OPERATING INSTRUCTIONS
- 16 -
6.7 The anode output voltage can be read by using a selector
switch.
6.8 It is good practice to check the (current) digital displays
periodically.
6.9 When the anodes have nearly reached the end of their
design life the wear probe will activate and an audio-visual
alarm will go off in the panel. The audio alarm can be
stopped by pressing the reset button briefly and releasing but
the visual alarm will remain till the anode is replaced.
6.10 The approximate remaining life after the alarm goes off is TWO
MONTHS. However, this is approximate and care should be
taken to ensure that in case there is a delay beyond 2 months
after the alarm goes off in dry docking or anode
replacements the particular module should be shut off.
6.11 ENSURE SPARE ANODES ARE RE-ORDERED IN TIME. Please
quote the ORDER Reference while re-ordering.
6.12 The design life of the anodes 2.0 Years