Job Description
CM Analysis
Found abnormal vibration on fan both end bearings and synchronous energy in
horizontal direction.
High Dominant peak at first order 1X with a sinusoidal waveform is clearly an indication
of unbalance symptoms of fan. There may be coating/dust build up on fan impeller.
Fan both end bearings are normal in operation.
Detailed summary of spectrums and vibration summary is given below.
Recommendation
Following are Recommended based on above analysis :
Stop the fan and look for its cleaning or any wear tear.
Cleaning must be removed properly before attempting dynamic balancing.
Replace the Fan both end bearings Lube oil.
According to ISO 10816 Vibration severity standard fan is running in unsatisfactory
region.
Prepared By
Approved By
Reliability Engineer Manager Planning
Oct,2016 Page 1
Spectrums:
raw - Raw Mill Bag House Fan
421 FN 2 -F1H Fan Inboard Horizontal
6
Route Spectrum
5 03-Nov-16 15:36:55
OVERALL= 4.60 V-DG
RMSVelocity in mm/Sec
4 RMS = 4.57
LOAD = 100.0
3 RPM = 711. (11.85 Hz)
0
0 3 6 9 12 15 18 21
Frequency in Orders
10
Route Waveform
03-Nov-16 15:36:55
5 RMS = 4.36
PK(+/-) = 8.80/7.81
Velocity in mm/Sec
CRESTF= 2.02
0 FAULT
ALERT
ALERT
FAULT
-5
-10
Ordr: 1.000
0 50 100 150 200 250 300 350 400 Freq: 11.86
Time in mSecs Spec: 4.192
5 RMS = 5.50
LOAD = 100.0
4
RPM = 711. (11.85 Hz)
3
2
2.00
11.00
11.99
13.99
14.99
15.99
10.00
12.99
16.99
1
3.00
5.00
6.00
8.00
4.00
7.00
9.00
0
0 3 6 9 12 15 18
Frequency in Orders
12
Route Waveform
8 03-Nov-16 15:32:59
RMS = 5.66
4 PK(+/-) = 10.31/10.93
Velocity in mm/Sec
CRESTF= 1.93
0 FAULT
ALERT
ALERT
FAULT
-4
-8
-12
Ordr: 1.016
0 50 100 150 200 250 300 350 400 Freq: 12.03
Time in mSecs Spec: 5.035
Oct,2016 Page 2
Abbreviated Last Measurement Summary
************************************
-------------------------------------------------------------------------------
Clarification Of Vibration Units:
Acc --> G-s RMS
Vel --> mm/Sec RMS
Oct,2016 Page 3
Cement Mill 2 and 3 vibration readings
************************************
-------------------------------------------------------------------------------
Oct,2016 Page 4
Following are the readings of cement mills Renk Gearboxes vibration tripping limits
of CCR. If one of them reach to this specific vibration ( limit ) or exceed then Cement
Mill will be tripped.
Observations:
Observed almost similar vibration readings of both cement mills in CCR and
vibration Analyzer CSI- 2130 highlighted above.
Rizwan Ahmed
Condition Monitoring Engineer
Ajil Alsalmani
Planning Manager