You are on page 1of 1

A B C

2F BEAM SCHEDULE (CONCRETE = 21 MPA :Fy = 275 MPA)


4030 2850
BEAM SIZE BOTTOM REINFORCEMENT TOP REINFORCEMENT SHEAR STIRRUPS
SFR
NUMBERS B D LEFT MID SPAN RIGHT LEFT MID SPAN RIGHT LEFT MID SPAN RIGHT
B1 250 400 2-Ø16 2-Ø16 3-Ø16 3-Ø16 3-Ø16 3-Ø16 11-2L-Ø10@80 C/C 16-2L-Ø10@125 C/C 11-2L-Ø10@80 C/C -
+ +
2-Ø16 2-Ø16
B2 250 400 3-Ø16 2-Ø16 3-Ø16 3-Ø16 3-Ø16 3-Ø16 11-2L-Ø10@80 C/C 6-2L-Ø10@125 C/C 11-2L-Ø10@80 C/C -
+ +
2-Ø16 2-Ø16
B1 B2 B3 300 450 4-Ø16 4-Ø16 4-Ø16
+
4-Ø16 4-Ø16
+
4-Ø16 11-2L-Ø10@95 C/C 12-2L-Ø10@150 C/C 11-2L-Ø10@95 C/C -
4 2-Ø16 4-Ø16
C1 C2 C3 B4 300 450 4-Ø16 4-Ø16
+
4-Ø16
2-Ø16
+
4-Ø16
4-Ø16
4-Ø16
+
4-Ø16
2-Ø16
11-2L-Ø10@95 C/C 4-2L-Ø10@150 C/C 11-2L-Ø10@95 C/C -
B5 250 350 2-Ø16 2-Ø16 2-Ø16 2-Ø16 2-Ø16 2-Ø16 9-2L-Ø10@115 C/C 7-2L-Ø10@115 C/C 9-2L-Ø10@115 C/C -
B6 250 350 2-Ø16 2-Ø16 2-Ø16 2-Ø16 2-Ø16 2-Ø16 9-2L-Ø10@115 C/C 7-2L-Ø10@115 C/C 9-2L-Ø10@115 C/C -
B22
B21

B26
B16

B7 300 450 3-Ø16 3-Ø16 3-Ø16 4-Ø16 4-Ø16 4-Ø16 11-2L-Ø10@95 C/C 12-2L-Ø10@150 C/C 11-2L-Ø10@95 C/C -
2850

+ +
2-Ø16 2-Ø16
B8 300 450 4-Ø16 4-Ø16 4-Ø16 4-Ø16 4-Ø16 4-Ø16 11-2L-Ø10@95 C/C 4-2L-Ø10@150 C/C 11-2L-Ø10@95 C/C -
+ + +
2-Ø16 2-Ø16 2-Ø16
B9 250 400 2-Ø16 2-Ø16 2-Ø16 3-Ø16 3-Ø16 3-Ø16 11-2L-Ø10@80 C/C 16-2L-Ø10@125 C/C 11-2L-Ø10@80 C/C -
B3 B4 B10 250 400 2-Ø16 2-Ø16 3-Ø16 3-Ø16 3-Ø16 3-Ø16 11-2L-Ø10@80 C/C 6-2L-Ø10@125 C/C 11-2L-Ø10@80 C/C -
3 B11 250 350 2-Ø16 2-Ø16 2-Ø16 3-Ø16 3-Ø16 3-Ø16 12-2L-Ø10@115 C/C 10-2L-Ø10@115 C/C 12-2L-Ø10@115 C/C -
C4 C5 C6 B12 250 350 2-Ø16 2-Ø16 2-Ø16 3-Ø16 3-Ø16 3-Ø16 9-2L-Ø10@115 C/C 7-2L-Ø10@115 C/C 9-2L-Ø10@115 C/C 1-Ø16EF
B13 250 400 2-Ø16 2-Ø16 2-Ø16 3-Ø16 3-Ø16 3-Ø16 2-2L-Ø10@115 C/C 2-2L-Ø10@115 C/C 2-2L-Ø10@115 C/C 3-Ø16EF
+ + +
2-Ø16 2-Ø16 2-Ø16
B5 B6 B14 250 400 3-Ø16 2-Ø16 3-Ø16 3-Ø16 3-Ø16 3-Ø16 11-2L-Ø10@80 C/C 4-2L-Ø10@125 C/C 11-2L-Ø10@80 C/C -
B15

+ +
B17

B20

B25
2-Ø16 2-Ø16
3000

B15 250 400 3-Ø16 2-Ø16 3-Ø16 3-Ø16 3-Ø16 3-Ø16 11-2L-Ø10@80 C/C 7-2L-Ø10@125 C/C 11-2L-Ø10@80 C/C -
+ +
2-Ø16 2-Ø16
B16 250 400 3-Ø16 2-Ø16 3-Ø16 3-Ø16 3-Ø16 3-Ø16 11-2L-Ø10@80 C/C 6-2L-Ø10@125 C/C 11-2L-Ø10@80 C/C -
+ +
2-Ø16 2-Ø16
B7 B8 B17 300 400 4-Ø16 4-Ø16 4-Ø16 3-Ø16 3-Ø16 3-Ø16 8-2L-Ø10@140 C/C 6-2L-Ø10@140 C/C 8-2L-Ø10@140 C/C -
2 B18 250 400 3-Ø16 2-Ø16 2-Ø16
+
3-Ø16
+
3-Ø16
+
3-Ø16 2-2L-Ø10@125 C/C 2-2L-Ø10@125 C/C 2-2L-Ø10@125 C/C 3-Ø16EF
C7 C8 C9 2-Ø16 2-Ø16 2-Ø16
B19 250 400 3-Ø16 2-Ø16 3-Ø16 3-Ø16 3-Ø16 3-Ø16 11-2L-Ø10@80 C/C 4-2L-Ø10@125 C/C 11-2L-Ø10@80 C/C -
+ +
2-Ø16 2-Ø16
B20 250 400 3-Ø16 2-Ø16 3-Ø16 3-Ø16 3-Ø16 3-Ø16 11-2L-Ø10@80 C/C 7-2L-Ø10@125 C/C 11-2L-Ø10@80 C/C -
+ +
B14

B19

B24
2-Ø16 2-Ø16
2614

B21 250 400 3-Ø16 2-Ø16 3-Ø16 3-Ø16 3-Ø16 3-Ø16 11-2L-Ø10@80 C/C 6-2L-Ø10@125 C/C 11-2L-Ø10@80 C/C -
+ +
2-Ø16 2-Ø16
B22 250 300 2-Ø16 2-Ø16 2-Ø16 2-Ø16 2-Ø16 2-Ø16 10-2L-Ø10@100 C/C 8-2L-Ø10@100 C/C 10-2L-Ø10@100 C/C -
B9 B10 B23 250 400 2-Ø16 2-Ø16 2-Ø16
+
3-Ø16
+
3-Ø16
+
3-Ø16 3-2L-Ø10@95 C/C 1-2L-Ø10@95 C/C 3-2L-Ø10@95 C/C 2-Ø16EF
1 2-Ø16 2-Ø16 2-Ø16

B18

B23
C10 B11 C11 B12 C12 B24 250 400 3-Ø16 2-Ø16 3-Ø16 3-Ø16 3-Ø16 3-Ø16 11-2L-Ø10@80 C/C 4-2L-Ø10@125 C/C 11-2L-Ø10@80 C/C -
B13

+ +
2-Ø16 2-Ø16
B25 250 400 3-Ø16 2-Ø16 3-Ø16 3-Ø16 3-Ø16 3-Ø16 11-2L-Ø10@80 C/C 7-2L-Ø10@125 C/C 11-2L-Ø10@80 C/C -
+ +
2-Ø16 2-Ø16
B26 250 400 3-Ø16 2-Ø16 3-Ø16 3-Ø16 3-Ø16 3-Ø16 11-2L-Ø10@80 C/C 6-2L-Ø10@125 C/C 11-2L-Ø10@80 C/C -
+
2-Ø16
CIVIL ENGINEER: PROJECT TITLE / LOCATION: OWNER: CADD OPTR.: SHEET CONTENTS: REMARKS/REVISED: SHEET NO:
PTR NO.: 9894430 REG NO.:0122517
ST
DATE.: SECOND FLOOR FRAMING PLAN
TWO STOREY RESIDENTIAL
BUILDING CHECKED:
NHEL ADRIAN B. BARTOLINE ISSUED ON.: JANUARY 28, 2021 TIN NO.:441-590-802-000 MR. RONALDO F. ABETO
CIVIL ENGINEER DATE:
MRS. MYLENE M. ABETO
ISSUED AT:MANILA LOT 75, BLK. 1, 1483 MONGGO ST., NAPICO
MANGGAHAN, PASIG CITY
APPROVED:
DATE:
0 6