You are on page 1of 3

MCU board

SBU board

BCU board

Basic Standards (MBD SB) & Suppl. Drawing No.: EN21C Surf. roughness Material / Blank:
EN21F-m Tolerances
Mass (kg) Final User Matrial:

Date Des. Chk. Appd. A.C. Change / Replacement


* Replaced by Ident No.: 9
8
7
6
5
4
3
2
1
20020508 DFA JHV JHV 0
Similar Drawing no.: Replacement for Ident no.:

Scale: Size: Type Page No.:


ALCU signal description MAN B&W Diesel A/S
1:1 A3 01 (03)
Info No. Description Ident. No.

This drawing is the property of MAN B&W Diesel A/S and is to be treated as confidential by the party to whom it has been submitted by 3 63 140 Control Unit. Cyl. Lub. 0789390-3
MAN B&W Diesel A/S and is not to be disclosed to any third party without the specific prior written permission of MAN B&W Diesel A/S Final User Info No. Final User Description Final User Ident. No.
ALCU MCU
LCD Input: LCD signal as potential free contact from Governor. For LCD Input X2:
J30:3,4
Electronic Governors. Input, pot. Free <- 1,2
SBU
Solenoid / Feedback: Activation of Solenoid valves for injection of lub. Oil. 1:Sol #xA, 2:Ret., 3:Sol #xB Solenoid / Feedback Cyl. 1…. Cyl. 12
L1..L12 X1:
Cyl. 1…. Cyl. 12 Feedback signals generated by inductive sensor on
1,2,3,4,5,6 Output, 24 VDC -> 48-96
lubricator. 4:Fb, 5:24 VDC, 6:0 VDC
Input, 24 VDC <-
BCU
Pick-up: Pickups supply BCU with TDC for backup running. 1:24 VDC, 2:0 VDC Pick-up
J30:1,2,3,5 46,47
3:TDC #1+, 5:TDC #2+ Output, 24 VDC supply ->
MCU Input, 24 VDC <-
1:TDC #1+, 3:TDC #2+
J22:1,3
MCU
Encoder: Shaft Encoder supplies MCU with TDC and trigger J20:1: TDC+, J20:3: TRIGG+ Encoder
J20:1,3, FJ7:1,2 44,45
pulses for calculation of lub. oil injection. FJ7: Supply Output, 24 VDC supply ->
Input, 24 VDC <-
MCU
HMI panel: Human machine interface for Operational and 3:IB+, 4:IB-, 5:GND HMI panel
J56:3,4,5 37-43
parametter setting of the ALCU. Output, 24 VDC supply ->
SBU Input, pot. Free <-

Terminalstrip X1, X2
FJ2: Selector Switch Interlink <->
FJ2:1,2,3, FJ4:1
FJ4: Supply
SBU
Starters: Pump station starters. Starters
P2:1,3, FJ5:1,2 35,36
Start / Stop of Pump 1 and 2. Output, 24 VDC ->
MCU
Telegraph pos.: Analog 4-20mA LCD signal from Governor. For Telegraph pos.
J40:1,3 33,34
Mechanical governors. Signal to be powered by ALCU. Input, Analog, 4-20mA <-
MCU
Thermal cut out Potential free contact to ALCU from Pump station
Thermal cut out #1, #2
#1, #2: starters. Contact close when motor protection relay J25:1,3 31,32
trips. Input, pot. Free <-
MCU
Oil Pressure: Analog signal from Pressure transmitter on pump Oil Pressure
J41:1 30
station. 4-20 mA=0-100 bar. Input, Analog, 4-20mA <-
MCU
Oil Temperature: Analog signal from Pt-100 temperature sensor on Oil Temperature
J43:1,2 28,29
pump station. 100 ohm at 20 C. Input, Analog, Pt-100 <-
MCU
Index: Analog 4-20 mA signal from index transmitter. Index
J42:1 27
Input, Analog, 4-20mA <-
MCU
Prelub: Potential free contact to ALCU, Prelub
J30:7,8 25,26
to close when prelubrication required. Input, pot. Free <-
MCU
Astern: Potential free contact to ALCU, Astern
J30:5,6 23,24
to be closed when engine in Astern. Input, pot. Free <-
MCU
MCU Stop: Potential free contact to ALCU, MCU Stop
J30:9,10 21,22
to be closed when engine in Stop. Input, pot. Free <-
Date Des. Chk. Appd. A.C. Change / Replacement
20020508 DFA JHV JHV * 0
Similar Drawing no.: Replacement for Ident no.:

Scale: Size: Type Page No.:


ALCU signal description MAN B&W Diesel A/S
1:1 A3 02 (03)
Info No. Description Ident. No.

This drawing is the property of MAN B&W Diesel A/S and is to be treated as confidential by the party to whom it has been submitted by 3 63 140 Control Unit. Cyl. Lub. 0789390-3
MAN B&W Diesel A/S and is not to be disclosed to any third party without the specific prior written permission of MAN B&W Diesel A/S Final User Info No. Final User Description Final User Ident. No.
BCU
BCU Stop: Potential free contact to ALCU, BCU Stop
FJ13:1, J5:3 19,20
to be closed when engine in Stop. Input, pot. Free <-
MCU
Slow down: Potential free contact from ALCU, Slow down
J31:5,6 17,18
closed when Slow down is generated. Output, pot. Free ->
BCU
J8:3,4
BCU
BCU fail: Potential free contact from ALCU, BCU fail
J10:1,2 15,16
open when BCU has alarm. Output, pot. Free ->
BCU
MCU fail: Potential free contact from ALCU, MCU fail
J8:1,2 13,14
open when MCU fails. Output, pot. Free ->
BCU
BCU Power fail: Potential free contact from ALCU, BCU power fail
FJ3:1,2 9,10,11,12

Terminalstrip X1, X2
open when BCU loses 24 VDC supply. Output, pot. Free ->
SBU
FJ36:1,2
SBU
BCU In CTRL: Mode indication, potential free contact from ALCU, BCU In CTRL
FJ28:1,2 7,8
closed when BCU in Control. Output, pot. Free ->
MCU
MCU Power fail: Potential free contact from ALCU, MCU Power fail
FJ3:1,2 3,4,5,6
open when MCU loses 24 VDC supply. Output, pot. Free ->
SBU
FJ38:1,2
MCU
Com. Alarm: Potential free contact from ALCU, Com. Alarm
J32:1,2 1,2
open when common alarm is generated. Output, pot. Free ->
MCU
Modbus: Optional RS-232 communication link from ALCU. 2:RxD, 4:TxD, 5:GND Modbus
J55:2,4,5 TxD, RxD
RS-232 <->
(optional)
BCU
Power B: Supply power B to ALCU, Supplies BCU and SBU in 1: 24 VDC, 2: 0 VDC Power B
FJ1:1,2 L+,L-
BCU mode. 24 VDC supply <-
MCU
Power A: Supply power A to ALCU, Supplies MCU and SBU in 1: 24 VDC, 2: 0 VDC Power A
FJ1:1,2 L+,L-
MCU mode. 24 VDC supply <-

Date Des. Chk. Appd. A.C. Change / Replacement


20020508 DFA JHV JHV * 0
Similar Drawing no.: Replacement for Ident no.:

Scale: Size: Type Page No.:


ALCU signal description MAN B&W Diesel A/S
1:1 A3 03 (03)
Info No. Description Ident. No.

This drawing is the property of MAN B&W Diesel A/S and is to be treated as confidential by the party to whom it has been submitted by 3 63 140 Control Unit. Cyl. Lub. 0789390-3
MAN B&W Diesel A/S and is not to be disclosed to any third party without the specific prior written permission of MAN B&W Diesel A/S Final User Info No. Final User Description Final User Ident. No.

You might also like