Alpha lubricator HMI panel menu structure - part 4, setup menu

MCU SW 2.5
n [rpm] PASS
(engine speed) password =
"[▼] [▲] [esc] [enter]"
MEP [%]
(mean efficient
pressure)
In.AdJ
pOil [bar] (index transmitter
(norm. 40-50 bar) adjustment menu)
XXX
(alarm 35 bar) press "▼ ▲" to change
press "ENTER" to SAVE
toil [°C]
(norm 40-60 °C)
(alarm 70 °C)
ti.Adj inJ.oF [°]
r XXX (injection timing adjustment (injection offset, common
(total stroke/min) menu) angle offset for all cylinders)

hY.dEL [ms]
Lcd X (hydraulic delay, common
(LCD status) time offset for all cylinders)

(0=0ff, 1=on)
ALR XX
(active alarms)
(see alarm list) LCd P.6 XXX
LAL XX (load change dependent (telegraph signal scale) press "▼ ▲" to change
(logged alarms) lubrication adj. menu) (0-200 %) press "ENTER" to SAVE
clear = [ENTER]
P.5
F.rAtE (LCD factor)
(feed rate adj.) (norm 125 %)

P.4 Menu navigation


diSP InJ.AL (holding time) press "▼ ▲" to select
(display menu) (injection amount algorithm (norm 30 min.) press "ENTER" to SAVE
menu)(norm. Po) P.3
Connt (average time)
(connection test (norm 10 sec.)
menu) P.2 tELE.P
SEtuP FE.Adj (deviation %) (telegraph position, analog
(setup menu) (feed rate regulation (norm. 10 %) signal from governor)
(MBD Service) parameter adjustment)
P.1 E.Sig
n.PrL (LCD mode) (external signal, LCD start
(number of pre- (norm. E.FL) controlled externally)
lubrications)
E.FL
r.run (external flag, start and
(rpm run adjustment) duration controlled ext.)

Menu navigation int.


Ang.dE press "▼ ▲" to select (internal, LCD controlled
(angle deviation limit bet. press "ENTER" to SAVE internally)
MCU and BCU tacho)
on
Pu (permanent on)
(booster pump mode
adjustment)
Po. oFF
Lubr. (power proportional feed rate (permanent off)
(booster pump mode calculation)
adjustment)
rPnn
Str.hI (rpm proportional feed rate
(total lubricator stroke calculation)
counter adjustment)
nnep
Str.Lo (MEP, mean efficient
(total lubricator stroke pressure prop. feed rate
counter adjustment, ) calc.)

Pnncr
(Total engine power in KW)

Par
('raw' adjustment out of all
setup parameters)

flow chart 4