D110-10RS TIS D110RS/10/CE

Technical Information Sheet V2

50 Hz, Variable Speed, Air Cooled, CE Version 30.09.2014

Performance Data D110-10RS


Maximum working pressure bar g 10.0
Minimum working pressure bar g 4.0
Ambient temperature min/max °C 2 / 40

min. 1 2 3 4 max.
FAD* (Male rotor speed - rpm) m3/min 10.90 (8000) 12.25 (8765) 13.61 (9552) 14.97 (10365) 16.32 (11205) 17.68 (12014)
4bar
Total input power* (P spec. - kW min/m³) kW 64.12 (5.88) 70.22 (5.73) 76.51 (5.62) 83.03 (5.55) 89.82 (5.50) 96.93 (5.48)
FAD* m3/min 10.83 (8000) 12.19 (8769) 13.55 (9559) 14.91 (10372) 16.27 (11210) 17.63 (12014)
5 bar
Total input power* kW 69.35 (6.40) 76.03 (6.24) 82.88 (6.12) 89.94 (6.03) 97.24 (5.98) 104.84 (5.95)
FAD* m3/min 10.77 (8000) 12.13 (8773) 13.49 (9565) 14.85 (10379) 16.21 (11215) 17.58 (12014)
6 bar
Total input power* kW 73.99 (6.87) 81.19 (6.69) 88.55 (6.56) 96.09 (6.47) 103.85 (6.40) 111.87 (6.36)
FAD* m3/min 10.70 (8000) 12.07 (8777) 13.43 (9572) 14.80 (10385) 16.16 (11219) 17.52 (12014)
7 bar
Total input power* kW 78.30 (7.32) 85.97 (7.12) 93.78 (6.98) 101.75 (6.88) 109.92 (6.80) 118.34 (6.75)
FAD* m3/min 10.67 (8000) 12.04 (8779) 13.40 (9575) 14.77 (10389) 16.13 (11222) 17.50 (12014)
7,5 bar
Total input power* kW 80.44 (7.54) 88.33 (7.34) 96.35 (7.19) 104.54 (7.08) 112.92 (7.00) 121.54 (6.95)
FAD* m3/min 10.64 (8000) 12.01 (8781) 13.37 (9578) 14.74 (10392) 16.10 (11224) 17.47 (12014)
8 bar
Total input power* kW 82.41 (7.74) 90.45 (7.53) 98.63 (7.38) 106.98 (7.26) 115.54 (7.17) 124.35 (7.12)
FAD* m3/min 10.58 (8000) 11.95 (8785) 13.31 (9584) 14.68 (10398) 16.05 (11229) 17.42 (12014)
9 bar
Total input power* kW 86.79 (8.21) 95.25 (7.97) 103.83 (7.80) 112.60 (7.67) 121.57 (7.57) 130.79 (7.51)
FAD* m3/min 10.51 (8000) 11.88 (8789) 13.25 (9591) 14.63 (10405) 16.00 (11233) 17.37 (12014)
10 bar
Total input power* kW 91.01 (8.66) 99.69 (8.39) 108.53 (8.19) 117.60 (8.04) 126.94 (7.94) 136.59 (7.87)

Total input power at no load, 1 fan switched off kW 20.0


Male rotor speed 1st stage rpm 8000 to 12014
Male rotor speed 2nd stage rpm 11200 to 16819

Approx. discharge temperature of air above ambient (at max. power) °C 6.0

Free field noise level ** at 70% load / at 100% load dB(A) 76 / 78


Electrical Data
Nominal motor rating kW 110
Nominal voltage [tolerance] (Frequency) 380V[+10% -5%]; 400V[±10%]; (50Hz)
Full load current max. at 380V / 400V A 231 / 220
Starting current (max. % of full load current ) % 100

Standard drive motor detail IP55 (IE-3) - IEC 60034-2-1 ECA Qualifying

Drive motor speed min./max. rpm 2417 / 3630


Fan motor rating kW 2 x 3,2 (IP-54)
Oil pump motor rating kW 0,55 (IP-54)
Water pump motor rating KW 0,75 (IP-54)

Suggested cable size at 380V / 400V *** mm2 3 x 95 PE50 / 3 x 95 PE50

Suggested fuse rating at 380V / 400V ( type gG ) A 3 x 300 / 3 x 300


Cooling Data
Ventilating fan capacity m3/min 338
Heat rejected by ventilating fan (max. % of actual input power) % 95
Size of cooling air inlet aperture mm 1210 x 975
Size of cooling air outlet aperture mm 1578 x 1390

Approx. cooling air temperature above ambient (at max. power) °C 22

Max. allowable pressure drop in duct at ambient 35°C / 45°C Pa 120 / 85

Weights, Dimensions and Capacities Data


Compressor water capacity (water / gycol mixture) l 30
Compressor oil capacity l 24
Compressed air delivery connection Flange EN 1092-1 / 13 / B1 / DN80x8 / PN16
Condensate drains 5 x G1/2"
Weight kg 3278
Package dimensions L x W x H mm 2597 x 1744 x 2001
* Data measured and stated in accordance with ISO1217 4rd Edition Annex C & E and at the following conditions:
Air Intake Pressure: 1 bar a / 14.5 psia
Air Intake Temperature: 20°C / 68°F
Humidity: 0% (dry)
** Measured in free field conditions in accordance with the ISO 2151, tolerance ± 3dB(A).
*** max. 30°C / max. 50m / Copper
Gardner Denver policy is one of continuous improvement and we therefore reserve the right to alter specifications without prior notice.