“Information”) is
not intended to constitute professional or any other type of advice or recommendation and is provided on an “as is” basis. No warranty is given. Tenaris has not independently verified
any information –if any- provided by the user in connection with, or for the purpose of, the Information contained hereunder. The use of the Information is at user’s own risk and Tenaris
does not assume any responsibility or liability of any kind for any loss, damage or injury resulting from, or in connection with any Information contained hereunder or any use thereof.
The Information in this document is subject to change or modification without notice. Tenaris’s products and services are subject to Tenaris’s standard terms and conditions or
otherwise to the terms resulting from the respective contracts of sale or services, as the case may be, between petitioner and Tenaris. For more complete information please contact a
Tenaris's representative or visit our website at www.tenaris.com . ©Tenaris 2022. All rights reserved.