Professional Documents
Culture Documents
ASIA ASIA
1)
• Fig.3: Full Subrack
Each half rack can operate in own Duplex mode (TDD/FDD
convergence in one Subrack)
AMIA Subrack 1)In FL/TL16A, full subrack configuration is seen as twological eNBs, each
composed of half subrack. In Future releases, full subrackwould be supported
as one logical eNB.
LTE2114 AirScale Common ASIA
Interfaces
Common plug-in unit:
SIN
EIF5 • Centralized control processing
DC-IN EAC SOUT SEI1 SEI2 SRIO1 EIF1 EIF3
• Up to 2 units in one Subrack for
independent Base Stations or high
capacity configurations
• Integrated Ethernet transport
termination per subrack side
Connectivity to:
• Transport ( EIF
)
• External System Module Extension
•AirScale SM Subrack ( SEI )
SRIO2 EIF2 EIF4 LMP
•Flexi Multi Radio 10 SM ( SRIO )
• AirScale System Module is protected with HW Activation License Key (HWA LK) Sales Item (SI)
• ABIA in basic extent (50% of BB capacity is available, remaining 50% is disabled) requires 1x HWA LK
• ABIA in full extent (100% of BB capacity) requires 2x HWA LK
Number of licenses
vs. Cell type
ABIA available capacity (#cells)
4 8 5/10 2/2
2 4 5/10/15/20 4/4
• AirScale SM requires in minimum 1 license (1x ABIA in basic extent per AMIA) and up to 12 licenses (6x ABIA in full extent per
AMIA)
Usage of ABIA RF ports
ABIA • Each Capacity Extension module ABIA provides 6 optical
RF ports
• OBSAI: 3 or 6 Gbps
• FDD BTS configurations are defined as building blocks (= Cell Sets) that can be combined with each
other to build a full BTS configuration
Up to two basic cell sets per ABIA One extended cell sets per ABIA
Up to two basic cell sets per module: One extended cell set per module:
• both cell sets share 6 ports • up to 6 ports can be used
• One cell set can utilize max 4 ports, leaving 2 ports for • configurations in extended cell set are mainly defined to
the other allow ULCoMP and SuperCell between cells
ABIA ABIA
Basic cell set configuration Mixture of different basic cell
sets can be handled by same Mixture of different cell sets (basic and extended) can be
e.g. 3 x 20 MHz on OBSAI RUs
ABIA handled within same AirScale System Module
Up to the maximum capacity of AirScale System Module (in
terms of supported number of ABIA units)
• Note:
• All Radio Units connected to same ABIA must use t he same
interface technology, either OBSAI or CPRI
• One AirScale System Module can handle cell sets built on Basic cell set configuration
different Radio Unit types, i.e. OBSAI and CPRI e.g. 3 x 20 MHz on OBSAI RUs
Example of configuration for AirScale SM
Single band
Sector5 Sector5 Sector6 Sector6
5/10/15/20 MHz LCR5:Tx&Rx LCR5:TxRx
Band A/B/C LCR6:Tx&Rx LCR6:TxRx
Band A/B
5/10MHz
OBSAI 6Gbps
Sector1 Sector1 Sector2
Sector3 Sector2 Sector1 Sector2
LCR1:Tx&Rx LCR1:TxRx LCR2:Tx&Rx
LCR3:Rx LCR2:Rx LCR1:Rx LCR2:TxRx
Band A 5/10/15/20MHz
Feature description:
• Flexi outdoor cabinet for AirScale System Module Height 600mm
• 4U internal space Width 380mm
• Power distribution for interior equipment Depth 600mm
• Installation options:
Weight Max 29 kg without site bac (Site bag 9 kg)
• Horizontal and vertical
Ingress Protection IP55
• Pole/wall/floor and stand alone installations
• Stackable of horizontal installation Operating Temperature -40°C ~ +55°C
• Stackable with Flexi modules (Top or bottom of Flexi)
Installation Temperature -20°C - +55°C
• The cabinet has the following functions:
• protection against external damage and foreign objects Airflow Direction Front side to back side
• The FCOB provides earthquake protection for internal modules Cold start ~2h from -40°C to -5°C
Nominal supply voltage -40.5 … -57 V DC
Input voltage range Extended Service Voltage Range supported -3 6Vdc .. -60Vdc Floating
Volume 136.8L
Mass capacity Support Max 25Kg module inside
P ow er co ns ump tio n M in 30 W, T yp ic al 50 W , M ax (h ot ) 1 50 W, Co ld st ar t ( he at in g) 60 0W
FCOB cabinet
FCOB cabinet with with closed door
opened door
PIN No FCOB SIDE REMARKS BTS Com BTS Alarm Cable Position
1
2 EXT-ALARM1 MAIN FAIL LINE ID 5 MAIN FAIL from Rectifier to FCOB
3
4 EXT-ALARM2 RECTI FAIL LINE ID 6 RECTI FAIL from Rectifier to FCOB
5
6 EXT-ALARM3 LOW LOAD LINE ID 7 LOW BATT from Rectifier to FCOB
7
8 EXT-ALARM4 HIGH TEMP LINE ID 8 HIGH TEMP from Rectifier to FCOB
9
10 EXT-ALARM5 GENSET RUN LINE ID 9 GENSET RUN from Rectifier to FCOB
11
12 EXT-ALARM6 BATT CAGE LINE ID 10 BATT CAGE from Rectifier to FCOB
13
14 EXT-ALARM7 DOOR OPEN LINE ID 11 DOOR OPEN from Rectifier to FCOB
15
16 EXT-ALARM8 N/A N/A N/A N/A
T1
T2 TEMP SENSOR HIGH TEMP LINE ID 2 HIGH TEMP from internal FCOB
D1
D2 DOOR OPEN DOOR OPEN LINE ID 1 DOOR OPEN from internal FCOB