Sl. Page Section Clause/ Sl. Current Clause / Provision Changed Clause / Provision
No. No. No.
1 3 A.Terms & Sl. 10 The bid shall be valid for a period of 90 days from the Bids shall remain valid for a period not less than 180
Conditions for date of opening of Technical Bid. (one hundred twenty) days from the date of opening
Participating this of the Financial Proposal. However, extension of bid
validity may be suitably considered by the Tender
NIQ:
Inviting Authority, if required, subject to obtaining a
written confirmation of the contractor/bidder(s) to
that effect

2 3 A.Terms & Sl. 8 To be eligible for award of contract, Bidder / OEM To be eligible for award of contract, Bidder / OEM
Conditions for must possess following Certificates / Test Reports on must possess following Certificates / Test Reports on
Participating this the date of bid opening (to be uploaded with bid): the date of bid opening (to be uploaded with bid):
Valid certificates i.e., BIFMA, SEFA-10 and GREEN Valid certificates i.e. BIFMA, SEFA-10 and GREEN
NIQ:
GUARD Compliance, EN13150, EN14727. Powder GUARD Compliance, EN13150, EN14727. Powder
Coating test reports from any ISO 9001 certified Coating thickness must be 40-60 micron & test reports
OEM/agency of powder coating compounds against from any ISO 9001 certified OEM/agency of powder
categories including : dry film thickness test, Gloss coating compounds against categories including: dry
@60 degree test, hardness test, impact resistance film thickness test, Gloss @60 degree test, hardness
test, Cross cut adhesion test, Elasticity-Cupping test, test, impact resistance test, Cross cut adhesion test,
Salt spray test, Conical Bend Test as per ASTM D522 Elasticity-Cupping test, Salt spray test, Conical Bend
(Certifications of OEM/agency needs to be attached), Test as per ASTM D522 (Certifications of OEM/agency
ISO 45001:2018, ISO 14001 &ISO 50001:2018. needs to be attached), ISO 45001:2018, ISO 14001
Bidders should have GRIHA/ SVAGRIHA/ BIFMA/ &ISO 50001:2018. Bidders should have GRIHA/
FICCI/ ASSOCHEM etc certification as applicable for SVAGRIHA/ BIFMA/ FICCI/ ASSOCHEM etc certification
this type of work. as applicable for this type of work.
3

Sl. Page Section Clause/ Sl. Current Clause / Provision Changed Clause / Provision
No. No. No.
3 4 A.Terms & Sl.14 Delivery: The Furniture items should be delivered, Delivery: All the Furniture items should be delivered,
Conditions for placed, installed and commissioned at Medical placed, installed and commissioned at Medical College
Participating this College Campus, within stipulated time period from Campus, within stipulated time period from date of
date of issue of letter of award. Supply and issue of letter of award.
NIQ:
installation of laboratory furniture with necessary
placement of sink and tap units and necessary Supply and installation of laboratory furniture with
electrical points and light sources with complete necessary placement of sink, Laboratory faucet, valve
internal wiring wherever required. etc. with complete pipeline for inlet and outlet and
electrical Switch, Socket, light fittings etc with
complete internal electrical wiring as per standard
wherever required will be within the scope of the
Bidder. Source of Water inlet and waste outlet and
Electricity Source will be provided within the room.

4 20 Section-III, BOQ UNIT – No. UNIT – Feet


FORM-V Item No.4

5 2 D.Details Sl.4 Item Description: Island Laboratory Workbench: Item Description: Island Laboratory Workbench:
Specification of
Furniture Supply and placing of laboratory tables as per the Supply and placing of laboratory tables as per the
approved layout. All C-Frames assemblies should be required furniture layout.
manufactured from standard hollow metal sections;
confirming to I.S. Code 7138:1973 (Indian Standard C-FRAME SYSTEM: All C-Frames assemblies should
specification for steel tubes for furniture) and all be manufactured from standard hollow metal
sheet metal components should be of CRCA sections; confirming to I.S. Code 7138:1973 (Indian
confirming to IS Code 513:1994. The suspended Standard specification for steel tubes for furniture)
under-bench welded units should be supported on and all sheet metal components should be of CRCA
heavy-duty steel frames fully carrying the load of confirming to IS Code 513:1994. The suspended
worktops. Its superior strength combined with under-bench welded units should be supported on
aesthetically appealing end caps shall give maximum
4

Sl. Page Section Clause/ Sl. Current Clause / Provision Changed Clause / Provision
No. No. No.
flexibility and modularity while making a layout. C- heavy-duty steel frames fully carrying the load of
frame should be constructed from a rectangular pipe worktops. Its superior strength combined with
with a cross section of 60mm x 30mm and should be aesthetically appealing end caps shall give maximum
2 mm thick and should be without a vertical front leg flexibility and modularity while making a layout. C-
to give a clean look. This shall provide more knee frame should be constructed from a rectangular pipe
space or leg space and would facilitate uninterrupted with a cross section of 60mm x 30mm and should be 2
lateral movement of the under-bench units within mm thick and should be without a vertical front leg to
the bench run. The C-frame legs should be supplied give a clean look. This shall provide more knee space
with adjustable feet (tolerance from -5mm to or leg space and would facilitate uninterrupted lateral
+20mm) to correct the unevenness of flooring. The movement of the under-bench units within the bench
tubular enclosed type of construction shall run. The C-frame legs should be supplied with
discourage dust accumulation and unwanted adjustable feet (tolerance from -5mm to +20mm) to
development of bacteria & fungus. Drainage gradient correct the unevenness of flooring. The tubular
should be well adjusted throughout the length of enclosed type of construction shall discourage dust
table and should have horizontal supports for accumulation and unwanted development of bacteria
drainage systems. The structure should have a & fungus. Drainage gradient should be well adjusted
removable back panel to provide access for throughout the length of table and should have
maintenance throughout the length of table. The C- horizontal supports for drainage systems. The
frame shall also have skirting at back bottom side. It structure should have a removable back panel to
should be suitable for sitting and standing nominal provide access for maintenance throughout the length
heights of 750mm & 900mm respectively depending of table. The C-frame shall also have skirting at back
on the layout and the requirement of the laboratory. bottom side. It should be suitable for standing
The table depth should be 1540 mm. The length of nominal heights of 900mm respectively for the
the table should be as per the approved layout (or laboratory. The table depth/width should be 1540
BOQ). The horizontal members which should connect mm. The length of the table should be as per the
the c-frames should be made from rectangular pipes approved laboratory furniture layout.
of 2mm thickness. Cross-sectional dimensions of the
pipe should be 60 x 30 x 2 mm. They should be made HORIZONTAL MEMBERS: The horizontal members
of CRCA MS and coated with pure epoxy powder. which should connect the c-frames should be made
They should be available in various widths of 600, from rectangular pipes of 2mm thickness. Cross-
750, 900, 1050, 1200, 1350, 1500, 1650, and 1800, sectional dimensions of the pipe should be 60 x 30 x 2
depending on the layout of the laboratory furniture. mm. They should be made of CRCA MS and coated
5

Sl. Page Section Clause/ Sl. Current Clause / Provision Changed Clause / Provision
No. No. No.
The cover panels should cover the service lines that with pure epoxy powder coating of thickness 40-60
runs behind for the wall side units and through the micron. They should be in combination of various
middle for the island units. These should be easily lengths (modular type) of 600/ 750/ 900/ 1050/
removable (unclipped) and the service line be 1200/ 1350/ 1500/ 1650/ 1800, depending on the
accessed for maintenance. They should be made of layout of the laboratory furniture.
CRCA MS with pure epoxy powder coating and are of
1mm thickness. The master upright should be of the REMOVABLE BACK PANELS: The cover panels
dimensions: 300 x 150 x 1.2 mm. It should be made should cover the service lines (eg: for sink,
from 1.2mm thick CRCA MS with pure epoxy powder Laboratory faucet, Valve etc. with complete pipeline
coating. It should have an open-able door for easy for inlet and outlet and electrical Switch, Socket,
service maintenance and should extend till the false light etc with complete internal electrical wiring as
ceiling. The vertical upright should form the per standard wherever required) that run through
backbone for internal distribution of GDS, electrical the middle for the island units. These should be easily
supply systems shelves and top units and should be removable (unclipped) and the service line should be
constructed from 16-gauge CRCA formed steel panels accessed for maintenance. They should be made of
with removable covers. Shelf height should be CRCA MS of 1mm thickness with pure epoxy powder
adjustable with an increment of 1inch / 25mm. coating.
Uprights should be supplied with adjustable feet
from -5mm to +20mm. Depending upon the layout, COVER PANELS: All side cover panels and back
height adjustable shelves should be provided panels, filler panels should be made from CRCA MS
between uprights with 1” of height adjustability. The panels of 1.0 mm thickness with pure epoxy powder
ends and intermediate vertical supports should be coating
2mm thick aluminum extrusion with MS brackets of 2
mm thick. Toughened glass should be put-on over MASTER UPRIGHT: The master upright should be of
these shelves for taking care of bottle the dimensions: 300 x 150 x 1.2 mm. It should be
marks/corrosion. Suspended welded cabinet body made from 1.2mm thick CRCA MS with pure epoxy
should be of flush face construction with intersection powder coating. It should have an open-able door for
of vertical and horizontal members like LH and RH easy service maintenance and should extend till the
side panel along with front horizontal channel, back false ceiling.
panel and bottom panel.The storage cabinets should
have the provision for horizontal sliding to make VERTICAL UPRIGHT: The vertical upright should
available leg space as per the need. It should have form the backbone for internal distribution of GDS,
6

Sl. Page Section Clause/ Sl. Current Clause / Provision Changed Clause / Provision
No. No. No.
the provision for relocation anywhere easily as it electrical supply systems shelves and top units and
should be an independent unit. Cabinet should be of should be constructed from 16-gauge CRCA formed
square non-sharp edge construction. Doors should steel panels with removable covers. Shelf height
be assembled with SS-304 hinge assembly. should be adjustable with an increment of 1inch /
Removable back panel should be provided to easily 25mm. Uprights should be supplied with adjustable
access the service lines running behind the cabinet feet from -5mm to +20mm.
benches. Intermediate horizontal channels should be
provided between door and drawer. Shelf should be ADJUSTABLE REAGENT SHELVES: Depending upon
eight bend panel with 20mm height. Drawer tray the layout, height adjustable shelves should be
should be of single piece construction. Drawer should provided between uprights with 1” of height
be well supported on LH and RH ball slide suspension adjustability. The ends and intermediate vertical
system. Steel door and drawer front should be of supports should be 2mm thick aluminum extrusion
double wall construction with sound dampening with MS brackets of 2 mm thick. Toughened glass
material filled inside. Doors should be easily should be put-on over these shelves for taking care of
removable, and hinges should be easily replaceable. bottle marks/corrosion.
Knee space panel should be in 22-gauge
construction. The dimensions of the cabinets should WELDED UNDER-BENCH STORAGE CABINETS:
be W = 450/600 (as per the layout) D = 530mm, H = Suspended welded cabinet body should be of flush
635/485 mm. The configurations should be 1 face construction with intersection of vertical and
Shutter/ 2 Shutters and 1 Drawer as per the layout. horizontal members like LH and RH side panel along
The entire material construction for the storage units with front horizontal channel, back panel and bottom
should be MSCRCA: IS – 513 (1994). Thickness of panel. The storage cabinets should have the provision
LH/RH side panels, shutter front, Bottom panel, Top for horizontal sliding to make available leg space as
front, Drawer separator, shelf, Alignment channel per the need. It should have the provision for
should be of 1.2mm thk. Removable Back panel, relocation anywhere easily as it should be an
Shutter cover, Fr. Rack strip, Top cover panel should independent unit. Cabinet should be of square non-
be of 0.8mmthk. The finish of the welded cabinets sharp edge construction. Doors should be assembled
should be powder coated pure epoxy of thickness 40- with SS-304 hinge assembly. Removable back panel
50 microns. Handles should be AnodizedAluminium should be provided to easily access the service lines
Recessed-Type, of CTC:160.0mm. Units should have a running behind the cabinet benches. Intermediate
locking facility with 180° and 10 lever cam lock horizontal channels should be provided between door
mechanism. The hinges should be Knuckle-butt type and drawer. Shelf should be eight bend panel with
7

Sl. Page Section Clause/ Sl. Current Clause / Provision Changed Clause / Provision
No. No. No.
SS Hinge. The screws should be SS304. Shutter 20mm height. Drawer tray should be of single piece
should be of twin-type construction with sound construction. Drawer should be well supported on LH
dampening effect using profeel. Shutter cover should and RH ball slide suspension system. Steel door and
be equipped with Bump on for sound dampening. drawer front should be of double wall construction
Ball Slide for drawer units should be 500mm length. with sound dampening material filled inside. Doors
The service fittings should be laboratory grade, and should be easily removable, and hinges should be
water faucets and valve bodies should be cast red easily replaceable. Knee space panel should be in 22-
brass alloy or bronze forgings, all fittings should be gauge construction. The under storage units should be
powder plated unless specified otherwise. Fittings ergonomically distributed at an alternative intervals
should be identified with service indexes in the color with leg space of same length as that of the under
coding as per DIN 12920. The electrical trunking used storage unit.
for housing electrical switches and sockets, data and Dimensions: The dimensions of the cabinets should
voice points, its top panel, bottom panel of the be W = 300/450/600/750/900, D = 530mm, H =
trunking should be made from 1.0 mm thick CRCA 635/485 mm. Configuration: The configurations
MS panel. It should be available in both, single sided should be 1 Shutter/ 2 Shutters and 1 Drawer. MOC:
and double-sided configurations. It should be made The entire material construction for the storage units
from CRCA MS with pure epoxy powder coating. The should be MSCRCA: IS – 513 (1994). Thickness: LH/RH
front surface that houses the electrical points should side panels, shutter front, Bottom panel, Top front,
have a slope. The sinks should polypropylene molded Drawer separator, shelf, Alignment channel should be
construction made up of 5 mm thick high density and of 1.2mm thk. Removable Back panel, Shutter cover,
elastic poly propylene with good resistance to Fr. Rack strip, Top cover panel should be of 0.8mm
organic solvents. Bowl size should be 500 L x 400 W x thk. FINISH: The finish of the welded cabinets should
300 D mm. Faucet should be 3-way type. The be powder coated pure epoxy of thickness 40-60
worktop should be 19mm (+/- 2mm) thick Jet-Black microns. Handles should be Anodized Aluminium
Granite worktop. The exposed edges of the worktop Recessed-Type, CTC: 160.0 mm. LOCK: Units should
should be chamfered and smoothened. The bottom have a locking facility with 180° and 10 lever cam lock
of the worktop should be polished and there should mechanism. HINGES: Knuckle-butt type SS Hinge.
be a V-groove throughout the length of the exposed SCREW: SS304. Shutter should be of twin-type
edges to protect the cabinets from meeting the construction with sound dampening effect using
spillages. The overhang on the storage cabinet is 25 profeel. Shutter cover should be equipped with Bump
mm at the front side and 30 mm at the sides. The on for sound dampening. Ball Slide : for drawer units
backing material used is a neoprene mat of 6 mm should be 500mm length.
8

Sl. Page Section Clause/ Sl. Current Clause / Provision Changed Clause / Provision
No. No. No.
thickness. The laboratory furniture shouldmeet the
performance requirements described in the latest SERVICE FITTINGS AND ACCESSORIES: The service
SEFA 10-2016 class 7/8 guideline for the most fittings (Sink, Faucet, Valve, Light fittings, Tube Light,
adaptive range of furniture. The product should also Socket, Switch, drain board etc.) should be laboratory
have SEFA 8M-2016 for laboratory grade metal grade, and water faucets and valve bodies should be
casework. Should have the certification from the cast red brass alloy or bronze forgings, all fittings
competent SEFA approved test lab. It should also be should be powder plated unless specified otherwise.
mentioned on the website of SEFA Fittings should be identified with service indexes in
(https://www.sefalabs.com/). The product should be the color coding as per DIN 12920.
certified as per EN 13150; EN 14727.
ELECTRICAL TRUNKING: The electrical trunking used
for housing electrical switches and sockets, its top
panel, bottom panel of the trunking should be made
from 1.0 mm thick CRCA MS panel. It should be
available in both, single sided and double-sided
configurations. It should be made from CRCA MS with
pure epoxy powder coating. The front surface that
houses the electrical points should have a slope.

LABORATORY SINK AND ACCESSORIES: The sinks


should polypropylene molded construction made up
of 5 mm thick high density and elastic poly propylene
with good resistance to organic solvents. Bowl size
should be 500 L x 400 W x 300 D mm. Faucet should
be 3-way type. The worktop should be 19mm (+/-
2mm) thick Jet-Black Granite worktop. The exposed
edges of the worktop should be chamfered and
smoothened. The bottom of the worktop should be
polished and there should be a V-groove throughout
the length of the exposed edges to protect the
cabinets from meeting the spillages. The overhang on
the storage cabinet is 25 mm at the front side and 30
9

Sl. Page Section Clause/ Sl. Current Clause / Provision Changed Clause / Provision
No. No. No.
mm at the sides. The backing material used is a
neoprene mat of 6 mm thickness. One Sink should be
placed at every interval of 2.00-2.40 Metre of the
workbench.
[NOTE : Supply and installation of laboratory furniture
with necessary placement of sink, Laboratory faucet,
valve etc. with complete pipeline for inlet and outlet
and electrical Switch, Socket, light fittings etc with
complete internal electrical wiring as per standard
wherever required will be within the scope of the
Bidder/Agency. Source of Water inlet and waste
outlet and Electricity Source will be provided within
the room.]