You are on page 1of 1

DESIGN BY:

PR INFRACON PVT. LTD DRAWN VIRENDER SCALES


THIS DRAWING IS THE PROPERTY OF ``P.R.INFRACON Pvt.Ltd.''
DESIGN MANINDER
ANY DUPLICATION IN PART OR WHOLE WILL CONSTITUTE

AS ``A COPYRIGHT VIOLATION'' CHECKED MANINDER DATE 27-01-2022


BLSHED/PR/01/22/03

G1. DO NOT SCALE THE DRAWING FOLLOW ONLY FIGURED


DIMENSIONS.
G2. ALL STRUCTURAL DRAWINGS SHOULD BE READ IN
CONJUCTION WITH RELEVANT ARCHITECTURAL DRAWINGS.
ANY DISCREPANCY OR AMBIGUITY IN EITHER SHOULD
BE BROUGHT TO THE NOTICE OF THE ARCHITECT.
G3. ALL DIMENSIONS AND LEVELS ARE IN mm.

RELATIVE TO THIS LEVEL.

1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS IN METRES


UNLESS OTHERWISE SPECIFIED.
2. DIMENSIONS ARE NOT TO BE SCALED. ONLY WRITTEN
DIMENSIONS SHALL BE FOLLOWED.
3. ALL SQUARE HOLLOW SECTIONS (SHS) SHALL BE YST 310 GRADE
CONFORMING TO IS:4923-1997.
4. ALL CIRCULAR HOLLOW SECTIONS (CHS) SHALL BE YST 310 GRADE
CONFORMING TO IS:1161-1998.
5. ALL STRUCTURAL STEEL PLATES AND ROLL SECTIONS SHALL BE
CONFORMING TO IS 2062-2006.
6. THICKNESS OF GUSSET PLATES SHALL BE AS GIVEN BELOW:
a). VERTICAL GUSSET ON INNER FACE OF BOTTOM CHORD
(CONNECTING WITH FLOOR BEAM & OTHER MEMBERS) SHALL
16 mm THICK.
b). ALL OTHER GUSSET PLATES SHALL BE 10 mm THICK.
7. ALL WELDING SHALL CONFORM TO IS: 816-1969. ALL WELDS SHALL
BE SHOP WELDS EXCEPT THE WELDS AT FOLLOWING LOCATIONS:
a). WELD OF BOTTOM/TOP BRACING CONNECTIONS.
b). WELD OF FLOOR BEAM/TOP CROSS BEAM CONNECTION.
8. ALL WELDS SHALL BE CONTINOUS FILLED WELDS (UNLESS
NOTED OTHERWISE) AS PER THICKNESS GIVEN BELOW.
a). WELD OF CAP PLATE WITH COLUMN & CAP PLATE STIFFNER
SHALL BE 10mm.
b). WELD OF BASE PLATE WITH COLUMN & BASE PLATE STIFFNER
SHALL BE 10mm.
c). ALL OTHER WELDS SHALL BE 6mm.
9. ALL BOLTS AND NUTS SHALL CONFORM TO IS:1367(PART3):2002.
10. ALL HOLES FOR BOLT SHALL BE D+1.5mm. WHERE D= DIAMETER
OF BOLT.
11. THE CONTACT SURFACE AT FOLLOWING LOCATION SHALL BE
MACHINED TO GIVE A PERFECT BEARING.
a). STEEL COLUMN AT BASE/CAP PLATE.
b). STEEL TRUSS MEMBERS AT END PLATE (SPLICE LOCATIONS).
12. CUTTING LENGTH OF ALL MEMBERS AND GUSSETS TO BE
PURLIN ( 1SMC 125 ) FINALIZED BY FULL SCALE SHOP LAYOUT.
13. ALL DIMENSIONS TO BE CONFIRMED TO AT SITE BEFORE CUTTING
OF MEMBERS.

TRUSS AND PURLIN PLAN 14. OPEN ENDS OF ALL HOLLOW SECTIONS SHALL BE SEALED WITH
6mm THICK WELDED PLATE.
15. ADDITIONAL BRACING/STIFFENERS MAY HAVE TO BE PROVIDED
FOR MAINTAINING GEOMETRIC STABILITY DURING ERECTION/
CONSTRUCTION AS PER THE CHOSEN SCHEME OF ERECTION
THESE DETAIL SHALL BE INCLUDED IN THE FABRICATION
DRAWINGS TO BE PREPARED BY THE CONSTRUCTION AGENCY.
16. ALL HOLES NECESSARY FOR ERECTION BOLTS SHALL BE PLUGED
FULLY AFTER SUCCESSFUL COMPLETION OF ERECTION WORK.
17. FABRICATION AND ERECTION OF STRUCTURAL STEEL WORKS
SHALL CONFORM TO IS:7205-1974 &AND IS:7215-1974.
590

1290
700
450

200
450

450
600

GUSSET PLATE ( PL-1 )


TYP.
200 500
600

700
200
600

300
450

450

(TYP.) DETAIL 'A'


200 500 DETAIL AT A

600
600

300

450
600

VIEW-1
600
450

SECTION A-A
100

PEDESTAL

(TYP.) COLUMN ELEVATION

BASE PLATE SECTION 2-2


800X800X32 MM

You might also like