You are on page 1of 4

LafargeHolcim

ACCOGROUT - MC 547
Microconcrete - Non Shrink

Integrated, Rapid, Robust

Use No Hooks
x
D M Y MRP Rs. (Inc. of all Taxex)

ACCOGROUT- MC547
Net Weight : 25 kgs.

Mfg & Mktd By : ACC Limited


121,
Regd. Off : ACC Limited, Cement House,
Mumbai-400020.
Maharshi Karve Road, Churchgate,
Contact : +91 22 - 33027545,
Customer Cell : + 91 9619660001
Email ID : enquiry.rmx@acclimited.com
Website : www.acclimited.com

Innovative Concrete Solutions Proudly Delivered By


People You Can Trust
Description: Note : The above test results were achieved under
ACCOGROUT - MC 547 is a ready to use nonshrink
Laboratory conditions. Tested at fluid consistency
general purpose Cemen ous Microconcrete
of 3.4 Ltrs of water of <10mm aggregates in ratio
specially designed for use where high strength and
2:1(by weight)
high fluidity is required for both new laying &
repairs. It is formulated as a natural aggregate
system with a shrinkage- compensa ng binder and Applica ons:
is highly flowable without sacrificing strength or Repairs of Slabs, Beams, Columns,
performance capabili es. ACCGROUT - MC547 is Founda ons etc.
formulated to provide consistency and exac ng As a grout material for larger gaps in structures.
performance in general purpose structural repairs.
This also can be used as a grout in various types of
applica ons in the project if larger width/space/
gaps available.

Characteristics:
Compressive Strength 70 mm cube, Mpa
1 day = > 20
3 days = > 30
7 days = > 45
28 days = > 60

Flexural Strength:
7 days = > 4Mpa
Advantages:
28 days = > 7Mpa
Highly fluid and extremely place able for easy
Split Tensile Strength: field use.
7 days = > 2Mpa High strength for maximum load bearing.
28 days = > 3Mpa
Non-Shrink with minimum posi ve expansion for
W/P Ratio = 0.12 high tolerance performance.
Non-bleeding and non-segrega ng at a fluid
Setting Time Hrs.
consistency.
Initial = 4
Final = 6 Does not contain any chlorides or addi ves which
may contribute to corrosion of base structure.
Water content per 25 kg bag in Ltr Flowable Total shrinkage compensa on, which provides a
consistency = 3.1 Ltr maximum bearing surface for the greatest overall
support.
Pourable consistency = 2.90 Ltr
Rapid strength gain to minimize turn around me
for equipment regrouts.
Flow Table Flow Rate in Cms = 21-25
Excellent working me at high ambient
Yield for 25 kg bag. M3 = 0.0125 temperatures.
Applica on Methodology : Health & Safety :
Ensure that concrete surface is clean, sound, Use mask, nose cover and hand gloves during
rough and is free from any standing water, oil, application.
dirt, debris, paint, unsound concrete or other clean hands with soap water after application.
contaminants. Avoid contact with skin/eyes. In case of unlikely
Ensure that surface temperature & ambient contact with eyes, rinse immediately with plenty
temperature is not <5 oC and >40 oC. of clean water, then cleanse with soap and
As a precau onary measure, remove all residues lukewarm water and seek medial advice. Do not
with a vacuum cleaner or pressure washing. use solvent to clean the contacted area.
Pre-soak the old concrete with water to ensure a Prevent swallowing. In case of unlikely swallowing,
saturated surface during the microconcre ng seek medical afternoon immediately. Do not
process. Mix 25 kg ACCOGROUT - Mc547. It can induce vomiting.
be mixed by paddle blender machine in bucket
or in drum type mixer at site. Do not mix more Packing :
microconcrete that cannot be used within 15 Available in 25 kgs bag
minutes as the mixture is workble only for 15
minutes of addi on of water. Storage :
Store in cool dry place under the shed away
Use requisite quan ty of water to achive desired
from heat.
flow level of ACCOGROUT Mc547. Do not add
excess water as this may lead to bleeding &
Shelf Life :
segrega on. Do not add sand / cement to 6 months if it is in original unopened sealed
ACCOGROUT - Mc547 as this may change its conditions
proper es.
Pour the mixture immediately a er mixing from
one side into a water ght shu ering. Ensure that
the air dispensed by pouring microconcrete
escapes and air entrapment is avoided. The
Microconcrete applica on should be con nuous
and maintain sufficient pressure head to keep it
flowing. To prevent mixture from leaking out, use
wooden or MS shu ering material with a
polythene sheets or coa ng covered sufficiency.
Ensure Proper curing of ACCOGROUT Mc547 to
achieve optimal durability / Performance of
microconcrete. Wet cure the Microconcrete untill
froms are stripped. Then cure the Microconcrete
with high solid curing compounds such as
ACCOCURE Wp601.

Cleaning & Maintenance :


Tools and mixer may be cleaned with Xylene or
Toluene solvents.