Performance Data L200 RS - 13 A


Maximum working pressure bar g 13.0
Minimum working pressure bar g 5.0
Ambient temperature - min/max °C 1 to 45
min. speed speed 1 speed 2 speed 3 speed 4 max. speed
FAD* (Male rotor speed - rpm) 3
m /min 7.13 (500) 13.59 (874) 20.05 (1252) 26.51 (1636) 32.97 (2025) 39.44 (2419)
5 bar
Total input power* (P spec. - kW min/m³) kW 41.99 (5.89) 70.48 (5.19) 101.38 (5.06) 135.89 (5.13) 174.20 (5.28) 215.32 (5.46)
FAD* 3
m /min 6.88 (500) 13.36 (876) 19.83 (1255) 26.31 (1639) 32.79 (2027) 39.27 (2419)
6 bar
Total input power* kW 45.91 (6.68) 76.41 (5.72) 109.35 (5.51) 145.96 (5.55) 186.38 (5.68) 229.58 (5.85)
FAD* 3
m /min 6.64 (500) 13.14 (877) 19.63 (1256) 26.13 (1640) 32.63 (2028) 39.12 (2419)
7 bar
Total input power* kW 49.85 (7.50) 82.25 (6.26) 117.19 (5.97) 155.92 (5.97) 198.59 (6.09) 244.11 (6.24)
FAD* m3/min 6.54 (500) 13.04 (877) 19.55 (1256) 26.05 (1640) 32.55 (2028) 39.05 (2419)
7.5 bar
Total input power* kW 51.82 (7.92) 85.10 (6.53) 121.00 (6.19) 160.81 (6.17) 204.68 (6.29) 251.49 (6.44)
FAD* m3/min 6.44 (500) 12.80 (867) 19.16 (1238) 25.52 (1612) 31.87 (1991) 38.23 (2373)
8 bar
Total input power* kW 53.79 (8.35) 87.08 (6.80) 122.91 (6.42) 162.61 (6.37) 206.36 (6.47) 253.23 (6.62)
FAD* m3/min 6.29 (500) 12.35 (848) 18.42 (1199) 24.48 (1555) 30.55 (1916) 36.61 (2281)
9 bar
Total input power* kW 57.76 (9.19) 90.75 (7.35) 126.24 (6.85) 165.58 (6.76) 209.09 (6.85) 256.20 (7.00)
FAD* m3/min 6.17 (500) 11.94 (828) 17.71 (1161) 23.48 (1498) 29.25 (1841) 35.03 (2189)
10 bar
Total input power* kW 61.74 (10.01) 94.11 (7.88) 128.98 (7.28) 167.85 (7.15) 211.13 (7.22) 258.59 (7.38)
FAD* m3/min 6.08 (500) 11.54 (808) 16.99 (1120) 22.45 (1438) 27.90 (1761) 33.36 (2090)
11 bar
Total input power* kW 65.74 (10.81) 97.05 (8.41) 130.91 (7.70) 168.93 (7.53) 211.67 (7.59) 259.18 (7.77)
FAD* m3/min 6.03 (500) 11.16 (788) 16.30 (1081) 21.44 (1378) 26.57 (1682) 31.71 (1991)
12 bar
Total input power* kW 69.76 (11.58) 99.79 (8.94) 132.38 (8.12) 169.26 (7.90) 211.14 (7.95) 258.27 (8.14)
FAD* m3/min 5.99 (500) 10.81 (769) 15.63 (1042) 20.44 (1319) 25.26 (1603) 30.08 (1892)
13 bar
Total input power* kW 73.79 (12.33) 102.38 (9.47) 133.49 (8.54) 168.88 (8.26) 209.43 (8.29) 255.49 (8.49)

Total input power at no load, fan switched off kW 15.4


Male rotor speed rpm 500 to 2419
Approx. discharge temperature of air above ambient (at max. power) °C 8
Free field noise level ** at 70% load / at 100% load dB(A) 77 / 79 (50Hz)
Electrical Data
Nominal motor rating kW 200
Nominal voltage [tolerance] (Frequency) 400V[±10%] / 50Hz
Full load current max. at 400V A 445
Starting current (max. % of full load current ) % 100
Standard drive motor detail IP55 (IE-3) - IEC 60034-2-1 ECA Qualifying
Drive motor speed min./max. rpm 500 to 2419
Fan motor rating (Air / Oil - cooler) kW 2,2 / 5,5 (IE-3)
Suggested cable size at 400V (max.30°C / max. 50m / Copper) mm2 2x3x 95 PE 95
Suggested fuse rating at 400V ( type gS ) A 2x3x 250
Cooling Data
Ventilating fan capacity max (Air / Oil - cooler) m3/min 100 / 240
Heat rejected by ventilating fan (max. % of actual input power) % 95
Size of cooling air inlet aperture mm 1700 x 1520
Size of cooling air outlet aperture mm 1790 x 420
Approx. cooling air temperature above ambient (at max. power) °C 22
Max. allowable pressure drop in duct at ambient 35°C / 45°C Pa 110 / 60
Weights, Dimensions and Capacities Data
Compressor oil capacity l 120
Oil carry over mg/m3 <3
Compressed air delivery connection (female screwed thread) Flansch EN 1092-1 / 13 / DN 80 / PN 16 / P250GH
Weight kg 4573
Package dimensions L x W x H mm 2949 x 2111 x 2193
* Data measured and stated in accordance with ISO1217 4rd Edition Annex C & E and at the following conditions:
Air Intake Pressure: 1 bar a / 14.5 psia
Air Intake Temperature: 20°C / 68°F
Humidity: 0% (dry)
** Measured in free field conditions in accordance with the ISO 2151, tolerance ± 3dB(A).