Service Letter

Date : March 3, 2015


Ref. No. : HHI-MAN-SL-15-001

Wrong cable connection between CCU and TSA for G/S50ME-B9.3

Dear Sirs,

Recently we have been experienced from one engine in-service that wrong connection was found
between TSA and only CCU1 with enclosure type of CCU cabinet on G/S50ME-B9.3.

Enclosure type of CCU cabinet

For enclosure CCU cabinet, the each TSA A&B is connected to each CCU1 and CCU2 in order
to avoid the shutdown when one of the CCUs is failure.

1/2
Wiring for enclosure CCU cabinet Reconnection of the Cable from TSA-A & B

In this regard, we would like to ask you to connect the cable from TSA-B to CCU2 for the
noted engines as enclosed. If new cable is necessary, we will supply the cable free of charge.

※Appendix: The list of the concerned engines

We hope that the above would be of service to you.

Faithfully yours,

James Lee, General Manager

Engine & Machinery Global Service Dep't


Engine & Machinery Division
Tel. : +82 52 203 6168, Fax.+82 52 202 7581
24/7 Hot line : +1 212 845 9803
E-mail : globalservice@hhi.co.kr