You are on page 1of 3

WEST BENGAL MEDICAL SERVICES CORPORATION LTD.

(Wholly owned by the Government of West Bengal)


Swasthya Sathi, GN-29, Sector-V, Salt Lake, Kolkata-700 091

033-4034 0300, 033-4034 0400


Email ID – info@wbmsc.gov.in

CORRIGENDUM – I

TO

BIDDING DOCUMENTS

FOR

Supply, Fitting & Fixing of General Furniture at Jalpaiguri Medical College, Jalpaiguri, West Bengal

Bid Reference No.: WBMSCL/NIQ-134/2022 Dated: 09/04/2022


2

Sl. Page Section Clause/ Sl. Current Clause / Provision Changed Clause / Provision
No. No. No.
1 3 Terms & Sl. 10 The bid shall be valid for a period of 90 days from the Bids shall remain valid for a period not less than 180
Conditions for date of opening of Technical Bid. (one hundred twenty) days from the date of opening
Participating this of the Financial Proposal. However, extension of bid
validity may be suitably considered by the Tender
NIQ:
Inviting Authority, if required, subject to obtaining a
written confirmation of the contractor/bidder(s) to
that effect

2 3 Terms & Sl. 8 To be eligible for award of contract, Bidder / OEM To be eligible for award of contract, Bidder / OEM
Conditions for must possess following Certificates / Test Reports on must possess following Certificates / Test Reports on
Participating this the date of bid opening (to be uploaded with bid): the date of bid opening (to be uploaded with bid):
Valid certificates i.e.,BIFMA, SEFA-10 and GREEN Valid certificates i.e., BIFMA, GREEN GUARD
NIQ:
GUARD Compliance, EN13150, EN14727. Powder Compliance. Powder Coating thickness must be 40-60
Coating test reports from any ISO 9001 certified micron & test reports from any ISO 9001 certified
OEM/agency of powder coating compounds against OEM/agency of powder coating compounds against
categories including : dry film thickness test, Gloss categories including : dry film thickness test, Gloss
@60 degree test, hardness test, impact resistance @60 degree test, hardness test, impact resistance
test, Cross cut adhesion test, Elasticity-Cupping test, test, Cross cut adhesion test, Elasticity-Cupping test,
Salt spray test, Conical Bend Test as per ASTM D522 Salt spray test, Conical Bend Test as per ASTM D522
(Certifications of OEM/agency needs to be attached), (Certifications of OEM/agency needs to be attached),
ISO 45001:2018, ISO 14001 &ISO 50001:2018. ISO 45001:2018, ISO 14001 &ISO 50001:2018. Bidders
Bidders should have GRIHA/ SVAGRIHA/ BIFMA/ should have GRIHA/ SVAGRIHA/ BIFMA/ FICCI/
FICCI/ ASSOCHEM etc certification as applicable for ASSOCHEM etc certification as applicable for this type
this type of work. of work.

3 4 Terms & Sl.14 Delivery: The Furniture items should be delivered, Delivery: All the Furniture items should be delivered,
Conditions for placed, installed and commissioned at Medical placed, installed and commissioned at Medical College
Participating this College Campus, within stipulated time period from Campus, within stipulated time period from date of
date of issue of letter of award. Supply and issue of letter of award.
NIQ:
installation of laboratory furniture with necessary
placement of sink and tap units and necessary
3

Sl. Page Section Clause/ Sl. Current Clause / Provision Changed Clause / Provision
No. No. No.
electrical points and light sources with complete
internal wiring wherever required.

4 6 C.Tender Process Sl.3 Dully filled in copies of Section – II (Forms I to IV) , Dully filled in copies of Section – II (Forms I) Sec-III
FORM-V in Section- III & Annex-A:Mandate form for (Form II, III, IV & V) & Annex-A:Mandate form for e-
e-payment in prescribed proforma with proper dated payment in prescribed proforma with proper dated
signature in the relevant spaces to be uploaded signature in the relevant spaces to be uploaded
electronically. electronically.

Documents in support of the information furnished Documents in support of the information furnished in
in Forms Section-II (Form I to IV), must be Forms Section-II (Form I & Section-III (Form II to IV),
attached/uploaded for evaluation and the file must be attached/uploaded for evaluation and the file
number & page number has to be indicated in the number & page number has to be indicated in the
respective column of the Form. respective column of the Form

You might also like