You are on page 1of 2

L I N EAR ELECT R O N A C C E L E R ATO R

УЭЛР - 6 - 1 -Д-
-Д-4-01

- Cooling system providing


constant temperature of
cooling liquid;

- Control console;
- Cables (including high
voltage) and hoses.

The accelerator is operated in


three main modes:

- Low energy mode (all pulses


with low energy)

- High energy mode (all pulses


with high energy)
- Dual energy mode (all even
pulses with high energy and
all odd pulses with low energy)

The radiation source repre- The linear electron accelerator


sents itself a linear electron with pulse-to-pulse energy
accelerator УЭЛР-6-1-Д-4-01 modulation consists of:
(ТУ 6912-001-69564325-2011)
manufactured by «Scantronic - X-ray head, including: elec-
Systems». tron gun, accelerating struc-
ture, waveguide with system
The accelerator is intended for of insulating gas feeding, low
use as a source of bremsstrahl- power radiofrequency system,
ung with boundary energy vacuum system, target, local
corresponding to the energy of radiation shielding, ion cham-
accelerated electron beam that ber, elements of cooling
used for generating of shadow system, control electronics
x-ray image of a scanned (controllers and controlling
object. computer), interfaces for
connection with other
The accelerator is one of the systems, hermetic case;
basic and essential parts of
inspection system; its param- - Modulator, combined with
eters define basic physical and X-ray head in one-piece unit;
technical performances of
inspection system.
Technical specifications
Electron beam high energy 6 MeV (±5%)
Electron beam low energy 3,5 MeV (±5%)

Dose rate at high energy 2,0 Gy/min at 1 m (±10%)


Dose rate at low energy 2,0 Gy/min at 1 m (±10%)
Dose rate at dual energy 4,0 Gy/min at 1 m (±10%)

Repetition rate in high energy mode 200 Hz


Repetition rate in low energy mode 200 Hz
Repetition rate in dual energy mode 2х200 Hz

Range of time delay between pulses with high and low energy 200 – 495 μsec

Stability of high energy 0,5%


Stability of low energy 0,5%
Dose rate stability at high energy 2%
Dose rate stability at low energy 2%

Focal spot size < 2 mm

Missing pulse probability ≤ 5х10-3


Probability of two sequent pulses missing ≤ 1х10-4

Radiation leakage 2х10-5 at 6 MeV

Collimator slit width 3 mm

Angle of beam aperture in overhead direction +33,5°


Angle of beam aperture in bottom direction -18,7°

Dimensions of radiator with modulator 1090х640х1460 mm


Weight of radiator with modulator < 1500 kg

Control console dimensions 300х400х180 mm


Control console weight < 10 kg

Chiller dimensions 750х1700х1535 mm


Chiller weight < 250 kg

Power supply 400 V /3 phases/ 50 Hz

Power consumed by x-ray head and modulator 13 kW


Power consumed by chiller (at warming-up) 8 kW

Operation conditions:
Air temperature 0°С / +45°С
Air humidity 5% - 95%
Warming-up time < 15 min

Scantronic Systems Ltd.


10/3, Radio str., Moscow, 105005, Russia, e-mail: info@scantronicsystems.com