You are on page 1of 49

Unity and OPC software

Catalog
January 2018

Unity Pro
Unity EFB Toolkit
Unity DIF
Unity Loader
Unity specific Libraries

OPC Factory Server


Quick access to Product information
Select your Catalog, your Training

With just 3 clicks, you can reach the 7,000 pages


of the Industrial Automation & Control catalog,
in both English and French.
–– Digi-Cat is available on a USB key (for PC). To get your Digi-Cat, please
contact your local center
–– Download Digi-Cat from this address:

http://digi-cat.schneider-electric.com/download.html

Find your training


–– Find the right training for your needs
–– Locate the training center with the selector tool, using this address:
http://www.schneider-electric.com/b2b/en/services/training/technical-training.jsp

then click on
General contents

Unity Pro software. . . . . . . . . . . . . . . . . . . 1

Companion software. . . . . . . . . . . . . . . . . 2

OPC data server software,


Product reference index. . . . . . . . . . . . . . 3

10
In this catalog, each time words which refer to Safety without precision, must be
understood according to “Functional Safety”: IEC61508 & IEC61511.

1
1

10

1/0
Contents 1 - Unity Pro software

Unity Pro software


Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1/2

bb Presentation............................................................................................ page 1/6


1
bb Cyber security......................................................................................... page 1/6
bb FDT/DTM.................................................................................................. page 1/6
bb Programming languages....................................................................... page 1/7
bb Functions................................................................................................ page 1/8 2
bb Communication drivers....................................................................... page 1/18
bb Windows OS compatibility................................................................... page 1/18
bb Unity Pro update................................................................................... page 1/19
bb References............................................................................................ page 1/20
3

10

1/1
Selection guide Software
Unity Pro software
Versions ≥ V13

Unity Pro programming software for Modicon M340 M, Modicon M580 M5, Modicon M580 Safety M5S, Modicon Momentum MM, Premium P, Unity Pro programming software for Modicon M340 M , Modicon M580 M5, Modicon M580 Safety M5S, Modicon Momentum MM, Premium P,
Quantum Q, Quantum Safety QS and Modicon distributed I/O D platforms Quantum Q, Quantum Safety QS and Modicon distributed I/O D platforms

1 1

IEC 61131-3 Instruction List (IL) M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D M - M5 - M5S - MM - P - Q - D


languages Ladder (LD) M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D M - M5 - M5S - MM - P - Q - D

2 Structured Text (ST)


Function Block Diagram (FBD)
M - MM - D
M - MM - D
M - M5 - MM - P - Q - D
M - M5 - MM - P - Q - D
M - M5 - MM - P - Q - D
M - M5 - MM - P - Q - D
M - M5 - M5S - MM - P - Q - D
M - M5 - M5S - MM - P - Q - D 2
Sequential Function Chart (SFC)/Grafcet M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D M - M5 - M5S - MM - P - Q - D
Ladder Logic Language LL984 M - MM M - M5 - MM - Q M - M5 - MM - Q M - M5 - M5S - MM - Q
Programming Multitask programming (Master, fast and M - MM (master task only) - D M - M5 - MM (master task only) - P - Q - D M - M5 - MM (master task only) - P - Q - D M - M5 - M5S - MM (master task only) - P - Q - D
services event-triggered)
Multitask programming (Master, fast, auxiliary M5 M5 - P (TSXP575p) - Q (140CPU651/671) - D M5 - M5S - P (TSXP575p) - Q (140CPU651/671) - D

3 3
and event-triggered)
Functional view and function modules M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D M - M5 - M5S - MM - P - Q - D
DFB editor and instances M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D M - M5 - M5S - MM - P - Q - D
DDT compound data editors M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D M - M5 - M5S - MM - P - Q - D
Data structure instances and tables M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D M - M5 - M5S - MM - P - Q - D
EF and EFB libraries M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D M - M5 - M5S - MM - P - Q - D
User-definable control loops P (TSXP572p/3p/4p) - D P (TSXP572p/3p/4p/5p) - D P (TSXP572p/3p/4p/5p) - D

4 Programmable control loops (with process


control FB library)
M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D M - M5 - M5S - MM - P - Q - D
4
Safety function block libraries M5S
Motion function block (MFB) libraries M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - D M - M5 - M5S - MM - P - D
Hot Standby PLC redundancy system P (TSXH5724M/44M) - D P (TSXH5724M/44M) - Q (140CPU67160) - D P (TSXH5724M/44M) - Q (140CPU67160) - D
System and Application diagnostics M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D M - M5 - M5S - MM - P - Q - D
Bus and network configuration to slave devices M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D M - M5 - M5S - MM - P - Q - D

5 5
(Modicon distributed I/O, etc.)
Debugging PLC simulator M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D M - M5 - M5S - MM - P - Q - D
and display Hypertext link animations in graphic languages M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D M - M5 - M5S - MM - P - Q - D
services
Step by step execution, Breakpoint, M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D M - M5 - M5S - MM - P - Q - D
Watchpoint
Trending tool M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D M - M5 - M5S - MM - P - Q - D
Operator screens, Animation tables M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D M - M5 - M5S - MM - P - Q - D

6 Other
Diagnostics viewer
Creation of hyperlinks
M - MM - D
M - MM - D
M - M5 - MM - P - Q - D
M - M5 - MM - P - Q - D
M - M5 - MM - P - Q - D
M - M5 - MM - P - Q - D
M - M5 - M5S - MM - P - Q - D
M - M5 - M5S - MM - P - Q - D 6
services XML/XVM import/export M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D M - M5 - M5S - MM - P - Q - D
Application converters (Modsoft, Concept, M M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D M - M5 - M5S - MM - P - Q - D
ProWORX, PL7)
Utilities for updating PACs and Advantys M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D M - M5 - M5S - MM - P - Q - D
operating system

7 7
Communication drivers for Modicon platforms M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D M - M5 - M5S - MM - P - Q - D
Unity Pro servers - Openness (OFS, M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D M - M5 - M5S - MM - P - Q - D
3rd party tools)
Online modification of the configuration M5 - Q M5 - Q M5 - M5S - Q
Online modification of the program M - MM - Q M - M5 - MM - P - Q M - M5 - MM - P - Q M - M5 - M5S - MM - P - Q
Importing of applications (Modsoft, Concept, M - MM M - MM - Q M - M5 - MM - Q M - M5 - M5S - MM - Q
ProWORX) written in LL984 language

8 8
Data dictionary, Dynamic exchange with M - MM - D M - M5 - MM - P - Q - D M - M5 - P - Q - D M - M5 - M5S - P - Q - D
SCADA through OFS
Static exchange via XML/XVM export files M - MM - D M - M5 - MM - P - Q - D M - M5 - MM - P - Q - D M - M5 - M5S - MM - P - Q - D
Compatible Modicon M340 CPUs M All models All models All models All models
Modicon Modicon M580 CPUs M5 – BMEP5810/5820/5830/BMEH5820 All models All models
platforms
Modicon M580 Safety CPUs M5S – BMEP5810/5820/5830/BMEH5820 All models All models
Modicon Momentum CPUs MM 171CBU78090/98090/98091 171CBU78090/98090/98091 171CBU78090/98090/98091 171CBU78090/98090/98091

9 9
Premium CPUs P – TSXP57104M/1634M/154M TSXP574634/454M All models All models
TSXP57204M/2634M/254M TSXH5724/44M
TSXP57304M/3634M/354M
Quantum CPUs Q – 140CPU31110 All models All models
140CPU43412U
140CPU53414U
Quantum Safety CPUs S – – – –
Compatible Modicon distributed I/O D STB, OTB, TM7, ETB, Momentum STB, OTB, TM7, ETB, Momentum STB, OTB, TM7, ETB, Momentum STB, OTB, TM7, ETB, Momentum

10 Software name
Unity Pro package
Unity Pro Small
UNYSPUSppV1X
Unity Pro Large
UNYSPULppV1X
Unity Pro Extra Large
UNYSPUEppV1X
Unity Pro Extra Large Safety
UNYSPUXppV1X
10
License, see page 1/21 1/22 1/23 1/24

1/2 1/2
1/3
Selection guide Software
Unity Pro software
Unity Pro V7 XL Safety for Quantum

Unity Pro programming software for Modicon M340 M, Modicon M580 M5, Modicon M580 Safety M5S, Modicon Momentum MM, Premium P, Unity Pro programming software for Modicon M340 M , Modicon M580 M5, Modicon M580 Safety M5S, Modicon Momentum MM, Premium P,
Quantum Q, Quantum Safety QS and Modicon distributed I/O D platforms Quantum Q, Quantum Safety QS and Modicon distributed I/O D platforms

1 1

IEC 61131-3 Instruction List (IL) Q M - MM - P - D


languages Ladder (LD) Q - QS M - MM - P - D

2 2
Structured Text (ST) Q M - MM - P - D
Function Block Diagram (FBD) Q - QS M - MM - P - D
Sequential Function Chart (SFC)/Grafcet Q M - MM - P - D
Ladder Logic Language LL984 Q M - MM
Programming Multitask programming (Master, fast and Q M - MM (master task only) - P - D
services event-triggered)
Multitask programming (Master, fast, auxiliary Q (140CPU651/671) P (TSXP575p) - D
and event-triggered)
3 Functional view and function modules
DFB editor and instances
Q - QS
Q - QS
M - MM - P - D
M - MM - P - D
3
DDT compound data editors Q M - MM - P - D
Data structure instances and tables Q M - MM - P - D
EF and EFB libraries Q M - MM - P - D
User-definable control loops P (TSXP572p/3p/4p/5p) - D
Programmable control loops (with process Q M - MM - P - D
4 control FB library)
Safety function block libraries QS D
4
Motion function block (MFB) libraries M - MM - P - D
Hot Standby PLC redundancy system Q (140CPU67160) P (TSXH5724M/44M) - D
System and Application diagnostics Q - QS M - MM - P - D
Bus and network configuration to slave devices Q M - MM - P - D
(Modicon distributed I/O, etc.)

5 Debugging PLC simulator


and display Hypertext link animations in graphic languages
services
Q - QS
Q - QS
M - MM - P - D
M - MM - P - D 5
Step by step execution, Breakpoint, Q - QS M - MM - P - D
Watchpoint
Trending tool Q - QS M - MM - P - D
Operator screens, Animation tables Q - QS M - MM - P - D
Diagnostics viewer Q - QS M - MM - P - D

6 6
Other Creation of hyperlinks Q - QS M - MM - P - D
services XML/XVM import/export Q - QS M - MM - P - D
Application converters (Modsoft, Concept, Q M - MM - P - D
ProWORX, PL7)
Utilities for updating PACs and Advantys Q M - MM - P - D
operating system
Communication drivers for Modicon platforms Q - QS M - MM - P - D
Unity Pro servers - Openness (OFS, Q - QS M - MM - P - D
7 3rd party tools)
Online modification of the configuration
7
Online modification of the program
Importing of applications (Modsoft, Concept, Q M - MM
ProWORX) written in LL984 language
Data dictionary, Dynamic exchange with Q - QS M-P-D
SCADA through OFS

8 8
Static exchange via XML/XVM export files Q - QS M - MM - P - D
Compatible Modicon M340 CPUs M – All models
Modicon Modicon M580 CPUs M5 – –
platforms Modicon M580 Safety CPUs M5S – –
Modicon Momentum CPUs MM – 171CBU78090/98090/98091
Premium CPUs P – TSXP57104M/1634M/154M TSXP574634M/454M
TSXP57204M/2634M/254M TSXP575634M/554M
TSXP57304M/3634M/354M TSXP576634M

9 Quantum CPUs Q 140CPU31110


140CPU43412U
140CPU65150/60
140CPU65260

TSXH5724M/44M
9
140CPU53414U 140CPU67160
140CPU67260/61
Quantum Safety CPUs S 140CPU65160S –
140CPU67160S
Compatible Modicon distributed I/O D – STB, OTB, TM7, ETB, Momentum

10 Software name Unity Pro Extra Large Safety Unity Pro Extra Large Safety 10
Unity Pro package UNYSPUXppV1X UNYSPUXppV1X
License, see page www.schneider-electric.com

1/3
1/4 1/5
1/3
Presentation, Software
functions Unity Pro software
Small/Large/Extra Large/Extra Large Safety

Presentation
This catalog describes Unity Pro software version 13, which is the latest version
1 available.

Unity Pro is the common programming, debugging and operating software for the
Modicon M340, M580, M580S, Premium, Momentum and Quantum ranges.
Unity Pro
Note: Please, use Unity Pro software V7 for Quantum SIL3 (safety integrity level 3).
Unity Pro is multitasking software offering the following features:
2 bb All-in-one software
bb Five IEC 61131-3 programming languages
bb LL 984 programming language
bb Device integration with FDT/DTM standard
bb Integrated, customizable DFB library
bb PLC simulator on PC for program validation prior to installation
bb Built-in tests and diagnostics
3 bb Wide range of online services
bb Cybersecurity

Unity Pro supports the new M580 Safety PACs, mixing process and safety in a
single project. It allows to:
bb Optimize engineering time
bb Simplify programming with IEC61508 functions
4 bb Facilitate maintenance

ur
Sec ity Cybersecurity
Schneider Electric constantly endeavours to maintain the security of its systems.
Security guidelines are available for our customers to ensure their systems are
protected from attack.

5 With the Modicon M340, M580, M580S, Premium, Momentum and Quantum
automation platforms:
bb Protection against remote programming changes via a password
bb Option to enable or disable HTTP or FTP services

With the Modicon M580 automation platform:

6 bb Log of security events in the SYSLOG database


bb Extended Ethernet services management (DHCP, etc.) can be set for each user
in the Access Control List
bb More secure IPSec communication between Unity Pro or SCADA and PAC

FDT/DTM function
Unity Pro facilitates integration of fieldbus architectures into engineering control
7 systems using FDT/DTM technology:
bb FDT (Field Device Tool) is the container which supports the device DTMs.
bb DTM (Device Type Manager) is the configuration tool for devices with integrated
graphic interfaces. It contains the properties specific to each device.

In addition to the FDT/DTM standard, Unity Pro uses specific information from the
Master DTM created for the Profibus Remote Master (PRM) module, the HART
8 DTM editor (Modicon STB island) module, the Premium ISPY101 weighing module, Altivar process drive integration
and the Modbus/TCP and EtherNet/IP network modules BMXNOC0401 and
BMENOC03p1.

Use of the Master DTM allows Unity Pro to perform the following actions:
bb Manage the PAC I/O scan
bb Create the application variables based on the description of the process objects
9 available from the connected DTM devices
bb Manage synchronization with the PAC configuration
DTM hardware catalog bb Create a generic DTM from the description files (GSD or EDS)

10

Selection guide:
page 1/2

1/6
Functions (continued) Software
Unity Pro software
Small/Large/Extra Large/Extra Large Safety

FDT/DTM function (continued)


The DTM configuration is stored in the PAC memory so that the application can be
downloaded in its entirety. It is also saved in the PAC project file (STU), the archive
file (STA), and the full application exchange file (ZEF).
1
A third-party DTM can be installed in the DTM hardware catalog.
The DTM hardware catalog can be used to sort or filter the DTMs according to
various criteria such as Device, Vendor, Groups or Protocols.

The DTM Browser in Unity Pro:


bb Displays the fieldbus topologies in a tree structure
2
DTM browser and DTM context menu bb Allows the user to configure the DTM devices:
vv add and delete DTMs
vv connect and disconnect DTMs to/from their physical devices
vv display and print the properties of a DTM
vv transfer DTM configuration data to and from the physical device
vv functions specific to the DTM, via the Device menu 3
The fieldbus lookup function scans the physical devices in a fieldbus network and
adds the selected devices to the DTM Browser.

5
Fieldbus lookup screen

Programming languages
The five IEC 61131-3 compliant languages
The five graphical or textual languages available in Unity Pro are used for
6
programming Modicon M340, Modicon M580, Modicon M580 Safety,
Modicon Momentum, Premium and Quantum automation platforms.

The three graphical languages are:


bb Ladder (LD) language
bb Function Block Diagram (FBD)
bb Sequential Function Chart (SFC) or Grafcet
7
The two textual languages are:
bb Structured Text (ST)
bb Instruction List (IL)

FBD language editor


For these five languages, you can use the standard set of instructions compliant with
IEC standard 61131-3 to create applications which can be transferred from one
8
platform to another. Unity Pro software also provides extensions to this standard set
of instructions. As they are specific to Modicon M340, Modicon M580,
Modicon M580 Safety, Modicon Momentum, Premium and Quantum automation
platforms, these extensions support the development of more complex applications
in order to maximize the potential of the specific features of each of these platforms.

LL984 language
9
LL984 (Ladder Logic 984) language enables migration from legacy Modicon ranges.
It is used to program Modicon M580, Modicon M580 Safety, Modicon M340,
Momentum and Quantum automation platforms.

10

Selection guide:
page 1/2

1/7
Functions (continued) Software
Unity Pro software
Small/Large/Extra Large/Extra Large Safety

m
-m
e-to ark Common Safety on Modicon M580 (1)
Presentation
et
Ti

1 Unity Pro user-friendly interface for Modicon automation platforms family is now
available for safety.

Unity Pro allows to:


bb manage a complete control and safety automation system from design to
operation and maintenance.
bb increase productivity during engineering, commissioning and operation for both
2 process and safety, reducing time to market.

Unity Pro makes it possible to design a common safety architecture by executing:


bb safety functions of your process in specific safety tasks,
bb standard functions in other tasks.
All X80 safety I/O are managed through safety tasks, and standard and non
interfering X80 modules are managed in other tasks. So the mix of safety and
3 standard X80 modules is possible in the same M580 Safety PAC.

IEC 61131-3 compliant languages


FBD and LD are supported in SAFE task.
2 modes for operation and maintenance of SAFE task:
bb safety mode: in operation conditions, the safe task is running and is locked for

4
users.
bb maintenance mode: dedicated for maintenance operation in safety part of the
application.

Data editor
Process and safe data are managed in distinct M580 memory area. Unity Pro allows
to easily manage:

5 bb exchange of data between process and safe areas of the project in “Data Editor”
bb process data in “Process Data Editor”
bb safe data in “Safe Data Editor”

Safety function blocks


Unity Pro supports new M580 Safety offers with IEC61508 programming languages
and rich library of safety Function blocks.
6 Safety function block

Data editor
The data editor provides a single tool for performing the following editing tasks:
bb Declaration of data including variables and function blocks (declaration of their

7 type, instances and attributes)


bb Use and archiving of function block data types in different libraries
bb Hierarchical view of data structures
bb Searching, sorting and filtering of data
bb Creation of a hyperlink to access a description from any variable comment

The data is displayed in four tabs:

8 bb “Variables” tab for the creation and management of the following data instances:
Data editor
bits, words, double words, inputs/outputs, tables and structures
bb “DDT Types” tab for the creation of derived data types (tables and structures)
bb “Function Blocks” tab for the declaration of EFBs and DFBs
bb “DFB Types” tab for the creation of DFB user function block data types

Each data element has several attributes, of which:

9
bb Variable name and type are mandatory
bb Comment, physical address in the memory and initial values are optional

The data editor columns can be configured (number of columns, order). The
attributes associated with a variable can be displayed in a properties window.

This editor can be accessed at any time during programming by selecting variables

10
Data properties for data modification or creation.
(1) Available from V13

Selection guide:
page 1/2

1/8
Functions (continued) Software
Unity Pro software
Small/Large/Extra Large/Extra Large Safety

DFB user function blocks

1
With Unity Pro software, users can create their own function blocks for specific
application requirements on Modicon M340, Modicon M580, Modicon M580 Safety,
Modicon Momentum, Premium and Quantum platforms.

Once created and saved in the library, these user function blocks can be reused as
easily as EFBs (Elementary Function Blocks).

2
The user function blocks can be used to structure an application. They are used
when a program sequence is repeated several times in the application or for freezing
Design
a standard programming routine. They can be read-only or read/write. They can be
exported to the other Unity Pro applications.

Using a DFB in one or more applications:


bb simplifies program design and entry
bb improves program readability and understanding
bb facilitates program debugging (variables handled by the DFB are identified in the
data editor)
3
bb enables the use of private variables specific to the DFBs, which are independent
of the application

A DFB is set up in several stages:


bb The DFB is designed by assigning a name, a set of parameters (inputs, outputs,

Creating the code


public and private internal variables) and a comment to it via the data editor.
bb The code is created in one or more sections of the program, with the following
4
languages selected according to requirements: Structured Text, Instruction List,
Ladder or Function Block Diagram (ST, IL, LD or FBD).
bb The DFB can be stored in a library with an associated version number.
bb A DFB instance is created in the data editor or when the function is called in the
program editor.
bb This instance is used in the program in the same way as an EFB (the instance can
be created from within the program).
5

Use within the program

10

Selection guide:
page 1/2

1/9
Functions (continued) Software
Unity Pro software
Small/Large/Extra Large/Extra Large Safety

Function block libraries


The function and function block libraries manager contains the elements provided
1 with Unity Pro software. Functions and function blocks are organized into libraries,
which themselves consist of families. Depending on the type of PAC selected and
the processor model, users will have a subset of these libraries available to write
their applications. However, the “Base Lib” library contains a set of functions and
function blocks, for the majority of which compatibility is independent of the
platforms. In particular, it contains the blocks compliant with IEC 61131-3.
The “Base Lib” library is structured into families:
2 bb Timers and counters
bb Process control on integers
bb Table management
bb Comparison
bb Date and time management
bb Logic processing
bb Mathematical processing
3 Standard function block libraries
bb Statistical processing
bb Character string processing
bb Type-to-type data conversion

The “Base Lib” library, which covers standard automation functions, is supplemented
by other, more application-specific libraries and platform-specific functions:
bb Communication library, providing an easy means of integrating communication
4 programs from PACs with those used by HMIs from the PAC application program.
Like other function blocks, these EFBs can be used in any language to exchange
data between PACs or to deliver data to be displayed on an HMI.
bb Process control library. The CONT_CTL library can be used to set up process-
specific control loops. It offers controller, derivative and integral control functions and
additional algorithms, such as EFBs for calculating mean values, selecting a
maximum value, detecting edges or assigning a hysteresis to process values, etc.
5 bb Diagnostics library, which can be used to monitor actuators and contains EFBs
for active diagnostics, reactive diagnostics, interlocking diagnostics, permanent
process condition diagnostics, dynamic diagnostics, monitoring of signal groups, etc.
bb I/O management library, providing services to handle information exchanged
with hardware modules (formatting data, scaling, etc.).
bb Motion Function Blocks library, containing a set of predefined functions and
structures to manage motion controlled by drives and servo drives connected on
6 CANopen.
bb Motion library for motion control and fast counting.
bb System library, which provides EFBs for the execution of system functions,
including: evaluation of scan time, availability of several different system clocks, SFC
section monitoring, display of system status, management of files on the memory
cartridge of the Modicon M340 processor, M580 processor, etc.
bb Finally, a library named “obsolete”, containing the function blocks used by legacy
7 programming software needed to perform application conversions.

Management of user standards


Users can create libraries and families in order to store their own DFBs and DDTs.
This enhancement allows users to take advantage of programming standards
adapted to their needs, along with version management. This means that it is
possible to:
8 bb Check the version of the elements used in an application program against those
stored in the library
User libraries bb Perform an upgrade, if necessary

10

Selection guide:
page 1/2

1/10
Functions (continued) Software
Unity Pro software
Small/Large/Extra Large/Extra Large Safety

Debugging tools
Unity Pro software offers a complete set of tools for debugging Modicon M340,
M580, M580S, Momentum, Premium or Quantum applications. A tool palette
provides direct access to the main functions:
1
bb Dynamic program animation.
bb Setting of watchpoints or breakpoints (not authorized in event-triggered tasks).
bb Step-by-step program execution. A function in this mode enables section-by-
section execution. Instruction-by-instruction execution can be launched from the
previous breakpoint. Three execution commands are therefore possible when the
element to be processed is a subroutine (SR) or DFB user block instance:
vv Step Into: this command is used to move to the first element of the SR or DFB
2
Debugging tools: Dynamic animation/adjustment vv Step Over: this command is used to execute the entire SR or DFB
vv Step Out: this command is used to move to the next instruction after the SR or
DFB element
bb Independent execution of the master (MAST), fast (FAST), auxiliary (AUX) and
event-triggered (EVTi) tasks.

Animation of program elements


3
Dynamic animation is managed section-by-section. A button on the toolbar is used to
activate or deactivate animation for each section.
When the PAC is in RUN, this mode can be used to view simultaneously:
bb The animation of a program section, regardless of the language used.

Debugging tools: Watchpoint


bb The variables window containing the application objects created automatically
from the section viewed. 4
Animation table
Tables containing the variables of the application to be monitored or modified can be
created by data entry or initialized automatically from the selected program section.
The tables can be stored in the application and retrieved from there at a later date.

Unity Pro can be used to save, import and export Animation tables with predefined
5
set values. As it allows population of set values along with current values and vice
versa in the PAC, the Animation tables can be used as templates to make the
application easier to tune.

Debugging DFB user function blocks


Debugging tools: Breakpoint/step-by-step The parameters and public variables of these blocks are displayed and animated in
real time using animation tables, with the possibility of modifying and forcing the
6
required objects.
In exactly the same way as with other program elements, the watchpoint, breakpoint,
step-by-step execution and program code diagnostics functions can be used to
analyze the behavior of DFBs. Setting a breakpoint in a DFB user function block
instance stops execution of the task containing this block.
7
Debugging in Sequential Function Chart (SFC) language
The various debugging tools are also available in SFC language. However, unlike
other sections (IL, ST, LD or FBD), an SFC section executed step-by-step does not
stop execution of the task but instead freezes the SFC chart. Several breakpoints
can be declared simultaneously within a single SFC section.
8

10

Selection guide:
page 1/2

1/11
Functions (continued) Software
Unity Pro software
Small/Large/Extra Large/Extra Large Safety

PLC simulator

1
Unity Pro’s integrated simulator can be used to test the application program for
Modicon M340, M580, M580S, Momentum, Premium or Quantum automation
platforms from the PC terminal without having to connect to the processor. The
functions provided by the debugging tools are available for debugging the master,
Simulator control panel fast and auxiliary tasks.
As the simulator does not manage the PLC I/O, animation tables can be used to
simulate the state of inputs by forcing them to 0 or 1.

2
The simulator can be connected to third-party applications via an OPC server with
OFS (OPC Factory Server) software.

Trending tool
The trending tool allows easy monitoring of variables by detecting operating
problems or improving process performance. You can select any variable in your
3 application and start acquisition, save records, and analyze records with integrated
tools or Excel. The PAC mast scan can scan up to 16 variables.

4 Trending tool control panel

Documentation editor
The documentation editor is based on the Documentation Browser, which shows the
file structure in tree form.

5 It allows all or part of the application file to be printed on any graphics printer
accessible under Windows and using True Type technology, in A4 or US letter print
format.
The documentation editor supports the creation of user-specific files using the
following headings:
bb Title page
bb Contents

6 bb General information
bb Footer
bb Configuration
bb EF, EFB and DFB type function blocks
Accessing the documentation editor bb User variables
bb Communication
bb Project structure

7
bb Program
bb Animation tables and cross-references
bb Runtime screens

System Time stamping


8 System Mode allows Time Stamping of I/O or internal variables for easy
management via OFS and SCADA. Programming or use of any function block is not
required as the configuration is easy to perform in Unity Pro Data Editor supported
by OFS version 3.51.

10

Selection guide:
page 1/2

1/12
Functions (continued) Software
Unity Pro software
Small/Large/Extra Large/Extra Large Safety
Integrated diagnostics

Diagnostics integrated in Modicon M340, Modicon M580, Modicon M580 Safety, Premium and Quantum
automation platforms
Presentation 1
System diagnostics Diagnostics viewers

Vijeo Citect
Thin client Magelis iPC Higher-level
M.E.S.
2
Processor In-rack I/O Distributed
for system modules I/O modules
bits and on Ethernet Ethernet TCP/IP
words or I/O buses

Vijeo Designer
Cell level 3
Application diagnostics

Magelis Terminal

4
RUN ERR

I/O MB1

ETH ETH
100 STS
ETH LNK/ACT

Quantum,Premium, M340,
M580, M580S, Momentum Machine level

Unity Pro
PC

The diagnostics offer for Modicon M340, M580, M580S, Momentum, Premium and
5
Quantum platforms is based on the following three components:
bb System diagnostics
bb DFB and EFB diagnostic function blocks (for system and application diagnostics)
bb Error message display system, called viewers, supplied as a standard component
of Magelis terminal, Vijeo Citect supervisory software and Unity Pro setup software

6
System diagnostics
The system diagnostics for the Modicon M340, M580, M580S, Momentum, Premium
and Quantum platforms support the monitoring of system bits/words, I/O modules and
activity times (minimum/maximum) of SFC steps. By simply choosing the relevant
option during application configuration, any event will generate time-stamped
messages logged in the diagnostic buffer of the PAC.
These events are displayed automatically in a diagnostics viewer (1) without requiring 7
any additional programming.

With Unity Pro integrated diagnostics, this function can be used to perform first-level
diagnostics of the elements in the configuration, up to and including each I/O module
channel.

Configuration level
9
Module level

Viewer window (example with Unity Pro software) Channel level 10


(1) Diagnostics viewers are tools for displaying and acknowledging diagnostic error messages.
They are supplied as a standard component of Unity Pro and Vijeo Designer software, with
Magelis terminals and with the PLC Web server that can be accessed via a thin client
Magelis iPC.

1/13
Functions (continued) Software
Unity Pro software
Small/Large/Extra Large/Extra Large Safety

Modifying the program with the PAC in RUN mode


With Unity Pro, changes can be made to the program when the PAC connected to
1 the programming terminal is in RUN mode. These modifications are performed with
the following operations:
bb The application contained in the PAC is transferred to the PC terminal running
Unity Pro, if necessary.
bb Program changes are prepared. These program modifications can be of any type
and in any language (IL, ST, LD, FBD and SFC), for example, addition or deletion of
SFC steps or actions. The code of a DFB user function block can also be modified
2 (however, modification of its interface is not permitted).
bb These program changes are updated in the PAC (in RUN mode).

This function makes it possible to add or modify program code and data in different
parts of the application during a single modification session (thus resulting in a
uniform, consistent modification with respect to the controlled process). This
increased flexibility comes at a cost in terms of the amount of program memory
3 required.

Cross-references function
Unity Pro's cross-references function, which is available in standalone mode (offline)
and when connected to the PAC in Run (online), allows users to view the elements of
a PAC application when searching for any type of variable. This view indicates where

4 the declared variable is used, as well as how it is used (for writing, reading, etc.).
This function also provides access to the Search/Replace function for variable
names.
The variable search can be initialized from any editor (language, data, runtime
screen, animation table, etc.).
Cross-references table

5
Import/export function
The import/export function available in Unity Pro supports the following operations
from the structural and functional project views:

6
bb Via the import function, reuse of all or part of a previously created project in the
current project.
bb Via the export function, copying of all or part of the current project to a file for
subsequent reuse.

The files generated during export are generally in XML format (1). However, in
addition to XML, variables can be exported and imported in the following formats:
Data export shortcut menu bb .xvm format compatible with OFS data server software
7 bb source format, in an .scy file compatible with PL7 development software
bb text format with separator (TAB) in a .txt file for compatibility with any other system

During an import, a wizard can be used to reassign data to new instances of:
bb DFB function blocks
bb DDT data structures
bb simple data
8 In addition, when a functional module is imported, the data associated with
animation tables and runtime screens is also reassigned.

The XML import function also supports the transfer of a Modicon M340,


Modicon M580, Modicon M580 Safety, Premium or Quantum PAC configuration
prepared in the SIS Pro costing and configuration tool for use in the creation of a
project in Unity Pro. This import function spares the user from having to redefine the
9 Data import wizard
PAC configuration when the PAC has already been configured with the SIS Pro tool.

Unity Pro includes an Excel import/export tool that makes it easy to manage the
variables using an XML export file in Excel.

(1) XML language is an open, text-based language that provides structural and semantic
information.

10

Selection guide:
page 1/2

1/14
Functions (continued) Software
Unity Pro software
Small/Large/Extra Large/Extra Large Safety

Application converters
Unity Pro’s integrated conversion tools can be used to convert applications created
with ModSoft, ProWorX, Concept and PL7 programming software to Unity Pro
applications.
1
Concept/Unity Pro converter (Quantum and Momentum PACs)
This conversion is performed with a Concept application V2.5 or later (it can also be
performed in V2.11 or later, but only after an update to V2.5). In order to perform the
conversion, the application should be exported to an ASCII file in Concept.
The export file is converted to a Unity Pro source file automatically. This file is then 2
analyzed by Unity Pro. At the end of the procedure, a conversion report is generated
and an output window displays any conversion detected error and provides direct
access to the part of the program to be modified.
The Concept application converter converts the application to Unity Pro, but does
not guarantee that it will operate correctly in real time. It is therefore essential to test
or debug all converted applications.
3
PL7/Unity Pro converter (Premium PAC and Atrium slot PAC)
This conversion is performed with a PL7 application V4 or later (Premium PAC or
Atrium slot PAC). In order to perform the conversion, the source file (complete
application or user function block) should be exported to PL7.
The conversion procedure is similar to that of the Concept conversion described
above.
Note: Applications created with Concept, Modsoft and ProWORX can be converted to LL984.
4
Please contact our Customer Care Center

Unity M580 Application Converter (UMAC)


The conversion from Unity Quantum and Unity Premium applications to Unity M580
applications is performed with UMAC.
UMAC is a standalone software tool that can be installed on a Windows PC. The
complete conversion process relies on the use of Unity Pro.
5
UMAC is available in 2 sizes: Lite and Standard. UMAC Lite is free and downloadable
from our website www.schneider-electric.com. UMAC Lite allows to retain the existing
configuration while UMAC Standard adapts the code to Modicon M580.
Unity M580 Application Converter tool
Operating system update utilities 6
The OS-Loader software is designed for updating operating systems on Premium
and Quantum platforms. It is supplied with Unity Pro software.
It is used to upgrade Unity processors and modules as well as to upgrade PL7 or
Concept processors and modules to make them compatible with Unity Pro.

OS-Loader software supports:


bb Premium processors
7
bb Quantum processors
bb Ethernet communication modules
bb EtherNet/IP communication modules

The operating system updates are performed as follows:


bb Uni-Telway RS 485 terminal link for Premium processors
bb Modbus or Modbus Plus terminal link for Quantum processors
8
bb Ethernet TCP/IP network for integrated Ethernet port on Premium processors and
Premium and Quantum Ethernet modules
Note: For Modicon M340, M580 and Momentum this service is provided by Unity Loader (see
page 2/6).

Online modification of the configuration (CCOTF)


This function, also called Change Configuration On The Fly (CCOTF), is used to modify
9
the Modicon M580 or Modicon Quantum configuration online (application in RUN mode):
bb Addition or removal of discrete or analog I/O modules
bb Modification of configuration parameters of discrete or analog I/O modules
(already present or newly installed)

On Quantum, the CCOTF function is supported by standalone processors for the


three types of I/O architecture (local, RIO, DIO) using version 5 of Unity Pro, and for 10
Hot Standby processors using version 4.1 or higher of Unity Pro.

The CCOTF function should first be validated in the Unity Pro configuration screen.
Configuration screen A confirmation screen appears when the configuration has been modified online.

1/15
Functions (continued) Software
Unity Pro software
Small/Large/Extra Large/Extra Large Safety
Programmable process control

Process control in machines


Unity Pro contains CONT_CTL, a library of 36 function blocks used to create control
1 loops for machine control.

The requirements for closed loop control functions in machines are adequately met
by Modicon M340, Modicon M580, Modicon M580 Safety, Modicon Momentum,
Premium and Quantum platforms thanks to the wealth of functions in the library and
the flexibility with which function blocks can be linked together through programming.
This solution therefore avoids the need for external controllers and simplifies the
2 overall control architecture of the machine, as well as its design, roll-out and
operation.

The EFs or EFBs can be used in any of the Unity Pro languages (LD, ST, IL and
FBD). FBD is particularly suitable for accessing control processing operations in
Unity Pro through its wizard for entering and viewing parameters and function block
CONT_CTL, programmable process control integrated in
variables.
3
Unity Pro

CONT_CTL library functions


The library consists of six function families:
bb input data conditioning
bb controllers
bb mathematical functions

4
bb process value processing
bb output value processing
bb setpoint management

Input data conditioning


DTIME Pure time delay
INTEGRATOR Integrator with limiting

5 LAG_FILTER First order time lag


LDLG Lead/lag function with smoothing
LEAD Lead function with smoothing
MFLOW Mass flow calculation based on the measurement of differential
pressure or flow speed with pressure and temperature
compensation
QDTIME Dead time term
SCALING Scaling
6 TOTALIZER Integrator (typically of flow) until a limit (typically a volume) is
reached, with automatic reset
VEL_LIM Velocity limiter, with manipulated variable limiting

AUTOTUNE PIDFF
TT18_PV PV OUTD
Controllers
PV_O PV
TT18_SP SP SP_O SP PI_B Basic PI controller: PI algorithm with a mixed structure
TC18_OUT RCPY PARA_C TC18_PARA FF
TC18_START START (series/parallel)

7
TC18_OUT RCPY
TC18_PREV PREV MAN_AUTO MA_O
TC_PARA PARA
1
PARA INFO
PIDFF Complete PID controller: PID algorithm with a parallel or mixed
TR_I TRI TR_I STATUT structure (series/parallel)
TR_S TRS TR_S
INFO TC2_OUT OUT OUT TC2_OUT AUTOTUNE Automatic tuner setting for the PIDFF (complete PID) controller or
STATUS the PI_B (simple PI) controller
MS v Identification using Ziegler Nichols type method
TC2_OUT IN v Modeling based on first-order process
FORC
MA_FORC v Building of control parameters with criterion for prioritizing
MAN_AUTO OUTD either the reaction time to disturbance (dynamic) or the stability

8
PARA
TR_I
MA_O
STATUT
of the process
TC18_OUT
TR_S
OUT OUT TC18_OUT
IMC Model-based controller. The model is a first-order model with
delay. This corrector is useful:
Example: PID controller with MS manual control v When there are serious delays compared with the main time
constant of the process; this scenario cannot be satisfactorily
resolved by standard PID process control.
v For regulating a non-linear process IMC can handle any stable
aperiodic process of any order.

9 SAMPLETM Control of controller startup and sampling


STEP2 Simple two-position controller
STEP3 Three-position controller for temperature regulation

Mathematical functions
COMP_DB Comparison of two values, with dead zone and hysteresis

10
K_SQRT Square root, with weighting and threshold, useful for linearization
of flow measurements
MULDIV_W Weighted multiplication/division of 3 numerical values
SUM_W Weighted summing of 3 numerical values

Selection guide:
page 1/2

1/16
Functions (continued), Software
Unity Pro software
Small/Large/Extra Large/Extra Large Safety
Programmable process control

Process control in machines (continued)


CONT_CTL library functions (continued)
Process value processing 1
AVGMV Moving average with fixed number of samples (50 max.)
AVGMV_K Moving average with constant correction factor, 10,000 samples
max.
DEAD_ZONE Dead zone
LOOKUP_TABLE1 Linearization of characteristic curves using first-order interpolation

SAH
HYST_XXX
Detection of a rising edge
Detection of high threshold with hysteresis (1)
2
INDLIM_XXX Detection of high and low thresholds with hysteresis (1)

Output value processing


MS Manual control of an output
Programming in Unity Pro in offline mode MS_DB Manual control of an output with dead zone
PWM1
SERVO
Control via pulse width modulation
Control for servo motors
3
SPLRG Control of two Split Range actuators
Setpoint management
RAMP Ramp generator, with separate ascending and descending ramps

RATIO
SP_SEL
Ratio controller
Selection of setpoint value: local (operator) or remote (processing) 4

Setting up process control function blocks


Based on the sequencing of function blocks, the FBD language integrated in Unity

5
Pro is a programming language particularly suitable for building control loops.
Designers can use FBD to easily associate blocks from the CONT_CTL library with
their own DFBs written in Unity Pro’s ST, IL or LD language, or in C language.

Debugging, operation
All Unity Pro’s standard debugging services (see page 1/11) are available. In
particular, the PLC simulator can be used to check correct execution of processing
offline. 6
Compatibility
The CONT_CTL control function block library is available in all versions of Unity Pro.
It is compatible with processors in the Modicon M340, Modicon M580,
Modicon M580 Safety, Modicon Momentum, Premium and Quantum ranges.
7
Optional specialized libraries
The CONT_CTL control function block library can be supplemented with optional
specialized libraries, to meet specific needs such as predictive control, fuzzy logic
Programming in online mode
controller, HVAC and mass flow calculation (see page 2/8).
8
Resources
The technical documentation provides many examples of how to set up
programmable process control function blocks in FBD, LD, IL and ST languages.

The techniques for adjusting process control loops are described in the document
“Process control, Unity V3.0” available online at www.schneider-electric.com.
9
(1) XXX according to the type of variable: DINT, INT, UINT, UDINT, REAL.

10

Selection guide:
page 1/2

1/17
Functions (continued) Software
Unity Pro software
Small/Large/Extra Large/Extra Large Safety

Communication drivers
The most commonly used communication drivers for Modicon M340, M580, M580S,
1 Momentum, Premium and Quantum platforms are installed at the same time as the
Unity Pro software.

Unity Pro also includes the following drivers, which can be installed as required (1):
Protocol - Hardware Windows® 7 Windows® 10
32-bit and 64-bit editions 32-bit and 64-bit editions

2 Fip adaptor - CUSBFIP


Modbus Serial - COM port
PCIway - Atrium TPCI57 PCI card
Uni-Telway - COM port
USB for high end PLC
XIP - XWay on TCP/IP

3 Driver available Driver not available

Upgrade kits for Concept, PL7 Pro and ProWORX software


The Concept, PL7 Pro and ProWORX upgrade kits allow users who already have
one of these programs from the installed base, and who have a current subscription,
4 to obtain Unity Pro version V4.1 software at a reduced price.

These upgrades are only available for licenses of the same type (e.g. from Concept
XL group license to Unity Pro Extra Large group license).

Composition and Windows® OS compatibility


5 Unity Pro multilingual software packages are compatible with Windows 7
Professional (32-bit and 64-bit), Windows 10 (32-bit and 64-bit) and Windows
Server 2012 R2 operating systems. On 64-bit Windows 7, the installation of Service
Pack 1 (SP1) is mandatory in order to use Unity Pro V13. A 64-bit Windows
operating system with 4 GB RAM minimum is recommended for projects using
DTMs.

6 Note: Unity Pro requires .NET Framework 3.5 and .NET Framework 4.5.2.

They include:
bb Documentation in electronic format in six languages (English, French, German,
Italian, Spanish and Chinese)
bb Converters for converting applications created with Concept, PL7 and Unity M580
application converter (UMAC) programming software
7 bb PLC simulator
Cables for connecting the processor to the programming PC need to be ordered
separately.

(1) Also available separately under reference TLXCDDRV20M.

10

Selection guide:
page 1/2

1/18
Functions (continued) Software
Unity Pro software
Small/Large/Extra Large/Extra Large Safety

Unity Pro update


Customers are notified automatically when a new Unity Pro update becomes
available.
They can then access the software update manager directly, download the update
1
and install it locally on their workstation.

Note: The latest firmware versions can be downloaded from our website
www.schneider-electric.com. 5

10

Selection guide:
page 1/2

1/19
References Software
Unity Pro software
Small/Large/Extra Large/Extra Large Safety

Unity Pro version 13 software


Unity Pro software packages
1 These software packages are for programming and setting up Unity automation
platforms. The software is available in three versions:
bb Unity Pro Small (see page 1/21)
Unity Pro bb Unity Pro Large (see page 1/22)
bb Unity Pro Extra Large (see page 1/23)
bb Unity Pro Extra Large Safety (see page 1/24)

2 Upgrade kits for Concept, PL7 Pro and ProWORX software


These upgrade kits allow users who already have these software programs from the
installed base and who have a current subscription to obtain Unity Pro version
V13 software at a reduced price. These upgrades are only available for licenses of
the same type (e.g. from Concept XL group license to Unity Pro Extra Large group
license). See page 1/23.
3 Subscription renewal of Unity Pro software packages
If the user renews the subscription support before the end of renewal date:
bb The new subscription period starts automatically at the end of the previous one.
bb New versions of the software are sent to the customer during the subscription
period.

4 Expired subscription renewal of Unity Pro software packages (1)


If the user renews the subscription after the end of the renewal date:
bb The latest version of the software is sent to the customer.
bb The customer must register within three months for the new subscription period.
bb The new subscription period starts at the time of registration.
bb New versions of the software are sent to the customer during the subscription

5
period.
bb There is no subscription support during the time elapsed between the two
periods.

Composition and Windows OS compatibility


Unity Pro multilingual software packages are compatible with Windows 7 (32-bit and
64-bit), Windows 10 (32-bit and 64-bit) and Windows Server 2012 R2 operating

6 systems.

The packages comprise:


bb A Unity Pro V13 DVD in six languages (English, French, German, Italian,
Spanish and Chinese)
bb An Advantys V11 minimum configuration software CD
bb A one-year service subscription

7 (1) Automatic renewals for Unity Pro new versions are possible during the first year of
subscription. Please contact our Customer Care Center for more information.

10

Selection guide: References:


page 1/2 page 1/21

1/20
References (continued) Software
Unity Pro software
Small

Unity Pro Small version 13 software


For Modicon M340: All models
For Modicon Momentum: 171CBU78090/98090/98091
For distributed I/O: Modicon ETB, TM7, OTB, STB, Momentum 1
Unity Pro Small version 13 software packages (1) (2)
Description License type Reference Weight
kg/lb
Unity Pro Small Single (1 station) UNYSPUSFUV1X –
software packages
Group (3 stations) UNYSPUSFGV1X – 2
Team (10 stations) UNYSPUSFTV1X –

Software upgrades from: Single (1 station) UNYSPUSZUV1X –


- Concept S
- PL7 Micro Group (3 stations) UNYSPUSZGV1X –
- ProWORX NxT/32 Lite
Team (10 stations) UNYSPUSZTV1X –

License type extensions for Unity Pro Small version 13


3
From To Reference Weight
kg/lb
Single (1 station) Group (3 stations) UNYSPUSZUGV1X –

Group (3 stations) Team (10 stations) UNYSPUSZGTV1X –

(1) For compatibility of Unity software/automation platforms and distributed I/O, refer to the
4
selection guide on page 1/2.
(2) Automatic renewals for Unity Pro new versions are possible during the first year of
subscription. Please contact our Customer Care Center for more information.

10

1/21
References (continued) Software
Unity Pro software
Large

Unity Pro Large version 13 software


For Modicon M340: All models
1 For Modicon M580: BMEH5820/BMEP5810/5820/5830
For Modicon Momentum: 171CBU78090/98090/98091
For Modicon Premium: TSX571p…4p
For Modicon Quantum: 140CPU31110/43412U/53414U
For distributed I/O: Modicon ETB, TM7, OTB, STB, Momentum
Unity Pro
Unity Pro Large version 13 software packages (1) (2)

2
Description License type Reference Weight
kg/lb
Unity Pro Large Single (1 station) UNYSPULFUV1X –
software packages
Group (3 stations) UNYSPULFGV1X –

Team (10 stations) UNYSPULFTV1X –

Facility (y 100 stations) UNYSPULFFV1X –

3 Software upgrades from:


- Concept S, M
Single (1 station) UNYSPULZUV1X –

- PL7 Micro, Junior, Pro Group (3 stations) UNYSPULZGV1X –


- ProWORX NxT/32 Lite
Team (10 stations) UNYSPULZTV1X –

Facility (y 100 stations) UNYSPULZFV1X –

4 License type extensions for Unity Pro Large version 13


From To Reference Weight
kg/lb
Single (1 station) Group (3 stations) UNYSPULZUGV1X –

Group (3 stations) Team (10 stations) UNYSPULZGTV1X –

5
Upgrade to Unity Pro Large from Unity Pro Small
Type of upgrade Reference Weight
The number of stations is unchanged kg/lb
Small to Large Single (1 station) UNYSPULZSUV1X –

Small to Large Group (3 stations) UNYSPULZSGV1X –

Small to Large Team (10 stations) UNYSPULZSTV1X –

6 Upgrade to Unity Pro Large from Unity Pro Medium


Type of upgrade Reference Weight
The number of stations is kg/lb
unchanged
Small to Large Single (1 station) UNYSPULZMUV1X –

Small to Large Group (3 stations) UNYSPULZMGV1X –


7 Small to Large Team (10 stations) UNYSPULZMTV1X –

(1) For compatibility of Unity software/automation platforms and distributed I/O, refer to the
selection guide on page 1/2.
(2) Automatic renewals for Unity Pro new versions are possible during the first year of
subscription. Please contact our Customer Care Center for more information.

10

1/22
References (continued) Software
Unity Pro software
Extra Large

Unity Pro Extra Large version 13 software


For Modicon M340: All models
For Modicon M580: All models
For Modicon Momentum: 171CBU78090/98090/98091 1
For Modicon Premium: TSX571p...6p
For Modicon Quantum: 140CPU31110/43412U/53414U/65150/65160/65260/67160/67260/67261
For distributed I/O: Modicon ETB, TM7, OTB, STB, Momentum

Unity Pro Extra Large version 13 software packages (1) (2)

2
Description License type Reference Weight
kg/lb
Unity Pro Extra Large Single (1 station) UNYSPUEFUV1X –
software packages
Group (3 stations) UNYSPUEFGV1X –

Team (10 stations) UNYSPUEFTV1X –

Facility (y 100 stations) UNYSPUEFFV1X –

Software upgrades from:


- Concept S, XL
Single (1 station) UNYSPUEZUV1X –
3
- PL7 Micro, Junior, Pro Group (3 stations) UNYSPUEZGV1X –
- ProWORX NxT Lite, Full
Team (10 stations) UNYSPUEZTV1X –
- ProWORX 32 Lite, Full
Facility (y 100 stations) UNYSPUEZFV1X –

License type extensions for Unity Pro Extra Large


From To Reference Weight
4
kg/lb
Single (1 station) Group (3 stations) UNYSPUEZUGV1X –

Group (3 stations) Team (10 stations) UNYSPUEZGTV1X –

5
Upgrade to Unity Pro Extra Large from Unity Pro Large
Type of upgrade Reference Weight
The number of stations is unchanged kg/lb
Large to Pro Extra Large Single (1 station) UNYSPUEZLUV1X –

Large to Pro Extra Large Group (3 stations) UNYSPUEZLGV1X –

Large to Pro Extra Large Team (10 stations) UNYSPUEZLTV1X –

Unity Pro Extra Large Educational version 13 software packages (1) (2) 6
Description License type Reference Weight
kg/lb
Unity Pro Educational Facility (y 100 stations) UNYSPUEEFV1X –
software package
(1) For compatibility of Unity software/automation platforms and distributed I/O, refer to Unity
Pro Extra Large in the selection guide on page 1/3.
(2) Automatic renewals for Unity Pro new versions are possible during the first year of
subscription. Please contact our Customer Care Center for more information.
7

10

1/23
References (continued) Software
Unity Pro software
Extra Large Safety

Unity Pro Extra Large Safety software


For Modicon M340: All models
1 For Modicon M580: All models
For Modicon M580 Safety : All models
For Modicon Momentum: 171CBU78090/98090/98091
For Modicon Premium: TSX571p...6p
For Modicon Quantum: 140CPU31110/43412U/53414U/65150/65160/65260/67160/67260/67261
Unity Pro For distributed I/O: Modicon ETB, TM7, OTB, STB, Momentum

Unity Pro Extra Large safety software packages (1) (2)


2 Description License type Reference Weight
kg/lb
Unity Pro Extra Large Single (1 station) UNYSPUXFUV1X –
software packages
Group (3 stations) UNYSPUXFGV1X –

Team (10 stations) UNYSPUXFTV1X –

3
Facility (≤ 100 stations) UNYSPUXFFV1X –

License type extensions for Unity Pro Extra Large Safety


From To Reference Weight
kg/lb
Single (1 station) Group (3 stations) UNYSPUXZUGV1X –

Group (3 stations) Team (10 stations) UNYSPUXZGTV1X –


4 Team (10 stations) Facility (≤ 100 stations) UNYSPUXZTFV1X –

Upgrade to Unity Pro Extra Large Safety from Unity Pro Large
Type of upgrade Reference Weight
The number of stations is unchanged kg/lb
Large to Pro Extra Large Safety Single (1 station) UNYSPUXZEUV1X –

5 Large to Pro Extra Large Safety Group (3 stations) UNYSPUXZEGV1X –

Large to Pro Extra Large Safety Team (10 stations) UNYSPUXZETV1X –

Large to Pro Extra Large Safety Facility (≤ 100 stations) UNYSPUXZEFV1X –

Unity Pro Extra Large Educational software packages (1) (2)

6 Description License type Reference Weight


kg/lb
Unity Pro Educational Facility (≤ 100 stations) UNYSPUXEFV1X –
software package

(1) For compatibility of Unity software/automation platforms and distributed I/O, refer to Unity
Pro Extra Large in the selection guide on page 1/3.
(2) Automatic renewals for Unity Pro new versions are possible during the first year of

7 subscription. Please contact our Customer Care Center for more information.

10

1/24
References (continued) Software
Unity Pro software
Small/Large/Extra Large/Extra Large Safety

Accessories for connecting to the PC programming terminal


Description Use Length Reference Weight
From processor port To PC port m/ft kg/lb
1
PC terminal USB mini B port USB port 1.8/ BMXXCAUSBH018 0.065/
connection BMXP341000/20p0/20p02 5.91 0.143
cables BMEP58pppp 4.5/ BMXXCAUSBH045 0.110/
(PC to PAC) 14.8 0.243
BMXXCAUSBH0pp
(1)
Mini-DIN port RS 232D 2.5/ TSXPCX1031 0.170/
Premium TSX571p/2p/3p/4p (9-way 8.20 0.375
SUB-D
connector) 2
USB port 0.4/ TSXCUSB485 0.144/
(USB/ 1.31 (2) 0.318
RS 485
converter)
USB port 2.5/ TSXCRJMD25 0.150/

3
(mini-DIN/ 8.20 (2) 0.331
RJ45
TSXPCX1031 cordset)
Modbus port RS 232D 3.7/ 990NAA26320 0.300/
15-way SUB-D Quantum (9-way 12.1 0.661
140CPU31110 SUB-D 15/ 990NAA26350 0.180/
140CPU43412A connector) 49.2 0.397
140CPU53414B

USB port
Premium TSX575p/6p
USB port 3.3/
10.8
UNYXCAUSB033 –
4
Quantum 140CPU6p1
Modbus port, RJ45 connector RJ 45 1/ 110XCA28201 –
Quantum 140CPU6p1 connector 3.28
3/ 110XCA28202 –
TSXCUSB485 9.84
6/
19.7
110XCA28203 – 5
PC terminal HE13 connector Modicon RS 232D 2/ STBXCA4002 0.210/
connection STB I/O network interface (3) 6.56 0.463
cables module (NIM) (9-way
(PC SUB-D SUB-D
to connector)
Modicon STB
I/O)
6
USB/SUB-D HE13 connector Modicon USB port – SR2CBL06 0.185/
adaptor STB I/O network interface (4) 0.408
(PC USB to module (NIM) with
Modicon STB STBXCA4002 cable (4)
I/O)

Description Use Reference Weight


kg/lb
7
Universal Provides Bluetooth® connectivity for products TCSWAAC13FB 0.320/
Bluetooth® such as the Modicon M340/Premium platforms 0.705
interface and Altivar/Lexium servo drives, via their serial port
(UBI) (RS 485).
Used for setup and maintenance of products.

8
Designed for permanent installation and can be
TCSWAAC13FB fitted on the inside or outside of electrical
enclosures.
bb Protocols supported: Modbus and Uni-Telway
bb Powered via the product’s RS 485 serial port
bb Max. range in direct line of sight: 20 m/65.6 ft

The kit comprises:


bb A Universal Bluetooth® interface (UBI)
bb An RJ45/mini-DIN cable (length 1 m/3.28 ft)
bb An RJ45/RJ45 cable (length 1 m/3.28 ft)
bb A fixing clamp for installation inside the electrical
9
enclosure
bb A CD with configuration software and user
manual
(1) The 490NTW00002 and 490NTW00002U RJ45 ConneXium cables (2 m/6.56 ft) can be used
to connect the PC to the SERVICE port of M580 CPUs or X80 drop. Please consult our
website www.schneider-electric.com.
(2) The TSXCUSB485 converter requires use of the TSXCRJMD25 mini-DIN/RJ45 cordset.
(3) Use the SR2CBL06 cable for connection on a USB port (4).
10
(4) Adapter equipped with a USB connector (PC side) and a 9-way SUB-D connector
(STBXCA4002 cable side); requires the STBXCA4002 cable (9-way SUB-D/HE 13) for
connection to the HE13 connector on the Modicon STB NIM.

1/25
1

10

2/0
Contents 2 - Companion software

Unity EFB Toolkit software


bb Presentation, setup................................................................................ page 2/2
bb References.............................................................................................. page 2/3 1
Unity DIF software
bb Presentation, setup................................................................................ page 2/4
bb References.............................................................................................. page 2/5

Unity Loader software


bb Presentation............................................................................................ page 2/6 2
bb References.............................................................................................. page 2/7

Unity Specific libraries


bb Presentation............................................................................................ page 2/8
bb References.............................................................................................. page 2/9
3

10

2/1
Presentation, Software
setup Unity Pro software
Unity EFB Toolkit software

Presentation
Unity EFB Toolkit software helps to develop EFs and EFBs in “C” programming
1 language. As an option with Unity Pro, it can be used to extend the standard Unity
Pro function blocks in order to increase functionality. This software comes with
Microsoft Visual Studio, which can be used to debug the function blocks developed
in the Unity Pro PLC simulator. Unity EFB Toolkit also includes a service for creating
Unity EFB Toolkit and managing families of function blocks and integrating them in Unity Pro.

Setup
2 Unity EFB Toolkit manages the whole process of developing Unity Pro function
blocks:
bb User-friendly graphical user interface with automatic file organization
bb Powerful tools for testing and debugging
bb Management of compatibilities and software versions of created functions
bb Generation of executable files for subsequent installation of functions on different

3
Unity Pro stations

Managing function block families


EFB Toolkit helps to create and manage function block families. The function blocks
developed, also known as EFs/EFBs, are stored in families. It makes it possible to
create an organized library of functions written in “C” language. Once created, these
function block families are installed on the Unity Pro stations for the purpose of

4 extending the standard Unity Pro libraries. Integration in Unity Pro can be executed
from Unity EFB Toolkit or via the tool for updating Unity Pro libraries, which allows
these families to be distributed without the use of any other software.

Developing function blocks


The EFB Toolkit software allows the user to create a function block as follows:
bb Declaration of the function block interface in the same way as for the DFBs in
5 Unity Pro
bb Definition of all data types needed (elementary, structures, tables)
bb Support of public and private variables
EFB Toolkit: Managing function block families bb Generation of all files and the block “C” coding frame (the user only adds
functionality to this frame)
bb Granting access to numerous internal PAC services, such as the real-time clock,
PAC variables and data, system words and math functions, including high-precision

6 numerical processing in “double” format


bb Structure of the function block family (compilation/link for all Unity Pro automation
platforms)
bb Provision of a debugging environment: the function blocks created can easily be
debugged in Microsoft Visual Studio by downloading a Unity Pro application
containing the function developed in the Unity Pro PLC simulator. The debugging
functions in Microsoft Visual Studio, especially breakpoints, step-by-step operations,

7 display of the code/data and manipulation of the data, can be accessed without
restriction.
bb Support for managing Unity Pro versions, important during the function block
maintenance phase

Compatibility
Unity EFB Toolkit is compatible with Unity Pro Medium, Large and Extra Large. EFs

8 and EFBs can be developed for Modicon Premium, Quantum, M340, M580 and
Unity Momentum platforms.

The latest available EFB Toolkit version is V8.0:


bb OS compatibility Windows® 7 (32-bit and 64-bit), Windows® 8.1 (32-bit and 64-bit)
and Windows® Server 2008 (64-bit).
bb Minimum supported version of Unity Pro is V6.0 and above if installation is on the

9 same system.
bb The generated libraries can be installed on lower Unity Pro versions on different
EFB Toolkit: Editor systems.

10

2/2
References Software
Unity Pro software
Unity EFB Toolkit software

References
Unity EFB Toolkit and its documentation are supplied in electronic format on
DVD-ROM in English. 1
EFB Toolkit package includes:
bb Unity EFB Toolkit DVD
bb GNU Compiler CD
bb Microsoft Visual Studio DVD

Description Type Language Reference Weight


kg/lb
2
Unity EFB Toolkit Single license English (software and UNYSPUZFUCD80 –
software (1 station) electronic documentation)

10

2/3
Presentation, Software
setup Unity Pro software
Unity DIF software

Presentation

1
Unity DIF software helps to compare two Unity Pro application files and represents
differences in a graphical format similar to Unity Pro graphics for consistency and
better understanding. The differences are displayed graphically and textually based
on the type of section chosen. Unity DIF improves productivity during the main life
Unity DIF stages of a control system, mainly during development and debugging of
applications and commissioning, operation and maintenance of the installation.

Setup
2 Unity DIF compares two Unity Pro application files (XEF, ZEF, STU and STA) and
detects anything ADDED, DELETED and MODIFIED. The user interface and
graphical representation of differences are similar to Unity Pro for consistency and
ease of understanding the differences.

Unity DIF can be launched in several ways:

3 bb From Unity Pro


bb From the Windows Start menu
bb From a command line interface

Unity DIF can provide differences for the following sections:


bb PAC Configuration (Hardware and Network)

4
bb Derived Data Types
bb Derived FB Types
bb Variables and FB Instance
bb Motion
bb Communication
bb Programs
bb Animation Table

5
bb Operator Screen
bb DTM Catalog
Selection of elements to compare bb Project Settings

The result of the comparison can be printed or saved in .pdf and .txt file formats.

Windows® OS Compatibility

6 Unity DIF is compatible with Windows 7 (32-bit and 64-bit), Windows 10 (32-bit and
64-bit) and Windows Server 2008 R2 (64-bit).

Comparison (1)
The base and compare files have to be selected by the user, and the results of the
comparison will be displayed with respect to the base file as reference.

7
Before initiating comparison, the user can select his preference of required section
for comparison.

Displaying results
Upon comparison, the section summary will be loaded with the complete list of differences.
The user can navigate through the project browser window or using the F7 and F8 keys.
The differences will be highlighted in three different colors signifying Added, Deleted or
8 Modified types. Colors can be customized as per the user’s preference. The detailed report
can be generated through Print or can be Saved for later reference.
Unity DIF also supports command line processing and .txt report generation for interfacing
with Partner software.

Displaying results (1) Comparison of STU and STA requires Unity Pro to be available.

10

2/4
References Software
Unity Pro software
Unity DIF software

References
Unity DIF software is free and downloadable from our website:
www.schneider-electric.com. 1
Compatibility: Unity Pro V2.1 or later.
Description Language Type Reference Weight
kg/lb
Unity DIF software English (software Single UNYDFFXZZSPA80 –
and electronic
documentation)
license
(1 station)
(1)
2
(1) Available on our website www.schneider-electric.com.

10

2/5
Presentation Software
Unity Pro software
Unity Loader software

Presentation
Unity Loader is companion software to Unity Pro and is used to perform maintenance
1 operations on automation applications. Its easy setup and the small size of its
executable make it a vital tool for updating Unity Pro projects without needing to use
Unity Pro. It can also be used for updating the embedded software on Modicon
M340, M580, M580S or Momentum Unity PACs or on Modicon X80 I/O modules. It
Unity Loader performs the following main functions:
bb Transferring automation project components, such as the program and data, from
the PC to the PAC or the PAC to the PC
2 bb Transferring files and user Web pages stored in the memory card of Modicon
M340 PACs
bb Transferring the firmware from the PC to Modicon M340, M580, M580S or
Momentum Unity PACs or to Modicon X80 I/O modules

Software graphic interface


3 The interface is easy to use and has four tabs for access to different operations:
bb The “Project” tab manages the transfer of projects (program and data) between
the PC and the PAC CPU. The software transfers the program (application file
format: .stu; archive file format: .sta) and data (located and unlocated; data file
format: .dat) of a Unity Pro project in both directions. The program and data files
created by Unity Loader are compatible with Unity Pro. When it is connected to the

4
PAC, Unity Loader displays the information associated with the data read in the PAC.
This information is displayed on the PC for the selected files. The user decides which
project elements will be transferred by a single command after validation of the
required transfers.
vv Modicon M340 PACs and BMXRMSpp8MFP memory card only: the files and user
Web pages can be transferred from the memory card to the PC and vice versa.
Unity Loader: Project tab vv BMXNOE0110 with flash memory card only: Web pages stored in the flash

5
memory can be transferred from the module to the PC and vice versa.
bb The “Firmware” tab can be used to update the firmware in the Modicon M340,
M580, M580S or Momentum Unity PACs or on Modicon X80 I/O modules. The
screen displays the detailed content of the firmware versions existing in the module
and on the PC. Firmware updating works in the same way as project transfers.
bb The “Options” tabs is used to configure the working environment, especially the
location of files on the PC and the selection of one of the six languages supported
(English, French, German, Italian, Spanish and Chinese) for the user interface and
6 online help.
bb The “About…” tab displays information about the software.

Note: Regardless of which tab is selected, the connection status with the PAC is continuously
displayed, together with commands for connection/disconnection and changing the PAC
operating mode.

7 Modicon M340 PAC and BMXRMSpp8MFP memory card only


The Unity Loader software can download the project files and the firmware
(controller or module) onto a flash memory card (BMXRMSpp8MFP only) plugged
into the PAC CPU.
This firmware download can then be used to update a remote Modicon M340 PAC.

8
Automation of Unity Loader commands
Projects can be downloaded/uploaded between a PAC and a supervisory station
equipped with Unity Loader software by means of a command file included in the
supervisory application.

9 Unity Loader: Firmware tab

10

2/6
Presentation (continued), Software
references Unity Pro software
Unity Loader software

Communication between the PC and the PAC


Unity Loader supports the following PC-to-PAC communication:
bb Modicon Quantum Unity Pro PACs: Modbus communication, transfer of project
components only
1
bb Modicon Premium Unity Pro PACs: Unitelway communication, transfer of project
components only
Unity Loader bb Modicon M340, M580 or Momentum Unity PACs or Modicon X80 I/O modules:
communication via Ethernet and USB ports, transfer of project components and
firmware. See the table below:

Reference Type of module Ethernet port USB port


2
BMXP342000 M340 CPU with Modbus
BMXP342010/20103 M340 CPU with CANopen
BMXP342020 M340 CPU with integrated
BMXP342030/20302 Ethernet port

3
BMXNOE0100/0110 X80 module Ethernet
Modbus/TCP
BMXAMI/ART/AMO/AMM X80 module Analog I/O
BMXEHC0200/0800 X80 module Counter
BMXMSP0200 X80 module Motion
control
BMEP58 M580 CPUs

4
10XX/20XX/30XX/40XX
BMENOC03p1 M580 communication
module
171CBU78090 Momentum Unity CPU
with integrated port
171CBU98090/ Momentum Unity CPU
171CBU98091 with integrated port

Supported Supported if CPU has integrated Ethernet port 5


For Ethernet networks, Unity Loader contains a network scanner which can be used
to scan a range of network addresses. Once a recognized Modicon M340, M580 or
Momentum Unity PAC has been selected, data transfer operations can be
performed.

References 6
Unity Loader is supplied with Unity Pro Small, Large and Extra Large.
It can also be downloaded free of charge from our website
www.schneider-electric.com, download section.

Compatibility
Unity Loader is independent of Unity Pro and compatible with Modicon M340, M580
or Momentum Unity PACs, Unity Pro Quantum PACs via Modbus and Unity Pro
7
Premium PAC via Unitelway. The program files and PAC data files are compatible
between Unity Pro and Unity Loader.

Description Type Reference Weight

Unity Loader software Single license Software can be downloaded


kg/lb

8
(1 station) free of charge from our website
www.schneider-electric.com

10

2/7
Presentation Software
Unity Pro software
Specific libraries

Presentation
The CONT_CTL process control function block library supplied with Unity Pro
1 software can be supplemented with optional specialized libraries so as to meet
specific needs such as:
bb Predictive control
bb Fuzzy logic controller
Unity specific Libraries bb HVAC
bb Mass flow calculation

2 Fuzzy Control Library


This library is used in particular in the water treatment field, for example for
controlling chlorine levels in fresh water pools or controlling water levels in high-level
reservoirs.

3 Flow Calculation Library


This library is used in the vertical Oil & Gas field, for measuring the gas flow in
compliance with the American Gas Association (AGA) standard. This version of the
library includes the AGA3, AGA7 and AGA8 function blocks.

4
TeSys Library
This library provides function blocks for TeSys T and TeSys U starter-controllers for
M340 and Premium platforms.
It includes function blocks and a help function for Unity Pro.

PCR Library for Unity Pro and Concept

5 This library is used for predictive control of process applications.


Originally developed for reactors, predictive control can be used in other industrial
sectors.
Schneider Electric’s Companion Unity & Libraries team works in partnership with the
French company Sherpa Engineering, who specialize in predictive control
consultancy services.

6 Heating Ventilation & Air Conditioning Library


This library is used in the HVAC field and deals with repetitive temperature control
and humidity problems using ventilation equipment.

System Library for Unity Pro

7 This library offers functional blocks that are derived from Devices and Process
Library but only has Unity Pro components (DFBs).
The Devices and Process Library supports several Schneider Electric devices
including TeSys T and TeSys U starters-controllers, Modicon STB distributed inputs/
outputs, power meters, Altivar variable speed drives, Icla and Lexium integrated
drives, SEPAM digital protection relays, various fieldbus communications and other
standard objects for motors.
8 There are approximately 100 objects in the library.

10

2/8
References Software
Unity Pro software
Specific libraries

Specific libraries depending on the software used


Specific libraries depending on the software used (see below) can be ordered
separately. 1
Control libraries
Unity specific Libraries Description Target Type Reference Weight
software kg/lb
PCR Library Unity Pro Single UNYLPCZAUWB –
and
Concept
license
(1 station) 2
Fuzzy Control Library Unity Pro Single UNYLFZZAUWB12 –
license
(1 station)
TeSys Library UNYLTSZAUWB10 –

3
Heating Ventilation & Air UNYLHVZAUWB10 –
Conditioning Library

Flow Calculation Library UNYLAGZAUWB20 –

GPL (General Purpose


Library) Version 2017
(1) (1) – 4
System libraries for Unity Pro
Description Target Type Reference Weight
software kg/lb

5
Enhanced Process Library (2) UAG Single UAGSBTCFUCD10 –
license
(1 station)
Devices and Process Library (2) UAGSBTDFUWB13 –

(1) PSx GPL Library is available for free.


(2) Compatible with Unity Pro V5.0 max. For Unity Pro u V6.0, please consult our Customer Care
Center.
6

10

2/9
1

10

3/0
Contents 3 - OPC data server software,
Product reference index

OPC data server software


bb Presentation............................................................................................ page 3/2
1
bb Architectures.......................................................................................... page 3/3
bb Setup....................................................................................................... page 3/5
bb Functions................................................................................................ page 3/6
bb References.............................................................................................. page 3/7 2
bb Time stamping system........................................................................... page 3/8
vv Presentation............................................................................................. page 3/8
vv Architectures............................................................................................ page 3/8
vv Performance............................................................................................. page 3/9

Product reference index 3


bb Product reference index....................................................................... page 3/10

10

3/1
Presentation 3
Software 3

OPC data server software


OPC Factory Server

Presentation
Based on the OLE for Process Control (OPC) standard, Schneider Electric's OPC
1 Factory Server (OFS) software allows “client” software applications, such as
supervisors/SCADA and customized interfaces, to access the data of Schneider
Electric automation system and electrical distribution devices connected to networks
OPC Factory Server or fieldbuses in real time.
It also allows communication with third-party devices supporting Modbus and
Modbus/TCP protocols.

2 OFS enables simpler, more open and transparent communication between your
software applications and your devices. These are just some of the advantages that
result in a complete interoperability solution that is central to your process.

In version V3.6, the OFS provides the following additional features:


bb OPC DA (OPC Data Access)
bb .NET API interface
3 bb Native support for a redundant link with the PAC
bb Access to time-stamped variables in the PAC or X80 drops
bb V3.6 is compatible with Wonderware WSP environment (OPC DA compatible
only). More details are available on the Wonderware Global Customer Support site

There are two versions of the OFS V3.6 offer supporting the OPC DA protocol:
bb OFS Small: Data server for 1,000 items (1).
4 bb OFS Large: Data server with an unlimited number of items (1).

Devices and protocols supported


OFS software is a multi-device data server: it allows simultaneous use of several
communication protocols, and it provides client applications with a set of services for
accessing control system items that may be local or remote, via physical address or
via symbol.
5 Devices supported:
bb Modicon Quantum, Premium, M340, M580, Micro, Compact and Momentum
PACs
bb Schneider Electric TSX Series 7 and April Series 1000 PACs
bb Modbus serial devices connected via Schneider Electric gateways: TSXETG10pp,
EGXppp ranges, etc.
6 bb Uni-Telway serial devices connected via Schneider Electric gateways
(TSXETG1010)
Networks and protocols supported:
bb Modbus: Modbus serial, Modbus Plus, Modbus/TCP
bb X-Way/Uni-TE: Uni-Telway, Fipway, ISAway, PCIway

Redundant link on Modbus/TCP


7 The OFS V3.6 incorporates native support for a redundant link with the PAC in order
to optimize system availability without any impact on the SCADA application. OFS
automatically changes over from the primary to the standby communication path in
case of a communication fault.

Openness
8 The development of specialized interfaces is simpler with OFS V3.6 software, which
is aimed at two types of user in particular:

bb End users who want either to interface their supervision or human/machine


interface applications with Schneider Electric equipment, or to develop applications
on a PC (supervisory control screens, Excel spreadsheets etc.) requiring access to
control system data.

9 bb Suppliers of control system or industrial data processing software


(supervision, human/machine interfaces, etc.) seeking to develop, within their
standard products, an OPC Client interface capable of accessing data in Schneider
Electric equipment via the OFS server.

(1) “item”: variable, structure, table etc. in the Unity Pro application.

10

3/2
Architectures  0
Software 3

OPC data server software


OPC Factory Server

Supported architectures
The OFS server allows four access modes:
bb A purely local mode
bb Remote access from an OPC DA client
1
bb Remote access from an OPC.NET client

Local access
The client application and the OFS server are on the same PC.

OFS station 2
Local client
applic. prog Symbol data
(Unity Pro,
Concept
OPC Factory Server: Home page or PL7)

3
Modbus network

M580 Premium M340


4
Quantum

Remote access from an OPC DA client


The client application and the OFS data server are on remote stations.
Communication between the client station and the OFS server is conducted through
5
the DCOM layer (Microsoft) via the OPC DA protocol.

Ethernet Modbus/TCP network


DCOM

Remote client
OFS station

Local client
6
application applic. prog Symbol data
program (Unity Pro ,
Concept
or PL7)

Modbus network X-Way network 7

8
Premium M340
M580

Quantum

10

Presentation: Setup: Functions: References: Time-stamping system:


page 3/2 page 3/5 page 3/6 page 3/7 page 3/8

3/3
Architectures (continued)  0
Software 3

OPC data server software


OPC Factory Server

Architectures supported (continued)


Remote access from an OPC .NET client
1 The .NET client application program and the OFS data server are on remote
stations. Communication between the client station and the OFS server is
conducted through the DCOM layer (Microsoft) via the OPC DA protocol.

Intranet

2 DCOM Ethernet Modbus/TCP network

.NET client Server


OFS station

The .NET Microsoft compatibility of the OFS server has been developed to allow an
OPC .NET client to access OFS server items on an Intranet network via the OPC
.NET API interface.
4 This interface provides interoperability between existing OPC applications and
applications developed in the standard .NET environment.

10

Presentation: Setup: Functions: References: Time-stamping system:


page 3/2 page 3/5 page 3/6 page 3/7 page 3/8

3/4
Setup 3
Software 3

OPC data server software


OPC Factory Server

Setup

Ethernet Modbus/TCP 1
1
OFS server
(V3.0) 4
Database Unity Pro
project
station
2
Symbols.xvm (Unity Pro)
Symbols.prj (Concept)
2 OPC client Symbols.scy (PL7)
3 Quantum

3
3 Premium
Ethernet Modbus/TCP

3 M580 3 M340 4
The OFS server 1 is at the center of the data exchanges. It makes variables
exchanged between the OPC client 2 and the PAC 3 consistent in one of three ways,
using a symbol (or variables) database:

bb The variables database is either the Unity Pro project 4, or the Concept project.
5
In both these cases, Unity Pro or Concept needs to be installed on the OFS server
station.

bb Or the variables database is an export file (SCY for PL7, XVM for Unity Pro). PL7
and Unity Pro are not required in either of these cases.

bb Or the variables database is the PAC itself. In this case neither Unity Pro nor an 6
export file is needed. This does not apply to Momentum and TSX Micro PACs. If an
inconsistency is detected (following online modification of the PAC program for
example), OFS resynchronizes itself automatically as a background task, without
breaking communication between the PAC and the OPC client.
For this function the following minimum versions are required:
vv OFS V3.35
vv Unity Pro V6.0 7
vv Modicon M340 V2.3, M580 V1.0, Premium V2.9 and Quantum V3.0 PACs

10

Presentation: Architectures: Functions: References: Time-stamping system:


page 3/2 page 3/3 page 3/6 page 3/7 page 3/8

3/5
Functions  3
Software 3

OPC data server software


OPC Factory Server

Function
Development of client applications
1 OFS software has 4 types of interface:

bb OLE Automation interface (OPC DA)


Particularly suitable for end users, this enables the development of OPC client
applications in Visual Basic, in Visual Basic for Excel, and in C++.

2
bb OLE Custom interface (OPC DA)
Used primarily by suppliers of automated control system or industrial IT products,
this interface enables the development of applications in C++ in order to access the
OFS software OPC server. It is aimed at software development experts in particular,
so that they can integrate the client application into their standard products. It is the
interface with the highest performance, in terms of access time to data stored in the
OPC server. It requires extensive knowledge of C++ programming to set up.

3 bb OPC .NET API wrapper interface


The .NET Microsoft compatibility of the OFS data server gives an OPC .NET client
standard access to OFS server items via an Intranet network, thus providing greater
interoperability with standard .NET environments.
Note: In this case, communication between the OPC .NET client and the OFS server is
conducted through the DCOM layer (or COM layer in a local configuration) via the OPC DA
protocol.
4

10

Presentation: Architectures: Setup: References: Time-stamping system:


page 3/2 page 3/3 page 3/5 page 3/7 page 3/8

3/6
References 3
Software 3

OPC data server software


OPC Factory Server

References
OFS V3.6 software for PC compatible stations (minimum configuration: Pentium
566 MHz processor, 128 MB of RAM) running Windows® 7 (32-bit or 64-bit) or
Windows 8 (32-bit or 64-bit).
1
OPC Factory Server The OFS V3.6 offer comprises:
bb OPC server software
bb OPC server simulator (for debugging the application when no PACs are present)
bb OFS server configuration software
bb An example of OPC client for setting up applications
bb The setup documentation on DVD-ROM
2
bb A reference document on “time stamping system” solutions
bb A tool to help with sizing and configuring “time stamping system” solutions

Supplied on DVD-ROM, the software operates independently on a PC. It interfaces


with the variable export files generated by PL7, ProWORX, Concept, and Unity Pro
software.
It also provides a direct dynamic link to the Unity Pro and Concept applications.
3
OFS V3.6 software is available in two versions :
bb Small Version TLXCDSpOFS36
vv Maximum of 1,000 items (1)
vv Protocol supported: OPC DA
vv Single station and 10-station site licenses
bb Large Version TLXCDLpOFS36
4
vv Unlimited number of items (1)
vv Protocol supported: OPC DA
vv Single station, 10-station and 200-station site licenses

OPC Factory Server V3.6 Small


Description License type Reference Weight
5
kg/lb
OPC Factory Server Single station TLXCDSUOFS36 –
V3.6 Small software 10 stations TLXCDSTOFS36 –
bb Maximum of 1000
items (1)
bb Protocols supported:
OPC DA and OPC UA
OPC Factory Server V3.6 Large
6
Description License type Reference Weight
kg/lb
OPC Factory Server Single station TLXCDLUOFS36 –
V3.6 Large software 10 stations TLXCDLTOFS36 –
bb Unlimited number of

7
items (1) 200 stations TLXCDLFOFS36 –
bb Protocols supported:
OPC DA, OPC XML-DA
and OPC UA
OPC Factory Server V3.6 upgrades
Description Reference Weight
kg/lb

8
Update for OPC Factory TLXCDUPDSOFS –
Server V3.6 Small

Update for OPC Factory TLXCDUPDLOFS –


Server V3.6 Large

(1) “item”: variable, structure, table etc. in the Unity Pro application.

10

Presentation: Architectures: Setup: Functions: Time-stamping system:


page 3/2 page 3/3 page 3/5 page 3/6 page 3/8

3/7
Presentation Software 3

OPC data server software


Time stamping system

Presentation
The time stamping system is a complete solution providing a SCADA with a
1 sequence of events that are time-stamped at source, enabling the user to analyze
the source of any abnormal behavior in an automated system.

The SOE (sequence of events) is displayed in the alarm log or in the list of events for
a client such as a SCADA.

2 Each event in the SOE is a change of value (transition) of a discrete I/O detected by
a time stamping module.

Advantages
Using the time stamping system has the following advantages:
bb No PAC programming
bb Direct communication between the time stamping modules and the client. If the
3 time stamping modules are in an Ethernet I/O drop, the bandwidth of the PAC
communication is not used
bb Consistency of the I/O values between the process (time stamping modules) and
the client
bb Consistency is maintained irrespective of the operating mode
bb No loss of events under normal operating conditions
bb Management of Hot Standby configurations on the PAC and/or SCADA
4 redundancy

Composition of a time stamping architecture


Vijeo Citect alarm
OFS server terminal or BMXCRA31210 and BMECRA31210 modules
Wonderware WSP
This time stamping module can be at the source of any discrete I/O signal located in
Quantum Ethernet the drop with a resolution of 10 ms.

5 M580
To avoid losing any events, all events are stored and kept in a buffer located in the
product until OFS takes them.
Synchronization of the CRA module uses the NTP protocol.

BMXERT1604T module
This module has 16 discrete inputs which carry out the time stamping on source
outputs with a resolution of 1 ms.

6 To avoid losing any events, the events are stored and kept in a buffer located in the
product until OFS takes them.
Routing function via This module can be placed either in an RIO drop, or in a local rack equipped with a
Ethernet Quantum NOC control
head 140NOC78100
BM●CRA31210 module.
or external router The CRA module is synchronized via the DCF 77 or IRIG-B standards.

OFS V3.6

7 OFS V3.6 is used to access events stored in the various buffers in the architecture
and to notify the SCADA of them via the standard OPC DA protocol.
BMX-CRA1 BMX-ERT1
event event
memory memory
Modicon X80
Time stamped variables can be provided by the BMXERT1604T, discrete modules
drops plugged into X80 drops, or even by the CPU since Unity V10.

8 BMX-CRA2
event
memory
BMX-ERT
event
memory
Vijeo Citect V7.3
Vijeo Citect V7.3 receives events transmitted by OFS and displays them in the SOE
Modicon X80
drops or in the list of alarms.

Wonderware WSP
BMX-CRA3 BMX-ERT
event event A specific OFS V3.6 version dedicated to the Wonderware platform is available on

9 the Wonderware Global Customer Support site.


memory memory
Modicon X80
drops The OFS-WSP driver has the same features as OPC V3.6 – Large apart from the
following:
Example of a time stamping architecture bb It is licensed from a Wonderware environment only. It cannot be run outside a
Wonderware environment
bb It contains the server, the simulator, a sample client, configuration tool,
configuration manager, and a user manual

10 bb It is OPC DA compatible only (No OPC UA – No OPC XML)

Presentation: Architectures: Setup: Functions: References:


page 3/2 page 3/3 page 3/5 page 3/6 page 3/7

3/8
Performance Software 3

OPC data server software


Time stamping system

Performance
Performance Event source Value

Between two identical source modules in


module
BMXERT1604T 1.6 < resolution < 3.3 ms
1
the same rack BM●CRA31210 10 ms
Between two different inputs in the same BMXERT1604T 1 ms
source module BM●CRA31210 1 scan
Maximum number of events scanned BMXERT1604T 400 events (1)

Maximum number of I/O and memory


BM●CRA31210
BMXERT1604T
2,048 events (1)
16 discrete inputs on module 2
available
512 events in internal buffer
BM●CRA31210 256 discrete I/O configured
4,000 events in internal
buffer

3
Maximum number of source modules in an BM●CRA31210 1 per drop
Ethernet remote drop BMXERTpppp 9 per drop
Maximum number of event sources BMXERTpppp 500 sources per second (1)
controlled
(1) This maximum value is not an absolute value. It depends on the overall system dynamics
(total number of scanned items and number of events generated by the system).

10

Presentation: Architectures: Setup: Functions: References :


page 3/2 page 3/3 page 3/5 page 3/6 page 3/7

3/9
Index Product reference index

# UNYSPULZSUV1X 1/22
110XCA28201 1/25 UNYSPULZTV1X 1/22

1 110XCA28202
110XCA28203
1/25
1/25
UNYSPULZUGV1X
UNYSPULZUV1X
1/22
1/22
990NAA26320 1/25 UNYSPUSFGV1X 1/21
990NAA26350 1/25 UNYSPUSFTV1X 1/21
UNYSPUSFUV1X 1/21
B UNYSPUSZGTV1X 1/21

2 BMXXCAUSBH018
BMXXCAUSBH045
1/25
1/25
UNYSPUSZGV1X
UNYSPUSZTV1X
1/21
1/21
UNYSPUSZUGV1X 1/21
S UNYSPUSZUV1X 1/21
SR2CBL06 1/25 UNYSPUXEFV1X 1/24
STBXCA4002 1/25 UNYSPUXFFV1X 1/24

3
UNYSPUXFGV1X 1/24
T UNYSPUXFTV1X 1/24
TCSWAAC13FB 1/25 UNYSPUXFUV1X 1/24
TLXCDLFOFS36 3/7 UNYSPUXZEFV1X 1/24
TLXCDLTOFS36 3/7 UNYSPUXZEGV1X 1/24
TLXCDLUOFS36 3/7 UNYSPUXZETV1X 1/24
TLXCDSTOFS36 3/7 UNYSPUXZEUV1X 1/24

4 TLXCDSUOFS36
TLXCDUPDLOFS
3/7
3/7
UNYSPUXZGTV1X
UNYSPUXZTFV1X
1/24
1/24
TLXCDUPDSOFS 3/7 UNYSPUXZUGV1X 1/24
TSXCRJMD25 1/25 UNYSPUZFUCD80 2/3
TSXCUSB485 1/25 UNYXCAUSB033 1/25
TSXPCX1031 1/25

5 U
UAGSBTCFUCD10 2/9
UAGSBTDFUWB13 2/9
UNYDFFXZZSPA80 2/5
UNYLAGZAUWB20 2/9

6
UNYLFZZAUWB12 2/9
UNYLHVZAUWB10 2/9
UNYLPCZAUWB 2/9
UNYLTSZAUWB10 2/9
UNYSPUEEFV1X 1/23
UNYSPUEFFV1X 1/23
UNYSPUEFGV1X 1/23
7 UNYSPUEFTV1X
UNYSPUEFUV1X
1/23
1/23
UNYSPUEZFV1X 1/23
UNYSPUEZGTV1X 1/23
UNYSPUEZGV1X 1/23
UNYSPUEZLGV1X 1/23

8 UNYSPUEZLTV1X
UNYSPUEZLUV1X
1/23
1/23
UNYSPUEZTV1X 1/23
UNYSPUEZUGV1X 1/23
UNYSPUEZUV1X 1/23
UNYSPULFFV1X 1/22

9
UNYSPULFGV1X 1/22
UNYSPULFTV1X 1/22
UNYSPULFUV1X 1/22
UNYSPULZFV1X 1/22
UNYSPULZGTV1X 1/22
UNYSPULZGV1X 1/22
UNYSPULZMGV1X 1/22
10 UNYSPULZMTV1X
UNYSPULZMUV1X
1/22
1/22
UNYSPULZSGV1X 1/22
UNYSPULZSTV1X 1/22

3/10
Schneider Electric Industries SAS www.schneider-electric.com
Head Office The information provided in this documentation contains general descriptions and/or technical
35, rue Joseph Monier characteristics of the performance of the products contained herein. This documentation is
F-92500 Rueil-Malmaison not intended as a substitute for and is not to be used for determining suitability or reliability of
France these products for specific user applications. It is the duty of any such user or integrator to
perform the appropriate and complete risk analysis, evaluation and testing of the products with
respect to the relevant specific application or use thereof. Neither Schneider Electric nor any
of its affiliates or subsidiaries shall be responsible or liable for misuse of the information
contained herein.

Design: Schneider Electric


MKTED2140504EN

Photos: Schneider Electric

January 2018 - V4.0

You might also like