You are on page 1of 5

Mat Foundation Design Page 1 of 5

DESIGN OF MAT FOUNDATION

Mat Foundation Design(BS 8110) - Metric


Job Details

Job Name : mat


Included
X (m) Y (m) Z (m)
Support
671 0.00 -0.40 0.00
672 2.00 -0.40 0.00
673 0.00 -0.40 2.00
674 2.00 -0.40 2.00

Load Details

Included Loads

Load Case No 1: DEAD LOAD

Load Type : Primary

Serviceability Factor : 1.00

Design Factor : 1.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


For the loads shown in this table, the sign convention is the same as that for JOINT LOADS in STAAD.Pro when global Y is the vertical
axis.

Fy
(kN)
Fx Fz Mx Mz
NODE NO. Downwards is
(kN) (kN) (kNm) (kNm)
negative Upwards is
positive

671 -0.22 -12.28 -0.17 -0.03 0.05


672 0.22 -12.28 -0.17 -0.03 -0.05
673 -0.22 -12.28 0.17 0.03 0.05
674 0.22 -12.28 0.17 0.03 -0.05

Load Case No 2: WATER LOAD

Load Type : Primary

Serviceability Factor : 1.00

Design Factor : 1.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


For the loads shown in this table, the sign convention is the same as that for JOINT LOADS in STAAD.Pro when global Y is the vertical
axis.

file:///C:/Users/MG%20VOWGAS/Desktop/FOLDERS/OKEBEN%20SERVICES/STA... 06/11/2020
Mat Foundation Design Page 2 of 5

Fy
(kN)
Fx Fz Mx Mz
NODE NO. Downwards is
(kN) (kN) (kNm) (kNm)
negative Upwards is
positive

671 -0.78 -94.75 -0.57 -0.04 0.04


672 0.78 -94.75 -0.57 -0.04 -0.04
673 -0.78 -94.75 0.57 0.04 0.04
674 0.78 -94.75 0.57 0.04 -0.04

Load Case No 101: SL:1.000 x DL


Load Type : Service
Serviceability Factor : 1.00
Design Factor : 0.00

Included Primary Load Case Factor


DEAD LOAD 1.00

102: SL:1.000 x DL+1.000 x


Load Case No
LL
Load Type : Service
Serviceability Factor : 1.00
Design Factor : 0.00

Included Primary Load Case Factor


DEAD LOAD 1.00
WATER LOAD 1.00

Load Case No 201: UL:1.000 x DL


Load Type : Ultimate
Serviceability Factor : 0.00
Design Factor : 1.00

Included Primary Load Case Factor


DEAD LOAD 1.00

202: UL:1.000 x DL+1.600 x


Load Case No
LL
Load Type : Ultimate
Serviceability Factor : 0.00
Design Factor : 1.00

Included Primary Load Case Factor


DEAD LOAD 1.00
WATER LOAD 1.60

Load Case No 203: UL:1.400 x DL


Load Type : Ultimate
Serviceability Factor : 0.00
Design Factor : 1.00

Included Primary Load Case Factor


DEAD LOAD 1.40

204: UL:1.400 x DL+1.600 x


Load Case No
LL
Load Type : Ultimate
Serviceability Factor : 0.00
Design Factor : 1.00

Included Primary Load Case Factor


DEAD LOAD 1.40
WATER LOAD 1.60

file:///C:/Users/MG%20VOWGAS/Desktop/FOLDERS/OKEBEN%20SERVICES/STA... 06/11/2020
Mat Foundation Design Page 3 of 5

213: UL:1.200 x DL+1.200 x


Load Case No
LL
Load Type : Ultimate
Serviceability Factor : 0.00
Design Factor : 1.00

Included Primary Load Case Factor


DEAD LOAD 1.20
WATER LOAD 1.20

Properties Details

Region Thickness(m) Material


slab 0.30 Concrete

Soil Details

Boundary Subgrade Modulus Soil Height Above Mat Soil Density Applied Load due to Soil
slab 12000.00kN/m2/m 0.00m 22.00kN/m3 0.00kN/m^2

Mat Dimension

Boundary Name : AutoGen674


Node No X Coor(m) Y Coor(m) Z Coor(m)
25 1.92 -0.40 1.92
26 2.08 -0.40 1.92
27 2.08 -0.40 2.08
28 1.92 -0.40 2.08
Boundary Name : AutoGen673
Node No X Coor(m) Y Coor(m) Z Coor(m)
21 -0.08 -0.40 1.92
22 0.08 -0.40 1.92
23 0.08 -0.40 2.08
24 -0.08 -0.40 2.08
Boundary Name : AutoGen672
Node No X Coor(m) Y Coor(m) Z Coor(m)
17 1.92 -0.40 -0.08
18 2.08 -0.40 -0.08
19 2.08 -0.40 0.08
20 1.92 -0.40 0.08
Boundary Name : AutoGen671
Node No X Coor(m) Y Coor(m) Z Coor(m)
13 -0.08 -0.40 -0.08
14 0.08 -0.40 -0.08
15 0.08 -0.40 0.08
16 -0.08 -0.40 0.08
Boundary Name : slab
Node No X Coor(m) Y Coor(m) Z Coor(m)
9 -0.40 0.00 -0.40
10 2.50 0.00 -0.40
11 2.50 0.00 2.50
12 -0.40 0.00 2.50

Analysis Results

file:///C:/Users/MG%20VOWGAS/Desktop/FOLDERS/OKEBEN%20SERVICES/STA... 06/11/2020
Mat Foundation Design Page 4 of 5

Node Displacement Summary Table


Rx Ry Rz
- Node Number Load Case Dx(mm) Dy(mm) Dz(mm)
(Rad) (Rad) (Rad)

Max Dx 1 101 0.00 -0.60 0.00 0.00 0.00 -0.00


Max Dy 1 101 0.00 -0.60 0.00 0.00 0.00 -0.00
Max Dz 1 101 0.00 -0.60 0.00 0.00 0.00 -0.00
Max Rx 1 101 0.00 -0.60 0.00 0.00 0.00 -0.00
Max Ry 1 101 0.00 -0.60 0.00 0.00 0.00 -0.00
Max Rz 2 213 0.00 -0.72 0.00 0.00 0.00 0.00
Min Dx 1 101 0.00 -0.60 0.00 0.00 0.00 -0.00
Min Dy 1 203 0.00 -0.84 0.00 0.00 0.00 -0.00
Min Dz 1 101 0.00 -0.60 0.00 0.00 0.00 -0.00
Min Rx 4 213 0.00 -0.72 0.00 -0.00 0.00 -0.00
Min Ry 1 101 0.00 -0.60 0.00 0.00 0.00 -0.00
Min Rz 1 101 0.00 -0.60 0.00 0.00 0.00 -0.00

Plate Stress Summary Table


SQx SQy Sx Sy Sxy Mx My Mxy
- Plate Load Case
(kN/m2 ) (kN/m2) (kN/m2) (kN/m2) (kN/m2) (kN-m/m) (kN-m/m) (kN-m/m)

Max SQX 28 203 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Max SQY 4 203 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Max SX 1 101 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Max SY 1 101 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Max SXY 1 101 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Max MX 27 203 -0.00 -0.00 0.00 0.00 0.00 0.00 -0.00 0.00
Max MY 75 203 -0.00 -0.00 0.00 0.00 0.00 -0.00 0.00 0.00
Max MXY 68 203 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Min SQX 36 203 -0.00 -0.00 0.00 0.00 0.00 0.00 0.00 0.00
Min SQY 76 203 -0.00 -0.00 0.00 0.00 0.00 0.00 0.00 0.00
Min SX 1 101 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Min SY 1 101 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Min SXY 1 101 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Min MX 81 203 0.00 0.00 0.00 0.00 0.00 -0.00 -0.00 -0.00
Min MY 81 203 0.00 0.00 0.00 0.00 0.00 -0.00 -0.00 -0.00
Min MXY 73 213 -0.00 0.00 0.00 0.00 0.00 0.00 0.00 -0.00

Base Pressure Summary for Service Load conditions


Base Pressure
- Node X-Coor(m) Y-Coor(m) Z-Coor(m) Load Case
(kN/m2)
Maximum Base
2 2.50 0.00 -0.40 101 7.20
Pressure
Minimum Base
8 0.89 0.00 -0.40 101 7.20
Pressure

Contact Area
Load Case Area in Contact(m2) % of Total Area Area out of Contact(m2) % of Total Area
101 8.41 100.00 0.00 0.00
102 8.41 100.00 0.00 0.00

file:///C:/Users/MG%20VOWGAS/Desktop/FOLDERS/OKEBEN%20SERVICES/STA... 06/11/2020
Mat Foundation Design Page 5 of 5

201 8.41 100.00 0.00 0.00


202 8.41 100.00 0.00 0.00
203 8.41 100.00 0.00 0.00
204 8.41 100.00 0.00 0.00
213 8.41 100.00 0.00 0.00

Sliding Check
Sliding Force, Fx Sliding Force, Fz Resisting Force FOS(x) FOS(z)
Load Case No
(kN) (kN) (kN) (Along X Direction) (Along Z Direction)
101 0.00 0.00 24.22 N/A N/A
102 0.00 0.00 24.22 N/A N/A

Overturning Check
Distance to Distance to
Critical Critical Overturning Overturning Resisting Resisting FOS(x) FOS(z)
Load Case
Location Location Moment, Mx Moment, Mz Moment, Rx Moment, Rz (About X (About Z
No
Along X Along Z (kNm) (kNm) (kNm) (kNm) Direction) Direction)
(m) (m)
101 2.50 -0.40 -0.00 -0.00 87.80 87.80 N/A 3658154.09
102 2.50 -0.40 -0.00 -0.00 87.80 87.80 N/A N/A

Mat Self Weight = 60.55 kN

Centre of Gravity of Mat (From Origin) = {1.05, 0.00, 1.05} m

Punching Shear Check

Column No. Load Case Service Stress (kN/m) Corner 1 (kN/m) Corner 2 (kN/m) Corner 3 (kN/m) Corner 4 (kN/m) Design Status
671 204 1078.76 231.20 230.72 231.16 231.65 Pass
672 204 1078.76 155.33 155.67 155.97 155.63 Pass
673 204 1078.76 155.97 155.64 155.33 155.66 Pass
674 204 1078.76 95.27 95.53 95.29 95.03 Pass

Design Parameters

Min Max
Top Bottom Pedestal Pedestal Min Max Wood and
Panel f 'c Pedestal Bar Bar
fy (kN/m2) Cover Cover Min Bar Max Bar Spacing Spacing Armer
Name (kN/m2) Cover(m) Size Size
(m) (m) Size (mm) Size (mm) (mm) (mm) Moment
(mm) (mm)
slab 410000.07 30000.01 0.04 0.04 0.04 12 12 12 60 100.00 200.00 Not Used

Design Output

Top of Mat Longitudinal Direction

Top of Mat Transverse Direction

Bottom of Mat Longitudinal Direction

Bottom of Mat Transverse Direction

Print Calculation Sheet

file:///C:/Users/MG%20VOWGAS/Desktop/FOLDERS/OKEBEN%20SERVICES/STA... 06/11/2020