Innovative Concrete Solutions Proudly Delivered By People You Can Trust
Description Advantages ACCOGROUT UHS is a non-shrink high flow • Highly fluid and extremely placeable for grout specially designed for use where high easy field use. strength and high fluidity is required. It is • High strength for maximum load bearing. formulated as a natural aggregate system with a • Non-Shrink with minimum positive shrinkage- compensating binder and is highly flow- expansion for high tolerance performance. able without sacrificing strength or performance • Non-bleeding and non-segregating at a capabilities. ACCOGROUT UHS is formulated to fluid consistency. provide consistency and exacting performance in • Does not contain any chlorides or critical grouting operations. This also can be used additives which may contribute to as a repair product in various types of application corrosion of base structure. in the project. • Total shrinkage compensation, which provides a maximum bearing surface Characteristics for the greatest overall support. • Rapid strength gain to minimize turn Compressive Setting around time for equipment regrouts. Strength 7 0 mm Time Hrs. • Excellent working time at high ambient 2 cube, Kg / Cm • Initial 4 temperatures. • 1 day > 480 • Final 6 • 3 days > 550 Application Methodology • 7 days > 650 Water • 28 days > 800 content per • Ensure that concrete surface is clean, W/P Ratio = 0.15 25 Kg bag, sound, rough and is free from any Ltr standing water, oil, dirt, debris, paint, • unsound concrete or other contaminants. Flowable • Ensure that surface temperature & ambient o o consistency 4.125 temperature is not < 5 C and > 40 C. • • As a precautionary measure, remove all Pourable residues with a vacuum cleaner or pressure consistency 4.000 washing. • Pre-soak the concrete with water to ensure Flow Table Flow Rate, 21 - 25 Yield for 25 0.0125 a saturated surface during the grouting 3 Cms Kg bag, M process. Mix 25 Kg ACCOGROUT UHS with 4.125 Ltrs water for flow-able consistency. Note : The above test results were Where grouting is to be done for deeper achieved under Laboratory thickness (Bolt pocket grouting), add conditions. Tested at fluid about 9-10 Kg of pea gravel per 25 Kg of consistency of 3.50 Ltrs of water per ACCOGROUT UHS. 25 Kg Grout. • Use requisite quantity of water to achieve desired flow level of Application ACCOGROUT UHS. Do not add excess • Heavy duty grouting of machinery and water as this may lead to bleeding & equipment. segregation. Do not add sand / cement to • Ball Mills in cement plants ACCOGROUT UHS as this may change • Petro chemical & fertilizer units its properties. • Bridge plates • Pour grout immediately after mixing from • Bearing plates & Textile machineries the one side into a watertight shuttering • Anchorages around the machine basement / • DG sets structure. Ensure that the air dispensed . for big crack filing. by pouring grout escapes and air entrapment is avoided. The grouting should be continuous and maintain ACCOGROUT Innovative Concrete Solutions Proudly Delivered By People You Can Trust sufficient pressure head to keep grout Storage flowing. To prevent grouts from leaking out, use wooden or MS shuttering Store in cool dry place under the shed away material with a polythene sheets or from heat. coating of ShaliSlip. • When grouting base-plate, pour grout Shelf Life into the head box and allow to flow under 6 months in original unopened sealed the plate. conditions. Straps pre-placed under the plate will aid in working the grout across. Grout should be placed at minimum of 25 mm thick and a maximum of 150 mm per lift when placed in a large mass. • Bring all ACCOGROUT UHS materials as well as foundation and base-plate as close to room temperature as possible. Cold temperatures will significantly reduce flow characteristics and will enhance difficulty of base-plate grouting. Higher temperatures will increase initial flow but cut down on working time. • Ensure proper curing of ACCOGROUT UHS to achieve optimal durability / performance of grout. Wet cure the grout until forms are stripped. Then cure the grout with high solid curing compounds such as SuperRezseal
Cleaning & Maintenance
Tools and mixer may be cleaned with Xylene or Toluene solvents
Health & Safety
• Use mask, nose cover and hand gloves during application. • Clean hands with soap water after application. • Avoid contact with skin / eyes. In case of unlikely contact with eyes, rinse immediately with plenty of clean water, then cleanse with soap and lukewarm water and seek medical advice. Do not use solvent to clean the contacted area. • Prevent swallowing. In case of unlikely swallowing, seek medical attention immediately. Do not induce vomiting.