Roll No Group Topic

203221007
1 Design of 6 storey RCC building of L- shape plan. Each wing outer dimensions 30 m long and 10 m wide . Location Pune
203221015
203221024
2 Design of industrial building with Northern light type roofing. Area Plan 45 m x 20 m. EOT of 5 ton capacity. Location Kharagpur
203221008
203221011
3 Design of industrial building of PEB type with Grid Truss roofing. Area Plan 45 m x 20 m. EOT of 5 ton capacity. Location Bhilai
203221022
203221006
4 Design of Pratt Truss through-type double track railway bridge, each span of 20 m. Location across River Mahananda near Jalpaiguri
203221005
203221019
5 Design of 30 m circular plan building with a spherical steel dome roof of rise 5 m, having a skylight opening of 1.5 m diameter at apex. Location Agartala
203221021
203221026
6 Analysis of 6 storey RCC building of plus-shape plan. Each wing outer dimensions 15 m long and 10 m wide. Location Mysuru
203221013
203221003
7 Analysis of 6 storey Steel building of plus-shape plan. Each wing outer dimensions 15 m long and 10 m wide. Location Kochi
203221027
203221020
8 Design of circular plan building with a spherical steel dome roof of rise 5 m, having a skylight opening of 1.5 m diameter at apex. Location Agartala
203221028
203221009
203221010 9 Design of RC T-girder deck-type double BG track railway bridge, each span of 15 m. Design also the abutment and wing walls. Location across River Netravati near Mangaluru
203221023
203221025
10 Design of 50 m x 10 m rectangular plan building with a cylindrical steel vault roof of rise 5 m. Location Baramulla
203221001
203221018
11 Design of industrial building of PEB type with rafter beams. Area Plan 45 m x 20 m. EOT of 5 ton capacity. Location Balharshah
203221004
203221002
12 Design of 6 storey Steel building of L- shape plan. Each wing outer dimensions 30 m long and 10 m wide . Location Coimbatore
203221012

1. All other details than as given in the topic should be assumed appropriately
2. Layout plans within the dimensions specified can be given logically.
3. All designs should include the design of the substructures such as foundations, piers etc (design of piles and pile caps for bridges need not be done) Buildings SBC 200 kPa
4. Topics given on design of roof systems should include the design of the structure below as well, all the way upto the foundation, including base plates and pedestals
5. Wind and earthquake loads should be taken based on the location given. For bridge designs, the relevant RDSO loading should be adopted but hydrodynamic loads such as drag, scour etc
need not be considered
6. For earthquake design, all frames can be designed as OMRF and the basic provisions of IS:13920-2016 alone can be followed. Static equivalent method can be adopted for design and
pushover analysis is not necessary

7. All submissions should include an introductory section explaining the given problem, the layout and other details decided by you (including materials adopted), the modelling strategy,
analysis types used, loads and load combinations, load calculations, representative analysis results such as a BMD/SFD of interest, sample design calculations of each type of structural
element and properly made structural drawings and detailing. Drawings in AutoCAD are preferred though manual drawings are accepted as long as they are well-dimensioned, legible and neat