This technical document provides performance specifications for ESM160-ESM200 60Hz fixed speed, air cooled compressors. It includes data on maximum and minimum working pressures, ambient temperature range, flow rates and power requirements at varying pressures, electrical specifications like voltage and current draw, cooling information like ventilating capacities and temperatures, and dimensions. The compressors come in CE compliant versions with IP55 rated motors and meet IE-3 and ECA qualifying standards for energy efficiency.
This technical document provides performance specifications for ESM160-ESM200 60Hz fixed speed, air cooled compressors. It includes data on maximum and minimum working pressures, ambient temperature range, flow rates and power requirements at varying pressures, electrical specifications like voltage and current draw, cooling information like ventilating capacities and temperatures, and dimensions. The compressors come in CE compliant versions with IP55 rated motors and meet IE-3 and ECA qualifying standards for energy efficiency.
This technical document provides performance specifications for ESM160-ESM200 60Hz fixed speed, air cooled compressors. It includes data on maximum and minimum working pressures, ambient temperature range, flow rates and power requirements at varying pressures, electrical specifications like voltage and current draw, cooling information like ventilating capacities and temperatures, and dimensions. The compressors come in CE compliant versions with IP55 rated motors and meet IE-3 and ECA qualifying standards for energy efficiency.
Performance Data ESM160-7.5 A ESM160-9 A ESM160-13 A ESM200-7.5 A ESM200-9 A ESM200-13 A Maximum working pressure bar g 7.5 9 13 7.5 9 13 Minimum working pressure bar g 5,0 Ambient temperature - min/max °C 1 to 45
FAD* m3/min 32,11 29,81 24,52 38,13 36,25 29,85
5 bar Total input power* (P spec. - kW min/m³) kW 174,44 (5,43) 159,53 (5,35) 127,69 (5,21) 213,21 (5,59) 200,76 (5,54) 159,14 (5,33) 3 FAD* m /min 32,06 29,76 24,43 38,04 36,18 29,80 6 bar Total input power* kW 184,88 (5,77) 169,50 (5,70) 136,10 (5,57) 224,81 (5,91) 211,99 (5,86) 169,08 (5,67) FAD* m3/min 32,00 29,69 24,33 37,94 36,09 29,73 7 bar Total input power* kW 195,50 (6,11) 179,60 (6,05) 144,61 (5,94) 236,75 (6,24) 223,52 (6,19) 179,15 (6,03) FAD* m3/min 31,96 29,64 24,27 37,89 36,05 29,68 7.5 bar Total input power* kW 200,93 (6,29) 184,74 (6,23) 148,93 (6,14) 242,93 (6,41) 229,46 (6,37) 184,27 (6,21) FAD* m3/min 29,59 24,20 35,99 29,63 8 bar Total input power* kW 189,96 (6,42) 153,31 (6,33) 235,56 (6,54) 189,47 (6,40) FAD* m3/min 29,45 24,05 35,87 29,49 9 bar Total input power* kW 200,55 (6,81) 162,21 (6,74) 248,13 (6,92) 200,03 (6,78) FAD* m3/min 23,87 29,31 10 bar Total input power* kW 171,15 (7,17) 210,62 (7,19) FAD* m3/min 23,67 29,10 11 bar Total input power* kW 179,99 (7,60) 221,06 (7,60) FAD* m3/min 23,44 28,86 12 bar Total input power* kW 188,74 (8,05) 231,35 (8,02) FAD* m3/min 23,20 28,60 13 bar Total input power* kW 197,45 (8,51) 241,60 (8,45) Total input power at no load, fan switched off kW 52,2 48,1 38,6 63,0 59,7 48,1 Male rotor speed rpm 2006 1856 1514 2393 2272 1858 Approx. discharge temperature of air above ambient °C 8 7 7 8 7 7 Free field noise level ** dB(A) 78 79 Electrical Data Nominal motor rating kW 160 200 Nominal voltage [tolerance] (Frequency) 380V[±10%] / 460V[±10%] (60 Hz) Full load current max. at 380V / 460V A 360 / 320 474 / 397 Starting current (max. % of full load current) % 220 / 213 319 / 317 Standard drive motor detail IP55 (IE-3) - IEC 60034-2-1 ECA Qualifying Drive motor speed rpm 3600 Fan motor rating (Air / Oil - cooler) kW 1,5 / 3,0 (IE-3) 2,2 / 3,0 (IE-3) Suggested cable size at 380V / 460V *** mm2 2x 3x 95 PE 95 / 2x 3x 70 PE 70 2x x3 150 PE 150 / 2x x3 95 PE 95 Suggested fuse rating at 380V / 460V ( type gG ) A 2x 3x 224 / 2x 3x 200 2x 3x 315 / 2x 3x 250 Cooling Data Machine Ventilating capacity max. m³/min 20 30 Ventilating fan capacity max (Air / Oil - cooler) m3/min 100 / 220 100 / 220 Heat rejected by ventilating fan (max. % of actual input power) % 95 Size of cooling air inlet aperture mm 1700 x 1520 Size of cooling air outlet aperture mm 1790 x 420 Approx. cooling air temp. above ambient (at max. power) °C 18 22 Max. allowable pressure drop in duct (at ambient 35°C / 45°C) Pa 90 / 40 70 / 20 Weights, Dimensions and Capacities Data Compressor oil capacity l 120 Oil carry over mg/m3 <3 Compr. air delivery connection (male screwed thread) Flansch EN 1092-1 / 13 / DN 80 / PN 16 / P250GH Weight kg 4186 4415 Package dimensions L x W x H mm 2907 x 2071 x 2193 * Data measured and stated in accordance with ISO1217 4rd Edition Annex C and at the following conditions: Air Intake Pressure: 1 bar a / 14.5 psia Air Intake Temperature: 20°C / 68°F Humidity: 0% (dry) ** Measured in free field conditions in accordance with the ISO 2151, tolerance ± 3dB(A). GD policy is one of continuous improvement and we therefore reserve the right to alter specifications without prior notice. *** max.30°C / max. 50m / Copper