Approved Test Leads For Panduit Mini-Com® TX6™

PLUS Jack Modules and DP6™ PLUS Patch Panels


Approved: Panduit independently verifies field testers report values consistent with a Laboratory Network Analyzer for adherence to the standards. The following testers are fully approved:

Permanent Link

Software Calibration Personality


Firmware Version Autotest Test Leads Comments
Version Equipment Module
DSP-43001 Software:
V1.925 Standards: Linkware
Part # DSP- Part # DSP-
V5.17 Software 1. Consult Fluke Networks' web site for the latest Firmware and Software
Fluke: Networks DSP- PCAL LIA101
DSP-41001 Software: V6.0 or TIA Cat 6 Version.
4000 Series Cable Universal Universal
V4.925 Standards: later Perm. PM06 2. It is STRONGLY RECOMMENDED that the DSP-LIA101 Adapters are
Analyzer Permanent Permanent
V5.17 (Windows 7 Link calibrated using this Kit and the Linkware Software (DSP Utilities/
Fluke Networks Website Link Calibration Link Interface
DSP-40001 Software: patch if Permanent Link Cal.) prior to Permanent Link testing.
Kit2 Adapter
V3.925 Standards: applicable)
V5.17
Linkware
Part # DTX-
Software
Fluke: Networks DTX- PLA001 or 002 1. Consult Fluke Networks' web site for the latest Firmware and Software
V6.0 or TIA Cat 6
1800 Series Cable Universal Version.
Software: V2.24 or later later - Perm. PM06
Analyzer Permanent 2. It is STRONGLY RECOMMENDED that the tester is calibrated prior to
(Windows 7 Link
Fluke Networks Website Link Interface testing.
patch if
Adapter
applicable)
1. Consult Agilent's web site for the latest Software Version.
WireScope 2. Calibration with the Precision Calibration Cable is STRONGLY
Pro RECOMMENDED.
Agilent: WireScope Pro Part # N2644A-
(ScopeData 3. Tester holds last calibration. Tester must be recalibrated if using a
N2640A WireScope Pro 101 Universal
Pro II) _ Cat6: Link N/A different DualRemote, upgrading the software, when transitioning from
Agilent Technologies Software 2.1.9 or later Cat 6A Link
Software Cat7/Class F copper cable test to Cat6A/Class E or lower performance
Website SmartProbes
2.19 or categories, or after 30 days.
later1 4. Universal Cat 6A Link SmartProbes should be in optimal condition.
See owners manual.

1.Consult Agilent's web site for the latest Software Version.


Agilent: N2600A 2. Calibration with the Precision Calibration Cable is STRONGLY
Part # N2604A- Part # N2604A-
WireScope 350 N2610A WireScope RECOMMENDED.
WireScope Software 301 Precision 101 Universal
FrameScope 350 Software Cat6: Link N/A 3. Tester holds last calibration. Tester must be recalibrated for switching
3.1 or later Calibration Cat 6 Link
Agilent Technologies 3.1 or later1 testing from Channel to PL.
Cable2 Smartprobe
Website 4. Universal Cat 6 Link Smartprobe should be in optimal condition. See
owners manual.

Ideal: LANTEK 6
LANTEK Twisted Part # 0012-
LANTEK 6A 1. Consult Ideal's web site for the latest Firmware and Software Version.
Firmware: V2.510 or Reporter Panduit Patch Pair 00-0629
LANTEK 7 N/A 2. Tester must be recalibrated from job site to job site.
later V3.270 or Cord UTPSP* Perm: Cat Cat6/5e
LANTEK 7G 3. Patch cords should be in optimal condition.
later 6-250 adapter RJ45
Ideal Industries Website
Channel

Software Calibration Personality


Firmware Version Autotest Test Leads Comments
Version Equipment Module

DSP-43001 Software: Part # DSP-


V1.925 Standards: Linkware LIA012
V5.17 Software Cat6/5e
Fluke: Networks DSP-
DSP-41001 Software: V6.0 or Channel
4000 Series Cable TIA Cat 6 1. Consult Fluke Networks' web site for the latest Firmware and Software
V4.925 Standards: later - Adapters or N/A
Analyzer Channel Version.
V5.17 (Windows 7 Part # DSP-
Fluke Networks Website
DSP-40001 Software: patch if LIA013 Cat 6
V3.925 Standards: applicable) Channel/Traffic
V5.17 Adapter
Linkware
Part # DTX-
Software
Fluke: Networks DTX- CHA001 or 1. Consult Fluke Networks' web site for the latest Firmware and Software
V6.0 or
1800 Series Cable TIA Cat 6 CHA001A Version.
Software: V2.24 or later later - N/A
Analyzer Channel Cat 6 / Class E 2. It is STRONGLY RECOMMENDED that the tester is calibrated prior to
(Windows 7
Fluke Networks Website Channel testing.
patch if
Adapter
applicable)
1. Consult Agilent's web site for the latest Software Version.
2. Calibration with the Precision Calibration Cable is STRONGLY
WireScope
Part # N2644A- RECOMMENDED.
Agilent: WireScope Pro Pro
100 Universal 3. Tester holds last calibration. Tester must be recalibrated if using a
N2640A WireScope Pro (ScopeData Cat6:
_ Cat 6A N/A different DualRemote, upgrading the software, when transitioning from
Agilent Technologies Software 2.1.9 or later Pro II) Channel
Channel CaT7/Class F copper cable test to Cat6A/Class E or lower performance
Website Software
SmartProbe categories, or after 30 days.
2.19 or later
4. Universal Cat 6A Channel SmartProbes should be in optimal
condition. See owner’s manual.
Agilent: N2600A
Panduit Part # N2604A-
WireScope 350 N2610A WireScope 1.Consult Agilent's web site for the latest Software Version.
WireScope Software Patch Cord Cat6: 100 Universal
FrameScope* 350 Software N/A 2. Tester holds last calibration. Tester must be recalibrated for switching
3.1 or later UTPSPI7 or Channel Cat 6 Channel
Agilent Technologies 3.1 or later testing from PL to Channel.
UTPSP7 Smartprobe1
Website

Ideal: LANTEK 6
LANTEK Twisted Part # 0012-
LANTEK 6A Panduit 1.Consult Ideal's web site for the latest Firmware and Software Version.
Firmware: V2.510 or Reporter Pair 00-0629
LANTEK 7 Patch Cord N/A 2. Tester must be recalibrated from job site to job site.
later V3.270 or Channel: Cat6/5e
LANTEK 7G UTPSP* 3. Patch cords should be in optimal condition.
later Cat 6-250 adapter RJ45
Ideal Industries Website

Part # 6331-
Megger TIA Cat 6 827 1. Consult Megger web site for the latest Firmware and Software
Megger: SCT2000 Version 1.0.0 - N/A
LCMD Channel Category 6 Version.
Channel
Adapter

* Panduit has not physically tested the FrameScope 350. Agilent maintains the FrameScope and WireScope have identical software and hardware for cabling testing.
Approved Test Leads For Panduit Mini-Com® TX6™
PLUS Jack Modules and DP6™ PLUS Patch Panels
Approved: PANDUIT independently verifies field testers report values consistent with a Laboratory Network Analyzer for adherence to the standards. The following testers are fully approved:

Permanent Link

Software Calibration Personality


Firmware Version Autotest Test Leads Comments
Version Equipment Module
Linkware
Part # OMNI-
Software
LIA101
Fluke: Networks V6.0 or TIA Cat 6
Universal 1. The PM25 may also be used to test Panduit TP style jacks and DP6™
OMNIScanner 2 Version 6.12 or later later - Perm. PM06
Permanent PLUS panels.
Fluke Networks Website (Windows 7 Link
Link Interface
patch if
Adapter
applicable)

Channel

Linkware
Software Part # 8262-42
Fluke: Networks V6.0 or Category 1. IMPORTANT: Make sure Channel adapters are used with Channel
TIA Cat 6
OMNIScanner 2 Version 6.12 or later later - 5/5e/6 N/A Autotests.
Chan1
Fluke Networks Website (Windows 7 Channel 2. Testing Channel on drops less than 20m is NOT RECOMMENDED.
patch if Adapter2
applicable)
4/8/10