You are on page 1of 10

Eurofins Product Testing A/S

Commission for Consumer Protection Smedeskovvej 38


8464 Galten
1 Vrabcha str. Denmark
1000 Sofia
BULGARIA CustomerSupport@eurofins.dk
www.eurofins.com

TEST REPORT
E-liquid
07 December 2021

1 Sample Information
Sample no. 392-2021-00475108
Product/Brand Name / Z-FIT PODS
Product EAN/Batch/Lot 850029648475
Manufacturer Details -
Importer Details -
Product type E-Liquid
Sample reception 30/09/2021
Unique Identifier PSA4_BG_153

2 Brief Evaluation of the Results

Test Result Conclusion Comment


Nicotine in e-liquids 10 Pass
Formaldehyde 20 Pass
Acetaldehyde 25 Pass
Acrolein 29 Fail Limit value given in AFNOR but not part of
the Tobacco Products Directive

Diacetyl <1 Pass


VOC Screening See section 8 -
Density See section 9 -
Details about test methods and results can be seen on the following pages.

<: Less than *: Not accredited


>: Greater than LOD: Limit of detection
Um(%): The expanded uncertainty Um(%) equals 2 x RSD%. For further information please visit www.eurofins.dk/uncertainty
The results are only valid for the tested sample(s).
This report may only be copied or reprinted in its entity,
392-2021-00475108_XSL_EN Page 1 of 10
3 Picture of Sample

4 Test Specification

CASP Ref Parameter Method Reference


8.4 Nicotine, PG, VG in e-liquid DS/ISO 20714: 2019, GC-FID
8.4 Aldehydes Internal Method, UHPLC-UV
8.4 VOC Screening Internal Method GC-MS
8.4 Diacetyl Internal Method, HS-GC-MS
- Density Internal Method, Gravimetric

<: Less than *: Not accredited


>: Greater than LOD: Limit of detection
Um(%): The expanded uncertainty Um(%) equals 2 x RSD%. For further information please visit www.eurofins.dk/uncertainty
The results are only valid for the tested sample(s).
This report may only be copied or reprinted in its entity,
392-2021-00475108_XSL_EN Page 2 of 10
5 Nicotine, Propylene glycol and Glycerol in e-liquids

Method Parameter CAS No. Limit of detection Uncertainty


(mg/ml) (Um)
Nicotine 54-11-5 0.2 20 %
DS/ISO 20714:2019
Propylene glycol 57-55-6 5 20 %
GC-FID
Glycerol 56-81-5 5 20 %

5.1 Description
The e-liquid sample is dissolved in isopropanol. The nicotine content of the diluted sample is then analyzed
by gas chromatography with flame ionization detection (GC-FID) and quantified according to a 6-point
calibration curve.

5.2 Reference
DS/CEN/TS 17287:2019

5.3 Results
Sample Parameter Content Limit Value Complies
(mg/ml) (mg/ml)
Nicotine 10 20 Pass
392-2021-00475108 Propylene glycol 390 - -
Glycerol 720 - -

5.4 Comment
-

<: Less than *: Not accredited


>: Greater than LOD: Limit of detection
Um(%): The expanded uncertainty Um(%) equals 2 x RSD%. For further information please visit www.eurofins.dk/uncertainty
The results are only valid for the tested sample(s).
This report may only be copied or reprinted in its entity,
392-2021-00475108_XSL_EN Page 3 of 10
6 Aldehydes in e-liquids

Method Parameter CAS No. Limit of detection Uncertainty


(mg/L) (Um)
Formaldehyde 50-00-0 1 20 %
Internal Method
Acetaldehyde 75-07-0 2 20 %
UHPLC-UV
Acrolein 107-02-8 2 20 %

6.1 Description
The e-liquid sample is dissolved in water and the extract is derivatized with 2,4-dinitrophenylhydrazine
(DNPH). The aldehyde content of the derivatized sample is then analyzed by ultrahigh performance liquid
chromatography with ultraviolet detection (UHPLC-UV) and quantified according to a 3-point calibration
curve.

6.2 Reference
Internal method (modified EPA 8315A)

6.3 Results
Sample Parameter Content Limit Value Complies
(mg/L) (mg/L)1
Formaldehyde 20 22 Pass
392-2021-00475108 Acetaldehyde 25 200 Pass
Acrolein 29 22 Fail
1
AFNOR XP D 90-300-2

6.4 Comment
-

<: Less than *: Not accredited


>: Greater than LOD: Limit of detection
Um(%): The expanded uncertainty Um(%) equals 2 x RSD%. For further information please visit www.eurofins.dk/uncertainty
The results are only valid for the tested sample(s).
This report may only be copied or reprinted in its entity,
392-2021-00475108_XSL_EN Page 4 of 10
7 Diacetyl in e-liquids

Method Parameter CAS No. Limit of detection Uncertainty


(mg/L) (Um)
Internal Method
Diacetyl 431-03-8 1 20 %
Headspace-GC-MS

7.1 Description
The e-liquid sample is dissolved in N,N’-dimethylformamide and the extract is analyzed directly using
headspace gaschromatography coupled to a mass selective detector (HS-GC-MS) and quantified
according to a 6-point calibration curve.

7.2 Reference
Internal method

7.3 Results
Sample Parameter Content Limit Value Complies
(mg/L) (mg/L)1
392-2021-00475108 Diacetyl <1 22 Pass
1
AFNOR XP D 90-300-2

7.4 Comment
-

<: Less than *: Not accredited


>: Greater than LOD: Limit of detection
Um(%): The expanded uncertainty Um(%) equals 2 x RSD%. For further information please visit www.eurofins.dk/uncertainty
The results are only valid for the tested sample(s).
This report may only be copied or reprinted in its entity,
392-2021-00475108_XSL_EN Page 5 of 10
8 VOC Screening of e-liquids

Method Parameter CAS No. Limit of detection Uncertainty


(mg/ml) (Um)
Internal Method GC-MS VOC Screening - 0.001 20 %

8.1 Description
The e-liquid sample is dissolved in isopropanol. The extract is then analyzed by gas chromatography with
mass selective detection (GC-MS) and quantified as n-Tetradecane (C14) equivalents. The screening is
semiquantitative.

8.2 Reference
Internal method

8.3 Results
Sample Component CAS No. ID Cat. Content
(mg/ml)
2-Butanol 78-92-2 2 0.15
Butanoic acid, ethyl ester 105-54-4 2 0.036
1-Butanol, 3-methyl-, acetate 123-92-2 2 1.1
Not Identified - 5 0.089
Not Identified - 5 0.14
3-Hexen-1-ol, (E)- 928-97-2 3 0.0099
Acetic acid 64-19-7 2 0.024
Benzaldehyde 100-52-7 2 0.018
Not Identified - 5 0.0092
2-Hydroxypropyl acetate 627-69-0 2 0.030
1,2-Propandiol (Propylenglycol, 57-55-6 2 48
Trimethylenglycol)
Not Identified - 5 0.060
392-2021-00475108 Not Identified - 5 0.019
Alfa-Terpinene 99-86-5 2 0.018
Acetic acid, phenylmethyl ester 140-11-4 2 0.062
2-Buten-1-one, 1-(2,6,6-trimethyl-1- 35044-68-9 3 0.015
cyclohexen-1-yl)-
Dipropylene glycol (1,1'-Oxybis-2- 110-98-5 2 0.039
propanol)
1,3-Dioxolane, 4-methyl-2-phenyl- 2568-25-4 2 0.024
Not Identified - 5 0.085
Nicotine 54-11-5 1 10
Not Identified - 5 0.052
Maltol 118-71-8 2 0.14
Not Identified - 5 0.014
2-Propenoic acid, 3-phenyl-, methyl 1754-62-7 3 0.033
<: Less than *: Not accredited
>: Greater than LOD: Limit of detection
Um(%): The expanded uncertainty Um(%) equals 2 x RSD%. For further information please visit www.eurofins.dk/uncertainty
The results are only valid for the tested sample(s).
This report may only be copied or reprinted in its entity,
392-2021-00475108_XSL_EN Page 6 of 10
Sample Component CAS No. ID Cat. Content
(mg/ml)
ester, (E)-
Not Identified - 5 0.061
Not Identified - 5 0.0080
Not Identified - 5 0.038
Glycerin 56-81-5 2 77
Not Identified - 5 0.077
Not Identified - 5 0.013
Benzoic acid 65-85-0 2 31
Not Identified - 5 0.17
Not Identified - 5 0.11
Not Identified - 5 0.011
Vanillin 121-33-5 3 0.21
Not Identified - 5 0.020
Not Identified - 5 0.013
Not Identified - 5 0.034
Not Identified - 5 0.056
Not Identified - 5 0.024
(Z)-4-phenyl-3-butene-1,2,3-triol 1319-88-6 2 0.015
2-Butanone, 4-(4-hydroxyphenyl)- 5471-51-2 2 0.36
Not Identified - 5 0.26

8.4 Explanation of ID Category


2: Identified by comparison with a mass spectrum obtained from library and supported by other information.
Quantified as tetradecane equivalent.
3: Identified with a lower match by comparison with a mass spectrum obtained from a library. Quantified as
tetradecane equivalent.
5: Not identified, quantified as tetradecane equivalent.

8.5 Chromatograms
A chromatogram of the screening is shown on the next page

<: Less than *: Not accredited


>: Greater than LOD: Limit of detection
Um(%): The expanded uncertainty Um(%) equals 2 x RSD%. For further information please visit www.eurofins.dk/uncertainty
The results are only valid for the tested sample(s).
This report may only be copied or reprinted in its entity,
392-2021-00475108_XSL_EN Page 7 of 10
8.6 Comment
-
<: Less than *: Not accredited
>: Greater than LOD: Limit of detection
Um(%): The expanded uncertainty Um(%) equals 2 x RSD%. For further information please visit www.eurofins.dk/uncertainty
The results are only valid for the tested sample(s).
This report may only be copied or reprinted in its entity,
392-2021-00475108_XSL_EN Page 8 of 10
9 Density of e-liquids

Method Parameter Limit of detection Uncertainty


(g/ml) (Um)
Internal Method Gravimetric Density - 5%

9.1 Description
The density of the e-liquid is determined using a 2-fold measurement.

9.2 Reference
Internal method

9.3 Results
Sample Parameter Density
(g/ml)
392-2021-00475108 Density 1.1

9.4 Comment
-

<: Less than *: Not accredited


>: Greater than LOD: Limit of detection
Um(%): The expanded uncertainty Um(%) equals 2 x RSD%. For further information please visit www.eurofins.dk/uncertainty
The results are only valid for the tested sample(s).
This report may only be copied or reprinted in its entity,
392-2021-00475108_XSL_EN Page 9 of 10
10 Appendix - Decision rules and Report version
10.1 Decision Rules
Eurofins Product Testing A/S, declare statement of conformity based on the “Binary Statement for Simple
Acceptance Rule” described in ILAC’s “Guidelines on decision Rules and Statements of Conformity” ILAC-
G8:09/2019.

This means that results above the detection limit are always reported with two significant digits. Results are
evaluated with the same number of significant digits as the corresponding limit values, and conformity is
based on results being less than or equal to limit values.

For limit values with more than two significant digits, the third digit will be used to confirm whether a result
is below or equal to the limit value. It will always be indicated in the evaluation table if this expanded
evaluation is performed.

For further information please visit www.eurofins.dk/product-testing/om-os/beslutningsregler/

10.2 Version History


Report date Report number Modification
07/12/2021 392-2021-00475108_XSL_EN Current version

<: Less than *: Not accredited


>: Greater than LOD: Limit of detection
Um(%): The expanded uncertainty Um(%) equals 2 x RSD%. For further information please visit www.eurofins.dk/uncertainty
The results are only valid for the tested sample(s).
This report may only be copied or reprinted in its entity,
392-2021-00475108_XSL_EN Page 10 of 10

You might also like