Description Advantages
ACCOGROUT UHS is a non-shrink high flow • Highly fluid and extremely placeable for
grout specially designed for use where high easy field use.
strength and high fluidity is required. It is • High strength for maximum load bearing.
formulated as a natural aggregate system with a • Non-Shrink with minimum positive
shrinkage- compensating binder and is highly flow- expansion for high tolerance performance.
able without sacrificing strength or performance • Non-bleeding and non-segregating at a
capabilities. ACCOGROUT UHS is formulated to fluid consistency.
provide consistency and exacting performance in • Does not contain any chlorides or
critical grouting operations. This also can be used additives which may contribute to
as a repair product in various types of application corrosion of base structure.
in the project. • Total shrinkage compensation, which
provides a maximum bearing surface
Characteristics for the greatest overall support.
• Rapid strength gain to minimize turn
Compressive Setting around time for equipment regrouts.
Strength 7 0 mm Time Hrs. • Excellent working time at high ambient
2
cube, Kg / Cm • Initial 4 temperatures.
• 1 day > 480 • Final 6
• 3 days > 550 Application Methodology
• 7 days > 650 Water
• 28 days > 800 content per • Ensure that concrete surface is clean,
W/P Ratio = 0.15 25 Kg bag, sound, rough and is free from any
Ltr standing water, oil, dirt, debris, paint,
• unsound concrete or other contaminants.
Flowable • Ensure that surface temperature & ambient
o o
consistency 4.125 temperature is not < 5 C and > 40 C.
• • As a precautionary measure, remove all
Pourable residues with a vacuum cleaner or pressure
consistency 4.000 washing.
• Pre-soak the concrete with water to ensure
Flow Table Flow Rate, 21 - 25 Yield for 25 0.0125 a saturated surface during the grouting
3
Cms Kg bag, M process.
Mix 25 Kg ACCOGROUT UHS with 4.125
Ltrs water for flow-able consistency.
Note : The above test results were Where grouting is to be done for deeper
achieved under Laboratory thickness (Bolt pocket grouting), add
conditions. Tested at fluid
about 9-10 Kg of pea gravel per 25 Kg of
consistency of 3.50 Ltrs of water per
ACCOGROUT UHS.
25 Kg Grout.
• Use requisite quantity of water to
achieve desired flow level of
Application
ACCOGROUT UHS. Do not add excess
• Heavy duty grouting of machinery and water as this may lead to bleeding &
equipment. segregation. Do not add sand / cement to
• Ball Mills in cement plants ACCOGROUT UHS as this may change
• Petro chemical & fertilizer units its properties.
• Bridge plates • Pour grout immediately after mixing from
• Bearing plates & Textile machineries the one side into a watertight shuttering
• Anchorages around the machine basement /
• DG sets structure. Ensure that the air dispensed
. for big crack filing. by pouring grout escapes and air
entrapment is avoided. The grouting
should be continuous and maintain
ACCOGROUT
Innovative Concrete Solutions Proudly Delivered By People You Can Trust
sufficient pressure head to keep grout Storage
flowing. To prevent grouts from leaking
out, use wooden or MS shuttering Store in cool dry place under the shed away
material with a polythene sheets or from heat.
coating of ShaliSlip.
• When grouting base-plate, pour grout Shelf Life
into the head box and allow to flow under 6 months in original unopened sealed
the plate. conditions.
Straps pre-placed under the plate will aid
in working the grout across. Grout should
be placed at minimum of 25 mm thick and
a maximum of 150 mm per lift when
placed in a large mass.
• Bring all ACCOGROUT UHS materials
as well as foundation and base-plate as
close to room temperature as possible.
Cold temperatures will significantly reduce
flow characteristics and will enhance
difficulty of base-plate grouting. Higher
temperatures will increase initial flow but
cut down on working time.
• Ensure proper curing of ACCOGROUT
UHS to achieve optimal durability /
performance
of grout. Wet cure the grout until forms
are stripped. Then cure the grout with high
solid curing compounds such as
SuperRezseal

Cleaning & Maintenance


Tools and mixer may be cleaned with Xylene
or Toluene solvents

Health & Safety


• Use mask, nose cover and hand gloves
during application.
• Clean hands with soap water after
application.
• Avoid contact with skin / eyes. In case of
unlikely contact with eyes, rinse
immediately with plenty of clean water,
then cleanse with soap and lukewarm
water and seek medical advice. Do not
use solvent to clean the contacted area.
• Prevent swallowing. In case of unlikely
swallowing, seek medical attention
immediately. Do not induce vomiting.

Packing
Available in 25 Kgs bag

You might also like