You are on page 1of 15

STARTING TIME CALCULATION ( DIRECT ON LINE )

Equp.: CENTRIFUGAL FAN Load GD² =


340
Motor kW 250
Load GD² referred to motor shaft (kgm²) 340.0 Load GD² * ( load RPM ² / Motor RPM² )
LOAD RPM 2970 From load T-N curve
Load Average Torque(kgm) 10.71 From load T-N curve
Motor GD² ( kgm²) 25.7
Load Full load torque(kgm) 81.99 From load T-N curve LOAD KG-M * FACTOR
Motor RPM 2970
Motor FLT ( kgm ) 81.99 974 * motor kW / motor RPM
Motor starting torque ( %FLT) 160
Motor pullup torque ( %FLT) 130
Motor pullout torque ( %FLT) 225
Motor average torque ( kgm ) 126.05 Motor flt * (stg+put+pot+100)/400

Voltage available at motor terminals at 100% V at 80% V at 110% V


( k = factor for % Rated Voltage ) 1 0.80 1.10
Motor average torque
= Motor flt * (stg+put+pot+100)/400*k 126.05 80.67 152.53
Load Average torque 10.71
( taken from curve ) ( kgm )

Starting time on DOL (second ) = ( load GD² + motor GD² ) * motor RPM
375 ( Motor average torque - load average torque )

= 25.11

NADZD510_2_01 75%V 110%V


Thermal Withstand Time ( second ) 39 69 27
Load Curve points
0 0
10 3
20 3
30 6
40 12
50 22
60 33
70 46
80 62
90 84
100 96
AV LOAD TORQUE (KGM) 0.3336363636
do not touch values in red

6256 15.00
761 4.00
775 4.00
798 8.00
829 16.00
870 26.00
920 40.00
979 54.00
1047 69.00
1124 85.00
1210 100.00
1415.36363636 lbf inch 421.00
16.3410165289 kg-m 38.27
STARTING TIME CALCULATION ( STAR - DELTA )
Equp. AIR FAN Load GD² =
Curve Number : 1060
Motor kW 90
Load GD² referred to motor shaft (kgm²) 1060 Load GD² * ( load RPM ² / Motor RPM² )
Load RPM 980 From load T-N curve
Load Average Torque(kgm) 53.24 From load T-N curve
Motor GD² ( kgm²) 17
Load Full load torque(kgm) 79.00 From load T-N curve
Motor RPM 980
Motor FLT ( kgm ) 89.45 974 * motor kW / motor RPM
Motor starting torque ( %FLT) 200
Motor pullup torque ( %FLT) 150
Motor pullout torque ( %FLT) 250
Motor average torque ( kgm ) ( DOL ) 156.54 Motor flt * (stg+put+pot+100)/400

Changeover from ' Star ' to ' Delta ' at 80% motor speed
Before changeover : ( From 0% speed to 80% speed )
Voltage available at motor terminals at 100% V at 80% V at 110% v
( k = factor for % of Rated Voltage ) 1 0.80 1.10
Motor average torque during star
=0.01*(sgt+put+pot) / 9 * motor FLT* k ² 59.63 38.16 72.16
Load Average torque upto 80% speed 14.77
( taken from curve ) ( kgm )
Starting time in star(second ) = (Load GD²+Motor GD²) * motor RPM * 0.9
I.e. upto 80% speed 375 ( Motor avg.torque - load avg. torque)

= 56.47 108.29 44.14

After changeover from star to delta ( From 80% to 100% speed)


Voltage Available at motor terminals at 100% V at 80% V at 110% v
k = factor for % Rated Voltage 1 0.80 1.10
Motor average torque in delta
= 0.01*(pot + flt ) / 2 * motor FLT* k ² 156.54 100.18 189.41
Load Average torque after changeover 63.73
( taken from curve ) ( kgm)
Starting time in delta(second ) = (Load GD²+Motor GD²) * motor RPM * 0.1
375 ( Motor avg.torque - load avg. torque)
Starting time in delta (second ) = 3.03 7.72 2.24
Starting time in star (80%SPEED) = 56.47 108.29 44.14
Starting time in delta (second ) = 3.03 7.72 2.24
Total starting Time ( second ) 59.5 116.0 46.4
Thermal Withstand Time ( second ) 60.0 94 50
Comment: Motor suitable for the specified application

CUSTOMER :ISGEC
Load Curve points
0 0
10 3
20 3
30 6
40 12
50 22
60 33
70 46
80 62
90 84
100 96
AV LOAD TORQUE (KGM) 0.3336363636
THESE ARE CALCULATED
Load Curve points
0 0
10 3
20 3
30 6
40 12
50 25
60 36
70 50
80 65
90 84
100 96
AVE TORQ 0.35
Crompton Greaves Ltd.
LT Motors Division
Maximum permissible load gd2 values

KW Pole Frame Full load Starting Motor Maximum Starting


speed Torque GD2 kg- load gd2 time
RPM % FLT m 2
kg-m 2
-seconds

7.5 2 ND160M 2910 225 0.13 4.4 8.5


4 ND160M 1460 225 0.31 17 8.5
6 ND160M 975 200 0.46 35 8.5
8 ND160L 710 150 0.64 53 8.5
9.3 2 ND160M 2920 250 0.13 5.9 8.5
4 ND160M 1460 175 0.31 17 8.5
6 ND160L 975 200 0.59 44 8.5
8 ND180M 720 175 0.99 70 8.5
11 2 ND160M 2920 250 0.13 7 8.5
4 ND160M 1460 200 0.36 23 8.5
6 ND160L 975 200 0.64 52 8.5
8 ND180L 720 175 1.16 83 8.5
15 2 ND160M 2920 250 0.17 9.6 8.5
4 ND160L 1460 200 0.47 31 8.5
6 ND180L 975 225 1.16 80 8.5
8 ND200L 725 225 2.14 180 10.5
18.5 2 ND160L 2920 275 0.21 13.1 8.5
4 ND180M 1475 200 0.81 38 8.5
6 ND200L 975 200 1.69 108 10.5
8 ND225S 725 175 3.24 171 10.5
22 2 ND180M 2920 275 0.44 15 8.5
4 ND180L 1475 200 0.95 45 8.5
6 ND200L 975 200 2.04 129 10.5
8 ND225M 725 175 3.61 203 10.5
30 2 ND200L 2950 200 0.80 18.7 10.5
4 ND200L 1475 250 1.62 86 10.5
6 ND225M 980 200 3.61 173 10.5
8 ND250M 735 175 4.82 270 10.5
37 2 ND200L 2950 200 0.89 23.3 10.5
4 ND225S 1480 250 2.64 113 10.5
6 ND250M 980 250 4.82 259 10.5
8 ND280S 735 200 8.01 472 13
45 2 ND225M 2955 225 1.87 30 10.5
Maximum permissible load gd2 values
4 ND225M 1480 250 3.13 138 10.5
6 ND280S 980 250 8.01 390 13
8 ND280M 725 175 9.89 515 13
55 2 ND250M 2955 175 2.79 28.4 10.5
4 ND250M 1475 200 3.45 139 10.5
6 ND280M 980 175 9.89 341 13
8 ND315S 740 250 14.12 840 13
75 2 ND280S 2975 225 7.14 59.9 13
4 ND280S 1480 250 7.21 284 13
6 ND315S 987 250 14.12 640 13
8 ND315M 740 200 18.98 942 13
90 2 ND280M 2975 225 8.18 72 13
4 ND280M 1480 250 8.26 341 13
6 ND315M 987 250 17.00 768 13
8 ND315L 740 250 29.85 1368 13
110 2 ND315S 2965 200 6.63 81 13
4 ND315S 1488 225 11.62 381 13
6 ND315M 987 250 18.98 941 13
8 ND315L 740 250 29.85 1678 13
132 2 ND315M 2965 200 7.97 97 13
4 ND315M 1488 225 13.98 457 13
6 ND315L 985 250 29.85 1167 13
8 ND315L 740 225 29.85 1877 13
150 2 ND315L 2975 175 16.37 87.5 13
4 ND315M 1488 225 15.61 520 13
6 ND315L 990 250 29.85 1271 13
8 ND355L 740 150 33.16 1402 13
160 2 ND315L 2975 175 16.37 94 13
4 ND315L 1490 200 24.97 481 13
6 ND315L 990 250 29.85 1358 13
8 ND355L 740 175 36.73 1754 13
180 2 ND315L 2975 200 16.37 74 13
4 ND315L 1490 225 24.97 616 13
6 ND355L 990 225 33.16 1365 13
8 ND355LX 745 135 61.40 1404 13
200 2 ND315L 2975 200 16.37 142 13
4 ND315L 1490 225 24.97 661 13
6 ND355LX 991 150 55.26 1012 13
8 ND355LX 745 135 61.40 1593 13
Maximum permissible load gd2 values
225 2 ND355L 2980 175 25.70 129 13
4 ND355L 1490 185 35.57 597 13
6 ND355LX 991 150 61.40 1139 13
8 ND355LX 745 135 61.40 1846 13
250 2 ND355LX 2980 175 25.70 146 13
4 ND355L 1490 185 35.57 668 13
6 ND355LX 993 150 61.40 1267 13
315 2 ND355LX 2980 200 30.70 218 13
4 ND355LX 1492 175 39.52 828 13
300 6 ND355LX 993 150 61.4 2410 19.1 TH=45

NOTE: Permissible maximum load gd square values are given above considering one hot start
& 2 consecutive cold starts.
Driven equipment is considered as fan.
Absorbed power by driven equipment at full load is 15% less than motor full load kw.
load gd square value is in kg-m sq referred at load rpm.

Prepared By: Smita S. Nisal


Date: 1.9.2003
STARTING TIME CALCULATION primary
Equp.: CENTRIFUGAL FAN Load GD² =
1980
Motor kW 55
Load GD² referred to motor shaft (kgm²) 1980.0 Load GD² * ( load RPM ² / Motor RPM² )
LOAD RPM 1475 From load T-N curve
Load Average Torque(kgm) 12.12 From load T-N curve
Motor GD² ( kgm²) 11.62
Load Full load torque(kgm) 36.32 From load T-N curve LOAD KG-M * FACTOR
Motor RPM 1475
Motor FLT ( kgm ) 36.32 974 * motor kW / motor RPM
Motor starting torque ( %FLT) 200
Motor pullup torque ( %FLT) 175
Motor pullout torque ( %FLT) 250
Motor average torque ( kgm ) 65.83 Motor flt * (stg+put+pot+100)/400

Voltage available at motor terminals at 100% V at 80% V at 110% V


( k = factor for % Rated Voltage ) 1 0.80 1.10
Motor average torque
= Motor flt * (stg+put+pot+100)/400*k 65.83 42.13 79.65
Load Average torque 12.12
( taken from curve ) ( kgm )

Starting time on DOL (second ) = ( load GD² + motor GD² ) * motor RPM
375 ( Motor average torque - load average torque )

= 145.9 261.0 116.0

75%V 110%V
Thermal Withstand Time ( second ) 25 14 30
Load Curve points
0 0
10 3
20 3
30 6
40 12
50 22
60 33
70 46
80 62
90 84
100 96
AV LOAD TORQUE (KGM) 0.3336363636
wr2
131 lb-ft2
5.531 kg-m2

do not touch values in red

70.9090909091

45.0378333333
112
14.625
14.62*2.5 360.00
63.5*10 42.66
50 1.23
51.5 1.00

169.2
112.8
170
STARTING TIME CALCULATION primary
Equp.: CENTRIFUGAL FAN Load GD² =
1980
Motor kW 55
Load GD² referred to motor shaft (kgm²) 1980.0 Load GD² * ( load RPM ² / Motor RPM² )
LOAD RPM 1475 From load T-N curve
Load Average Torque(kgm) 58.11 From load T-N curve
Motor GD² ( kgm²) 3.45
Load Full load torque(kgm) 36.32 From load T-N curve LOAD KG-M * FACTOR
Motor RPM 1475
Motor FLT ( kgm ) 36.32 974 * motor kW / motor RPM
fluid coupling setting torque 160
200
Motor pullout torque ( %FLT) 300
Motor average torque ( kgm ) 108.96 Motor flt * (stg+put+pot+100)/400

Voltage available at motor terminals at 100% V at 80% V at 110% V


( k = factor for % Rated Voltage ) 1 0.80 1.10
Motor average torque
= Motor flt * (stg+put+pot+100)/400*k 108.96 69.73 131.84
Load Average torque 58.11
( taken from curve ) ( kgm )

Starting time on DOL (second ) = ( load GD² + motor GD² ) * motor RPM
375 ( Motor average torque - load average torque )

= 153.4 671.3 105.8

75%V 110%V
Thermal Withstand Time ( second ) 160 90 194
thermal withstand time shall be at 160% FLC
Load Curve points
0 0
10 3
20 3
30 6
40 12
50 22
60 33
70 46
80 62
90 84
100 96
AV LOAD TORQUE (KGM) 0.3336363636
wr2
131 lb-ft2
5.531 kg-m2

do not touch values in red

70.9090909091

45.0378333333
112
14.625
14.62*2.5 360.00
63.5*10 42.66
50 1.23
51.5 1.00

169.2
112.8
170

You might also like