A.

STRUCTURAL STEEL
S1. ALL CONTACT SURFACES OF STRUCTURAL STEEL SHALL
BE WELDED WITH 6mm THICK FILLET WELD U.O.S.
S2. ALL BUTT WELDS SHALL BE PROVIDED WITH A SEALING RUN.
S3. ALL INCLINED MEMBERS AND GUSSET PLATES ARE TO
BE CHECKED BY FULL SHOP LAYOUT.
S4. ALL PERMANENT HOLES SHALL BE

S5. ALL NUTS & BOLTS SHALL BE HIGH TENSILE GRADE 8.8
S6. ALL HOT ROLLED STEEL TUBE SHALL BE OF FY250 GRADE
UNLESS NOTED OTHERWISE SEPARATELY.
S7. ALL HOT ROLLED STANDARD STEEL SECTION
S8. ALL TUBES WHICH THICKNESS ARE LESS THAN 6mm WILL
BE WELDED WITH 4mm WELD U.N.O.
S9. ALL ANCHOR BOLTS SHALL BE GRADE OF 8.8.
S10. ALL BUILT UP SECTIONS (I & TUBE) SHALL BE OF GRADE=250Mpa
S11. USE GRADE OF CONCRETE M-30 UNLESS NOTED OTHERWISE.
S12. ALL HOLLOW TUBES TO BE CAPPED AT OPEN ENDS WITH
6mm THK. CAP PLATE.
S13. ALL WELDS SHALL CONFORM TO IS :816-1969.
S14. WELDING SHALL BE AS PER APPROVED PROCEDURE BY A
QUALIFIED WELDER. ALL THE WELDING SHALL BE SHOP WELD.
NO WELD IS PERMITTED AT SITE.
S15. BEFORE ACCEPTING THE FABRICATION MATERIAL, IT SHOULD BE
INSPECTED AND ENSURED THAT THE STEEL MATERIAL USED IS
OF TESTED QUALITY AND IS FREE FROM CRACKS AND ANY
OTHER INHERENT DEFECTS.
S16. ALL MEMBERS MEETING AT JOINT ARE FILLET WELDED EXCEPT
OTHERWISE STATED.
S17. ERECTION BOLT AND NUTS SHALL CONFIRM WITH
IS: 1363-1967 & IS: 1367-1967.
S18. ALL HOLES NECESSARY FOR FRICTION BOLTS SHALL BE
PLUGGED FULLY AFTER SUCCESSFUL COMPLETION OF
ERECTION WORK.
S19. FABRICATION DRAWING SHOULD BE PREPARED AND GOT
APPROVED FROM DDC AND DMRC BEFORE CONSTRUCTION.
S20. ALL DIMENSIONS TO BE CONFIRMED AT SITE BEFORE CUTTING
THE MEMBERS.
S21. FOR BOLTING MINIMUM EGDE DISTANCE SHALL BE 1.75d WHERE
D IS THE DIAMETER OF HOLE.
S22. MINIMUM C/C DISTANCE OF BOLT SHALL BE 2.5D WHERE D IS
THE DIAMETER OF BOLT.
S23. 100% TEST ON WELDING
S24. BOLTS FOR PURLIN SHALL BE OF 4.6 GRADE AS PER IS:1367-1967
B. SPECIFIC TO JOB
J1. FOR STEEL COLUMN'S/BASE PLATE LAYOUT PLAN REFER
DRAWING NO. P-77/2020/ST/ST-31.
J2. FOR STEEL PLATFORM FRAMING PLAN REFER DRAWING
NO. P-77/2020/ST/ST-32.
J3. FOR STEEL ROOF FRAMING PLAN REFER DRAWING
NO. P-77/2020/ST/ST-33.
J4. FOR SECTIONS REFER DRAWING NO. P-77/2020/ST/ST-35 &
P-77/2020/ST/ ST-36.
J5. FOR ERECTION METHODOLOGY REFER DRAWING NO.
P-77/2020/ST/ST-37.
J6. FOR ERECTION SEQUENCING REFER DRAWING NO.
P-77/2020/ST/ST-38.
J7. CONNECTION DETAILS OF PART-2 REFER DRAWING NO.
P-77/2020/ST/ST-39.
J8. CONNECTION DETAILS OF PART-3 REFER DRAWING NO.
P-77/2020/ST/ST-40.
J9. CONNECTION DETAILS OF PART-4 REFER DRAWING NO.
P-77/2020/ST/ST-41.
J10. CONNECTION DETAILS OF PART-1 REFER DRAWING NO.
P-77/2020/ST/ST-42.

NOTES :-

STRUCTURAL STEEL WORK SHALL CONFORM TO


OUT LINE CONSTRUCTION SPECIFICATION OF DMRC

The responsibility of control, check and verificationof accuracy,


correctness complenteness integration and full compliance of
contract provision in respect of design analysis and drawings
ISSUED DRAWING REFERENCES KEY PLAN rests with the design consultant. GENERAL NOTES: CRD DRAWINGS
S. No. DOC. NO. DESCRIPTION 1. ALL DIMENSION ARE IN MILLIMETERS & LEVELS IN METERS UNLESS OTHERWISE STATED.
"Notice of No Objections" from Employer is being accorded for design principles. However the overall
DELHI METRO RAIL CORPORATION LTD.

Approved by. : 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. responsibility for the detailing and design accuracy lies with DDC.
THIS DRAWING IS THE PROPERTY OF

DEALT BY: Design by. : Checked by. : 3. ANY DISCREPENCIES MUST BE BROUGHT TO THE NOTICE OF DMRC AND DDC IN WRITING BEFORE
EXECUTION OF WORK AT SITE. COMPANY APPROVAL BY DMRC
AVADH MUTHU HIMANSHU L.K.TYAGI 4. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURAL, MGR/ ARCH DY. CA (Architecture) CA (Architecture)
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL & TRAFFIC MANAGEMENT DRAWINGS.

STRUCTURAL
DGM/ CIVIL ED/ CIVIL/ OPM CSC

STRUCTURAL ENGINEER ARCHITECTURAL CONSULTANT MGR/ DESIGN DY. CE/ DESIGN GM/ Technical

DMRC GM/ S&T DGM/ E&M GM/ E&M (O&M)

ISA PROJECTS CONSULTING PVT. LTD. CLIENT DELHI METRO RAIL CORPORATION LTD.
RP-12, Sector 132, DATE CONTRACT NO.
LKT Engineering Consultants Ltd. NOIDA, U.P. PROJECT Skywalk Connection at New Delhi Railway Station 22/07/2020
10/14 , S u b h a s h N a g a r, PH: 9412224278, +120-6402546, 47, 48
REV. SCALE:
New Delhi-110027, Phone:+ 011-4 5 5 6 5 8 1 4 - 1 8 WEBSITE: www.isaprojects.com
R1 EMAIL: admin@isaprojects.com
DRAWING NO. P-77/2020/ST/ST-39 R1 1:300
11-08-2020 ADD GROUTING info@lktengineering.com
SHEET NO. STATUS
http//:-www.lktengineering.com FOB CONNECTION DETAILS OF PART-2
DATE REV. DESCRIPTION DRAWN DESIGNED CHECKED APPROVED DRAWING TITLE
(3OF4) CRD