You are on page 1of 11
Soles Head Quarter = SHAVO sHAvo Nonsten DAY PVF EB “ol: 0222087655980 / 9638210333 mall: shavo@shavoinci.com {An ISO 9001:2015 Company CERTIFICATE OF ORIGIN We, hereby certify that, the goods covered under Export Invoice No. SN/EXP/156/21-22 dated 23TH MARCH, 2022 (PNEUMATIC UNITS) @ SS FIL/REG SB37-400-A9MN-BHX - 2 Nos @ FIL/REG 11-4SN-201M-M6KN-NB. -1 No @ VOL.BOOSTER SVB60-AS3N-LBX - 2 Nos are of Indian Origin. ISSUED AT MUMBAI ON THIS 28TH DAY OF MARCH, 2022. For SHAVO NOR\ oe eo PVT.LTD. ee. AEGISTERED OFFICE 74, Mitat Chambers, Harman Poin, Murs - 400021 Soles Hood Quarter ° SHAVO SHAVO NORGREN (INDIA) PVT.LTD. ‘Tan@-Bolapur Road, Rabale, FIRST WANE IW PHEUMATICS ‘Nav Mure - 400701 ‘To: 022208795 909832210222 mall: shave@shavoinda.com ‘An 150 9001 Company Date: 29.03.2022 To whomsoever It May Concern SHAVO NORGREN (INDIA) PVT. LTD. MANUFACTURERS OF MODEL $B37-400- ASMN-BHX (Qty: 2 no’s) HEREBY CERTIFY THAT THE ABOVE REFERRED PRODUCTS. ARE MANUFACTURED IN COMPLIANCE OF TECHNICAL PARAMETER MENTION IN THE DATASHEET. PARTY NAME: M/s LIWA PETROLEUM & INDUSTRIAL SUPPLIES LLC PO NO: 1432/22 DT: 15.03.2022 WO NO: 21427 Invoice No: 6491 DT: 29.03.2022 (AUTHORISED SIGNATORY] REGISTERED OFFICE 74, Mal Chambers, Nariman Point, Mumbai - 400021 VEF weppcrion cennimcate Sr.No 450 9001:2015 (DINEN 10204 CL-3.1) Date 29/03/2022 (Pary’sName > Lia Petroleum & Industrial supplies CCC [Pariy's P.O. Ref. = 1432732 ‘Date:- 15/03/2022 | Product Deseripton: SS FILTER/REGULATOR WO No. :214277 —Date: 15-03-2022 Model ~~ 5B37-400-ASMN-BHX.. | [Qe : 02 NOS. - | CHEMICAL PROPERTIES | se CE] MYST CRY Wake | NRG PR No 0s 1s | nar is os | 00 004 1] wo | cram | nee. | wa wae vax max | max j | io ame) as | Toor | 8 | ams | TE aa ons | Ty 0 | 2B 3s at oe es | 2) poms | cram | REF | | wax va as | wan | naa ous. —T i 7 Te Tat 1s | O13 | bow | b0F 3 | cr Bowian | cess wax | wa wax [sine | | i | | aor Sa | oe | TO saa] woos | 008] ons | PHYSICAL PROPERTIES [SE ar: | weto—] —Texsice —PELGRTIONT | HARDNESS GBT No | srmenern | —staenora * Cinna. | tNinmeay | 308 asi max I - | Soni” | ss z 7 vf oa fer Poms | oe | sass fn ow | 3 | BowleaD | CF3M ae 243.99 | 164 | _1 = - _ _ J 1[Page REMARKS; A) The above certification is based on TC's available with us: { 1) AINo. 4042 DT: 17-08-2021, 3) AINo. 126 DT: 06.04-2021, 2) AINo. 4042 DT-17-08-2021, equirements ofthe order and all est results are acceptable. Shavo Norgren (India) Pv. Lid Mumba mall: shavo@shavoindiacom Website : ww shavoindia.com QUALITY CONTROL, | SHAVO NORGREN (INDIA) PVT. LTD. SHAVO e545, M.D.C., TTC INDUSTRIAL AREA RABALE, NAVI MUMBAI - 400 701, MAHARASHTRA, INDIA. FIRST NAME IN PHEUMATICS TEL. : +91-22-20879586 / 20879587 Email: shavo@shavoindia.com Website : www.shavoindia.com WARRANTY It is certified that SHAVO Products manufactured by our factory are under warranty, for a period of TWELVE Months from the date of purchase by the customer against defects in material and workmanship. Our obligation under this warranty is limited to the replacement of any defective part or parts which come within the scope of this warranty, provided the product is being returned to us carriage paid. This warranty is valid only when our product is used in accordance with the printed instructions issued by us. We undertake to replace defective parts free of charge in our factory any faults which not with standing normal and appropriate treatment can be proved to have their origin in inferior material or defective construction during the period of warranty. No allowance will be granted for any alteration made by the customer without our company's written consent and no claim for expenditure upon our products will be allowed and also no claim for consequential damages will be entertained. All defects due to damage during transit storage, misuse or mishandling by the customer are not covered under this warranty. For SHAVO NORGREN (INDIA) PVT. LTD re (Authorised Signatory) Party Name LIWA PETROLEUM & INDUSTRIAL SUPPLIES LLC Party's Order Ref 1421/22 1432722 Dated : 0703/2022 15/03/2022 Our W.0. No 214172,214277 Delivery Challan No. '$16862,S/6863, dt. 29103/2022,29/03/202 Invoice No. 6491 it, 29/03/2022 ‘QFIWC/001 RO wi 01.01.18, REGISTERED OFFICE : 174, MITTAL CHAMBERS, NARINAN POINT, -MUNBAI - 400021 INSTALLATION & MAINTENANCE SHAVO INSTRUCTIONS (MANUAL) Furmavenmemans MODEL SB37_ AR FILTER REGULATOR ‘STAINLESS STEEL SERIES TECHNICAL SPECIFICATION See FILTER REGULATOR : (tor 3 3/871 4) Basie general trouble shooting: WARNING: 2) Ordinary maintenance: 8 1 Ueseneamorpiee 1 Aaatoconrsion nd shocker fl | 5 Smylie 4 ‘SB27H - (HIGH FLOW VERSION) (PAGE 2 OF 2) STANOARO UNIT ATEX UNIT ‘i “a 0G Det ; Or oo COMMON PART LIST common Part usr ‘S837 (STANDARD VERSION) & S637H (HIGH FLOW VERSION) ‘S837 (STANDARD VERSION) & SB37H (HIGH FLOW VERSION) (PAGE 1 0F 2) (PAGE 2 OF 2) ¥) Other Replacement Part: 4. COMMON PARTS (For 11", 38%, CE es El ee Ow ts) AIR FILTER / REGULATOR - Stainless Steel SB37 (6 1/2, 3/4) Features © Shayo's Filter/Regulator combination model SB37_unit, for esse Elena pati ie Th instrument airuse in corrosive atmosphere. «Applications, include marine environments, oil and gas APP eate snd ieaiSand Roos précscsing, miedical analysts © CE, EAC [(CUTR-10) equivalent to GOST &k approved SIL3 capable as perlEC 61508. AllExternal parts are NACE MR 0175" approved. (National Assqc usd inolwelsan oes on eed i Pras ne Operating Teo. (Abin) FeeSemant a tera ot Constan ‘od Bonet owt Diptage Asentiy [Bowl Capaciy Roganed ncondar posure ‘Sands Nara Fw Ral a OBE [sSdptint recs Stare pet | pesrsnaops ears poems Dain Prosi Adeeat age Pn a Gua aa) Moira ‘ation of Corrosion Engineers MR-O175 defines or pulphige ‘stress crac ‘corrosive environments} ing resistant materials Pr. BSe spar 43508) trih lal bowl Maral dis -85 p20 be) itl ont ude 10p99 (108 ba) Biman ~ Sino S40 moo" -Opioral S826 = Sit” Seleed Bene -Opna ‘Stra: So! por ASISTOL 5 Hel wah NACE complance (0175) sa10. {5.3161 wah NACE complance Mt 0175) Sprites Ruther wehout PTFE = Sandel {Tore Nile LNSR) ANC 80°C) Pou asciez0 Fucceaten (vin SKM) 20°01 180°C no) avcie ae 0 S00" (150-160) = Sanda Ozteztbe (30-30pal) Opto Oat anow (60-s0pa1) - Open Beciedabarltes-12eps) = Oprona 1701 17Sba (25-2500) - Opera E277 seen 132 are) [47-355 en (160 tes) Ww 6a) sie (6659) Nenual-Stndand ——_Auomatis-ptorl Relea. Stanerd — Non-ilesrg = Optans ec Hadea Adjusting srw ~ Standard Thende = optora ‘Wt OSPF (Fo) Saran We NPT F)__> Open Som 00 Noma) - Stans Mil Mouning Bracket pte 1) Presaue gauge wnt nav CE, EAC, S83 and NAGE MR 0175 aporova 2) Put nsumng back gu sre nila rave NACE MR O178 Dra 5) Aliomste eran avin wn Nine pasomers Giz 277 scim (122 dose) aa" 355 scim (189 dese) -Vahios ingested are with 4 micron etaments, wt fer eames thse va Mumba, India 2588 2588 Manual Metal 125-125 psi Roteving Manual Metal 125-125 psi_—_ Relieving ibe ove. 'SB37-400-M7LANHE, ‘$897-600-M7LANHE, 2001 SHAVO TEST CERTIFICATE S1.No: $9659 780.9001" 2015 Date: 29.03.2022 Party's name: LIWA PETROLEUM & INDUSTRIAL SUPPLIES LLC. ParyePO.Re 4492222 ourw.o: 214277 Product descristion: F/L/REG a - ; Model: SB37-400-ASMN-BHX Size: 1/2"NPT Qy: 02NOS Invoice No.: 6491 DT. : 29.09.2022 PERFORMANCE TESTS OBSERVATIONS 41) LEAKAGE TEST: Unit pressurised with air of 17.5 kg/cm? and checked for leakage to atmosphere during flow and also total shut-off conditions, No leakage Satisfactory 2) PRESSURE ADJUSTMENT: Unit pressurised to manual operation of ‘Smooth over entire knob for smooth continuous regulation range Satisfactory of soc. pr. from 0 to 10 ka/em?. 3) ACCURACY (REGULATION) TEST: Unit subjected to two way variation (set Variation in set sec. pr. value of 10 kg/m? 10% of primary not exceeding # 3% of set value. pressure observing change in value of Satisfactory secondary pressure set at 7 kg/cm? with a flow of 8 am%sec. 4) RELIEF FUNCTION: Unit pressurised to build up of Satisfactory downstream pressure above set secondary pressure to test automatic relief to atmosphere. '5) PRESSURE DROP TEST: At a primary pressure of 10 kg/cm? and Pressure drop ess than secondary pressure value of 7 ka/om? at 15% of set value, 1no flow, flow increased to 8 dm/sec and Satisfactory drop in sec, pressure observed. 6) AUTOMATIC DRAIN OPERATION: Water injected in the compressed air line — ‘and operation of the eutomatic drain in Sea dumping out water collected in the bow! observed. "This is @ computer Generated TC hence acceptable " Signatory Not Required. Shavo Norgren (India) Pvt. Lt. Mumbai ‘e-mail: shavo@shavoindia.com ‘website : www.shavoindia.com

You might also like