British Standard
Testing concrete
Part 206. Recommendations for
determination of strain in concrete
Essais du beton
Partie 206. Recommandations relatives a la determination des contraintes dans le beton
Foreword
Contents
Page
Foreword Inside front cover
Committees responsible Back cover
Recommendations
1 Scope
2 Definitions
3 General guidance
4 Common types of strain gauge and their use
5 Choice of device
6 Report
Figure
1 Types of device for measuring strain
BS 1881 : Part 206 : 1986
Recommendations
1 Scope the factors which will affect the accuracy and calibration of
the device and, where possible, check that the device is
This Part of BS 1881 gives recommendations on methods correctly calibrated by a method traceable t o the length
and devices which can be used t o determine strain in standards maintained by the National Physical Laboratory.
concrete. Some devices measure a propew directly related Eiectricai displacement transducers, for example, can be
t o strain in the gauge (e.g. electrical resistance gauges) calibrated using a micrometer complying with BS 870.
whereas others actually measure displacement, which can I t should always be borne in mind that a strain gauge
be used to determine strain using a known base length measures the strain in the gauge length only. The necessity
(e.g. displacement transducers). References t o strain gauges for care in locating the gauges onto (or into) the concrete
in this Part include both types of device. cannot be over-emphasized, whether they be tocated on
The use of the following devices is described: lugs, stuck to or clamped onto the surface, or cast into the
(a) mechanical (including mechanical/optical); concrete. The effects of local strain concentrations and
(b) electrical resistance (metal and alloy elements); gradients should be borne in mind.
f o r general purpose strain measurement of a concrete
(c) vibrating wire (acoustic];
structure, a gauge length less than about four times the size
(d) electrical displacement transducers. of the largest aggregate particle is likely to be affected by
NOTE.The titles of the publications referred to in this standard are local variations in the mix.
listed on the inside back cover.
For measuring strains in different directions at the same
location, electrical resistance gauges are available in the
form of rosettes and can be used as single 2-way devices or
2 Definitions single 3-way devices, depending upon whether or not the
For the purposes of this Part of BS 1881 the definitions principal strain axes are known. Similar arrangements can
given in BS 6100 : Part 6 apply, together with the following. be contrived with other gauges.
2.5 gauge factor. Constant by which the reading from the 4.q .2 Gauge length and discrimination. Types of mechanical
gauge has to be multiplied to derive the strain. gauge are available in a wide range of gauge lengths,
from 12 mm t o 2000 mm. The discrimination of any type
of gauge normally increases with gauge length and can vary
from 50 microstrain to 2 microstrain per division of the
3 General guidance scale.
There are several aspects which are common t o all gauges. 4.1.3 Mounting the gauge. The studs. etc., should be so
The most important consideration for any type of gauge fixed that the gauge locates on the reference points
is that the operator should he experienced in i t s use. symmetrically. Out-of-alignment can give misleading results.
Characteristics and limitations of various devices and The adhesive chosen should be such, and applied in such a
systems should always be carefully studied before choosing way, that the movement of the concrete is directly reflected
the most appropriate. Careful note should be taken of the in the movement of the reference points.
manufacturer's instructions.
Sound parts of the sudace should be chosen and prepared
Owing to the different methods of application of these carefully by roughening and cleaning. To achieve reliable
devices. there i s no universal method of checking their results, bubbles in the adhesive should be avoided. For long-
accuracy. It is essential that the operator both be aware of term tests the reference points should be made of stainless
BS I881 : Part 206 : 1986
steel and covered with a film of grease when not in actual (b} the adhesive is carefully applied in a thin layer;
use. Grease should be removed before taking readings. (c) the adhesive i s free of air bubbles;
Under the conditions of exposure, neither the adhesive nor
(dl the adhesive i s fully cured, particularly in cold
the reference points should be such as to creep, degrade or
weather.
corrode. Cleanliness of the gauge and gauge reference points
cannot be over-emphasized. 4.2.3.2 Embedded gauges. Suitably encapsulated gauges can
be cast into the concrete. For guidance on the precautions
4.1.4 Precautions. For gauges which are clamped to the
to be taken see 4.2.4.
concrete,the pressure is critical. Most types of demountable
gauges should be held with two hands, and with all types an 4.2.4 Precautions. The relationship between strain and
even pressure should be maintained. It has been found that resistance wilf change with temperature, and gauges may
different operators can obtain different results and, be self-compensating or incorporate a thermocouple.
therefore, if subsequent readings are to be taken a t a later Alternatively, a dummy gauge can be used. Gauges should
date, it is recommended that the same operator should, be sited away from draughts and direct sunlight, although
if possible, take the readings. changes in ambient temperature wilf not normally affect
Temperature variations have to be taken into account, readings over a small time-scale. Gauges should be water-
both in the concrete and in the instrument. Variation can proofed if they are subject to changes of humidity, or for
be caused by handling, direct suniight, etc. For this reason long-termuse.
an invar steel bar is generally used either to form the main Background electrical noise and interference will seriously
frame of the gauge andfor to check the gauge each time it is affect the results. This may sometimes be reduced by
used. suitable shielding, wiring systems and instrumentation.
To allow for the effect of possible wear in the instrument Constant calibration i s needed to allow for drift.
or the invar bar, the latter should be checked either after Long-terminstability of gauges and adhesives limits their
every 1000 readings or yearly, whichever represents the suitability for long-term tests. The strain capacity will also
more frequent use, against a reference invar bar kept solely generally be small unless special 'post yield' gauges having
for this purpose. a high strain limit are used.
When the concrete is heated by artificial means, the gauge The use of these gauges requires considerable care, skill and
should be thermally shielded and insulated. experience if reliable results are to be obtained.
If the gauge is to be embedded, the elasticity of the
4.2 Electrical resistance gauges (metal and alloy elements) encapsulated gauge should be made approximately equal
4.2.1 Principle. This type of gauge i s in the form of a flat to the elasticity of the concrete for the period over which
gr@ of wires, or etched copper-nickel foil mounted on the measurements are to be taken.
thin plastics sheet, which is stuck to the t e s t surface
(see figure Itb)). Strain is measured by means of changes 4.3 Vibrating wire (acoustic) gauges
in electrical resistance resulting from extension and 4.3.1 Principle. A wire stretched between two points has a
compression of the gauge. The resistance changes can be fundamental resonant frequency. Changes in strain will
measured by a single Wheatstone bridge, which can be result in changes in the resonant frequency. This property is
connected to multichannel reading and recording devices. used to measure strain. The wire is excited by an electric
The relationship between strain and resistance for these pulse passed through an electromagnet situated close to the
gauges will be approximately linear and defined by the centre of the wire. The same magnet can then be used to
gauge factor. detect and transmit the vibration to a frequency measuring
Characteristicswill vary according to thegauge constructjon, device (see figure I (c)).
but foil gauges will generally be more sensitive than wire
4.3.2 Gauge length and discrimination. These gauges
gauges and have a higher heat dissipation, which reduces the
are commercially available in lengths from 12 mm up
effects of self -heating.
to 200 mm and have a discrimination of 1 microstrain
4.2.2 Gauge length and discrimination Commercial gauges to 10 microstrain.
are available in lengths from 0.2 mrn to 150 rnm, and their
4.3.3 Mounting the gauge. The gauge i s either securely
discrimination, depending on the measuring equipment.
anchored onto supports fixed in the specimen, or cast into
varies from 20 microstrain to 1 microstrain. These gauges
the concrete. In order to protect the wire against damage
are more often used than mechanical gauges over shorter
it is sealed in a tube af material, e.g. acrylic resin. If the
gauge lengths.
gauge is to be cast into the concrete, then a careful and
4.2.3 Mounting the gauge consistent procedure i s impartant to ensure that the gauges
are not displaced during concreting and that the concrete
4.2.3.1 Surface mountedgauges. The location, mounting
is fully compacted around them. It i s often helpful to
and protection of the gauge is critical. Care should be taken
encapsulate the gauges before use in 'dog-bones' of matching
to ensure that:
concrete, which should have no sharp corners and an
Ia) the surface i s free of dirt, grease, laitance and loose exposed aggregate finish.
material:
4.3.4 Precautions. I f the gauge is t o be embedded, Screened cable should be used between the gauge and the
the elasticity of the gauge should be so selected that it monitoring device t o counteract the effects of stray electro-
approximates t o the elasticity of the concrete for the magnetic fields. The usual precautions, well-known t o the
period over which the measurements are t o be taken. experienced engineer, which are necessary when dealing
The assembly of a gauge and the materials and workmanship with complicated electronic equipment should be observed.
are at1 important: there is no substitute for experience
when dealing with these gauges and the interpretation of
the results obtained. 5 Choice of device
Avoidance of magnetic fields, magnetic particles, physical
damage and corrosive infiuences, cannot be overemphasized. Careful consideration should be given t o the type of test,
Allowance should be made for the effect of temperature whether it is a laboratory or field test, short- or long-term,
due to the slightly different coefficients of thermal static or cyclic, and how rapidly changing if cyclic.
expansion of the wire and the concrete. Any gauge can be used under laboratory conditions
providedthat the relevant precautions are taken. Mechanical
4.4 Electrical displacement transducers gauges are preferred for tests carried out under outside
4.4.1 Principle, The movement of an armature i s measured exposure because of their robust nature and cheapness.
by i t s effects on the properties of a circuit in the main body Mechanical gauges are not suitable for embedment or use
of the transducer. Different principles are involved using under water, where vibrating wire gauges are appropriate.
changes in resistance, capacitance, inductance and so on. When a long-term test is undertaken, the effects of ageing
Each type of transducer requires compatible electronic and temperature on the performance of the gauge have t o
equipment to provide the necessary input and convert the be considered. Some adhesives used in mounting gauges are
output to a reading (see figure l (c)). subject to creep and chemical deterioration, and the supplier
should be consulted about the pedormance of the adhesive
4.4.2 Gauge length and discrimination. Commercial trans-
under the expected conditions of test. Mechanical and
ducers are available in a wide range of lengths and strokes. acoustic gauges, or transducers, are preferred for long-term
High discrimination i s usually obtained with short strokes tests, where fatigue life is important.
so the length and stroke should be chosen to suit the
particular application. Any gauge can be used for static tests, but the mechanical
and acoustic gauges are not recommended for tests where
4.4.3 Mounting the transducer. The transducer is fixed the rate of change of strain is faster than 1 microstrain per
between gauge points located on the surface of (or second. Electrical resistance gauges or transducers are better
embedded in) the concrete. An adjusting mechanism is for cyclic tests.
usually incorporated so that the transducer may be zeroed
before commencing a rest.
4.4.4 Precautions. A large amount of electrical equipment 6 Report
is necessary for supplying the input signal and monitoring,
The following information should be included in the report
modifying, filtering and amplifying the output signal.
of the investigation:
The user needs a great deal of experience if strains of the
order of 10 microstrain are to be measured. For example, (a) date, time and place of each test;
with many linear variable differential transformers (Ivdt) (b) description of the structure and its load history;
the input signal usually has a tow vottage (e.g. 5 V ) and a (c) locations of gauges, including whether surFace or
frequency of the order of 1 kHz to 5 kHz. The response embedded, with a dimensioned sketch;
time of thisgauge is directly proportional to this frequency,
(d) details of the concrete, including i t s condition at the
the measured frequency being up to onequarter of the
time of the investigation;
energizing frequency.
(e) environmental conditions;
When dynamic tests are being undertaken and the rate of
change of strain requires measurements at intervals closer (f type of gauge;
than 0.004 s, then an input signal of higher frequency than (g) method of attachment, including adhesive
1 kHz should be used. This response time of the measuring description if needed;
instrument should also be carefully noted. For example.
(h) gauge length, discrimination and details of
many Ivdt's now incorporate their own oscilla~orsand
calibration;
demodulators requiring a stable d.c. input and giving a d.c.
output. (il readings obtained and mean values, with appropriate
measure of variation,
Accurate location of the gauge and fitting is important.
The plate or disc which touches the end of the armature
should be friction-free and should be fixed firmly to the
concrete or to a reference device.
Publications referred to
BS 870 External micrometers
BS 907 Dial gauges for linear measurement
BS 1881 Testing concrete
Part 201 Guide to the use of nondestructive methods of test for hardened concrete
BS 6100 Glossary of building and civil engineering terms
Part 6 Concrete and plaster
This British Standard, having been prepared under the direction of implementing the standard, of necessary details such as symbols and
the Cement, Gypsum. Aggregates and Quarry Products Standards slze, type or grade designations. Enquiries should be addressed to
Committee. was published under the authoriw of the Board of BSI the Publications Manager, BSI, Linford Wood, Milton Keynes
and comes into effect on 31Oaober l996. MK14 6LE. The number for telephone enquiries i s 0908 220022
O British Standards Institution, 1986 and for telex 825777.
ISBN 0 580 15387 8 Contraci requirements. A British Standard does not purport to
The following BSI references relate t o the work on this standard: include all the necessary provisions of a contract. Users of British
Committee reference CAB14 Draft for comment 85114014 DC Standards are responsible for therr correct application.
British Standards Institution . 2 Park Street London W I A 2BS . Telephone 071-6299000 . Telex 266933
CABf4
9601 - 5 - 0 . l k - D P