You are on page 1of 25

62' - 0"

13' - 1 1/4" 3 1/2" 3 1/2" 3 1/2" 36' - 11 1/4"


www.autodesk.com/revit
6' - 3 5/8" 6' - 29 5/8" 4' - 5 1/2" 4' - 8 1/2" 3' - 4 1/4" 3' - 6" 3' - 6" 15' - 2 3/4" 3' - 6" 3' - 6" 4' - 4 1/4"
A301
1
Consultant
Address
Address
1 1 1

3 1/2"
S&P S&P 2 2 2 2 Phone

8"
Fax
e-mail
W.I.C. W.I.C.

8' - 4 1/4"

8' - 4 1/4"
Consultant

10' - 2 1/2"
Address

10' - 6"
Address
12' - 3 3/4"

Phone
Fax
BEDROOM 3 e-mail

1' - 10 1/4"

16' - 3"
9'-0" CLG
10 23

1' - 10 1/4"
Consultant
GREAT ROOM

3 1/2"

22' - 0 9/16"
Address

19' - 10"
1' - 9 3/4"
9'-0" CLG Address

3 1/2"
Phone
Fax
Electrical e-mail
Panel
16
5 1/2"

(200 Amp)

5' - 5 1/2"
Media Panel 11' - 11 19/32" Consultant
2' - 6"

3 MIRROR 26 Address

FURN
Address

3 1/2"
1' - 7 1/4"
5' - 1"

Phone

3' - 5 3/4"
Fax
BATH 11

3 1/2"
e-mail
2' - 7"
35' - 6"

2' - 1"
9'-0" CLG
9' - 5 1/2"

3' - 2 1/2"
3 1/2"

3 1/2"

3 1/2"
3 9/16"
24 Consultant
3

8"
S&P Address
2' - 0 1/2"
CLOSET

A301 Address
15 3 1/2"
4' - 1"

4' - 1"
W.I.C. Phone
2' - 0 1/2"

21 Fax
S&P

S&P
e-mail

3 1/2"
3 1/2"

12 6
9 20' - 5"
W.I.C. 3' - 4 13/16" 10' - 11 1/2"

8' - 5 15/16"
13 1' - 8 3/16"
3 1/2"

9' - 5 7/16"
2' - 10 3/4" 2' - 9 1/4" 2' - 1" 1' - 8 1/4" 1' - 8 1/4" 3' - 2 1/2" 3' - 2 1/2"
1' - 8 1/4" STORAGE ROOM
1' - 8 1/4"
5' - 8" 3' - 4 1/2" 3' - 4 1/2" 6' - 5"
11' - 2 1/2"

9'-0" CLG 21' - 4 1/2"


3 1/2" 3 1/2"
3 1/2"

BEDROOM 4
15' - 8"
9'-0" CLG No. Description Date
5' - 0 1/2"

1 BEDROOM 5
9'-0" CLG 6' - 0"

1
16' - 7 1/2"

1 2
5' - 4"
A301 5' - 8 1/2"
A301 5' - 0 1/2" 1 5' - 0 1/2"

10' - 1"

3 1/2" 3 1/2"
12' - 0" 8" 12' - 0" 8"

Owner
EGDT1100
Basement Plan
Project number Project Number
Date Issue Date
Drawn by Author
Checked by Checker

4/27/2022 20:55:39
1
3 Basement
1/4" = 1'-0"
A0
Scale 1/4" = 1'-0"
1 2 3 4 5

A201

62' - 0"

A 7" 13' - 5 3/4" 3 1/2" 3 1/2" 5' - 1" 3 1/2" 37' - 3 3/4" 7"

6' - 8 1/8" 6' - 9 5/8" 4' - 1" 2' - 6 1/2" 2' - 6 1/2" 3' - 4 1/4" 3' - 6" 3' - 6" 7' - 0" 11' - 8 3/4" 8' - 2 3/4"

2
A301
3 3
7"

1 1

2' - 11 1/4"
2 2
DW

4' - 2 3/4"

7"
5

RANGE W/ HOOD
MASTER BATH

1'
VENT TO OUTSIDE

-
3

10' - 6 1/2"
MASTER

OVEN
15
2' - 4 1/4"
9'-0" CLG

/3
BEDROOM

2"
12' - 8 1/4"

MIRROR

1'
KITCHEN

-
9'-0" CLG

10
3

15' - 1"
1/
32
9'-0" CLG
W1 8 3/8"

"
1' - 10 1/4" 4' - 2 3/4"
1' - 7 5/16" DINING ROOM
9' - 9" 1' - 9 15/16" 3' - 1"
9'-0" CLG FRZ

3' - 5 9/16"
W3
3
5 1/2" 3 1/2" 3 1/2" 3 1/2" 5' - 1"

1
6"

5' - 0 3/8" 3' - 9" 6' - 0 1/2" 1' - 7 1/4" 3' - 5 3/4"

3 1/2"
6' - 1"
2' - 5 1/2"

3' - 5 1/4" W.I.C.


3 MIRROR
B
5' - 0 1/2"

3' - 11 11/16" 1' - 7 1/4"


BATH 3 S&P
2' - 7"
35' - 6"

2' - 1" MIRROR

5' - 10 7/16"
3 3

5' - 6 15/16"
9'-0" CLG MECH. FLUE
CHASE W3
3 1/2"

1' - 7" 7' - 7" HANDRAIL PANTRY


DN LAUNDRY
3 11' - 1 1/8" BATH W/ SIX

5 1/2"
S&P
SHELVES

D
9'-0" CLG
CLOSET

A301
3 9'-0" CLG
4' - 1"

W.I.C. 8
1' - 8 1/4" 3' - 8" 1' - 8 1/4"
S&P

S&P

44' - 6"
3 1/2"
W2

2' - 0"
4' - 1"
1' - 10 1/2" 1' - 10 1/2"
3 1/2"

Main Level Plan


3 1/2"
3 1 1
ENTRY
W.I.C.

EGDT1100
9'-0" CLG W4
3
A201 3 4 A201
2' - 9 1/4" 2' - 10 3/4" 2' - 1" 5' - 5 1/2"

7' - 9 5/16"
LIVING ROOM

5' - 5"
5' - 8" 9'-0" CLG
11' - 5 1/4"

3' - 7" 3' - 2 1/2" W1


3 1/2" W2

7' - 1"
1 GARAGE
2
BEDROOM 2

21' - 11 1/16"
NOTE: 5/8" TYPE "X" GYP
BOARD TO BE USED
9'-0" CLG
THROUGHOUT GARAGE
BEDROOM 1
6' - 0"

1 9'-0" CLG
7"

2' - 0"

1
C

12' - 1 3/4"
13' - 0"
1 2
A301 A301

PROJECT TITLE:

SHEET TITLE:
7"
18

5' - 8 1/2" 5' - 8 1/2" 5' - 5" 5' - 5" 2' - 3 3/4" 8' - 3 3/4" 5' - 4 1/2" 10' - 5" 10' - 5"
GENERAL NOTES REV. # DESCRIPTION DATE

11' - 5" 10' - 10" 20' - 10"


1. IT IS THE RESPONSIBILTY OF THE GENERAL CONTRACTOR TO INSURE
7" 12' - 0" 7" 12' - 0" 7" 16' - 0" 7" 22' - 0" 7" THAT ALL PRODUCTS ARE INSTALLED PER MANUFACTURERS
RECOMMENDATIONS.
62' - 0" 2. IT IS THE OWNER OR CONTRACTORS RESPONSIBILTY TO TAKE
NECESSARY PRECAUTIONS TO PREVENT AGAINST THE BUILD-UP OF
MOISTURE OR MOLD.
3. CONSTRUCTION MATERIALS REFERENCED HEREIN ARE FOR EXAMPLE
PURPOSES ONLY AND MAY NOT COMPLY WITH LOCAL ZONING OR
SAFETY REGULATIONS. OWNER OR CONTRACTOR SHALL BE
RESPONSIBLE FOR THE FINAL CHOICE AND SELECTION OF ALL
PROJECT #: Project Number
CONSTRUCTION MATERIALS. DATE: Issue Date
4. ALL PENETRATIONS IN TOP OR BOTTOM PLATES FOR PLUMBING OR DRAWN BY: Author
D ELECTRICAL RUNS ARE TO BE SEALED. SEE SHEET 001 FOR ADDITIONAL CHECKED BY: Checker
SPECIFICATIONS.
5. PROVIDE 1/2” WATERPROOF GYPSUM BOARD AROUND ALL TUBS, SCALE: As indicated
SHOWERS, AND SPAS.
6. VENT DRYER AND ALL FANS TO OUTSIDE AIR THROUGH VENT WITH
1
DAMPER.
A201
7. USE TEMPERED GLASS IN LOCATIONS WHERE REQUIRED BY CODE.
8. ALL DIMENSIONS ARE TO FACE OF STUD OR CONCRETE.

A1
9. SEE SHEETS SXXX & SXXX FOR STRUCTURAL DETAILS

1 1 Main Level A101 - NOTE


1/4" = 1'-0" 12" = 1'-0"

1 2 3 4 5
2 www.autodesk.com/revit
A301

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

No. Description Date

1
A301
2
A301

Owner
EGDT1100
Second Floor Plan
Project number Project Number
Date Issue Date
Drawn by Author
Checked by Checker

4/27/2022 20:55:46
1
T.O. Wall
1/4" = 1'-0"
A2
Scale 1/4" = 1'-0"
A201

www.autodesk.com/revit

2
A301

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
3 Address
A301 Address
Phone
Fax
e-mail

A201 3 4 A201

No. Description Date

1 2
A301 A301

Owner
EGDT1100
First Floor Reflected
Ceiling Plan
Project number Project Number
1
Date Issue Date
A201 Drawn by Author
Checked by Checker

4/27/2022 20:55:47
1
1 Main Level
1/4" = 1'-0"
A3
Scale 1/4" = 1'-0"
A201

2 www.autodesk.com/revit
A301

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

A201 3 4 A201

No. Description Date

1
A301
2
A301

Owner
EGDT1100
Second Floor
Reflected Ceiling Plan
Project number Project Number
1
Date Issue Date
A201 Drawn by Author
Checked by Checker

4/27/2022 20:55:47
1
T.O. Wall
1/4" = 1'-0"
A4
Scale 1/4" = 1'-0"
A201

2
www.autodesk.com/revit
A301

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

A201 3 4 A201

No. Description Date

2
A301

Owner
EGDT1100
Roof Plan
Project number Project Number
1
Date Issue Date
A201 Drawn by Author
Checked by Checker

4/27/2022 20:55:47
1 Roof Plan
1/4" = 1'-0"
A5
Scale 1/4" = 1'-0"
www.autodesk.com/revit

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

No. Description Date

Owner
EGDT1100
Building Sections
Project number Project Number
Date Issue Date
Drawn by Author
Checked by Checker

4/27/2022 20:55:48
A8
Scale
www.autodesk.com/revit

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

No. Description Date

Owner
EGDT1100
Building Sections
Project number Project Number
Date Issue Date
Drawn by Author
Checked by Checker

4/27/2022 20:55:48
A9
Scale
www.autodesk.com/revit

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

No. Description Date

Owner
EGDT1100
Wall Sections
Project number Project Number
Date Issue Date
Drawn by Author
Checked by Checker

4/27/2022 20:55:48
A10
Scale
www.autodesk.com/revit

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

No. Description Date

Owner
EGDT1100
Wall Sections
Project number Project Number
Date Issue Date
Drawn by Author
Checked by Checker

4/27/2022 20:55:48
A11
Scale
www.autodesk.com/revit

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

No. Description Date

Owner
EGDT1100
Details
Project number Project Number
Date Issue Date
Drawn by Author
Checked by Checker

4/27/2022 20:55:48
A12
Scale
www.autodesk.com/revit

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

No. Description Date

Owner
EGDT1100
Interior Elevations
Project number Project Number
Date Issue Date
Drawn by Author
Checked by Checker

4/27/2022 20:55:48
A13
Scale
www.autodesk.com/revit

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

No. Description Date

Owner
EGDT1100
Interior Details
Project number Project Number
Date Issue Date
Drawn by Author
Checked by Checker

4/27/2022 20:55:48
A14
Scale
Door Schedule
Door Door Door
Number Type Size

1 19 32" x
80
1 19 32" x
80 www.autodesk.com/revit
1 19 32" x
80
2 21 36" x
80 Consultant
Address
3 38 30" x Address
80" Phone
Fax
3 38 30" x e-mail
80"
3 38 30" x Consultant
80" Address
Address
3 38 30" x Phone
80" Fax
e-mail
3 38 30" x
80"
Consultant
3 38 30" x Address
80" Address
Phone
3 38 30" x Fax
80" e-mail
3 38 30" x
80" Consultant
Address
3 38 30" x Address
80" Phone
Fax
4 18 28" x e-mail
80"
5 20 72" x Consultant
80" Address
6 19 32" x Address
Phone
80 Fax
8 39 36" x e-mail
80"
9 19 32" x
80
10 38 30" x
80"
11 38 30" x
Window80"
Schedule
12 38
Ty Rough 30" x
pe Opening 80" Hea
M
13 38 30" x d
ar Wid Hei 80" Heig
k th 38
15 ght 30"Type
x ht No. Description Date
80"
16 4' - 6'
1 19- Window-Casem
32" x <vari
80
9" 0" ent-Double es>
18 1' - 6'
2 24- Fixed
192'' 7' -
4" 0" x 84'' 0"
21 2' - 3'
3 38- Window-Casem
30" x 7' -
80"
10" 0" ent-Double 0"
23 38 30" x
80"
24 38 30" x
80"
26 38 30" x
80"
28 38 30" x
80"

Owner
EGDT1100
Schedules
Project number Project Number
Date Issue Date
Drawn by Author
Checked by Checker

4/27/2022 20:55:49
A15
Scale
2
A301

1 2 3 4 5
Asphalt Shingle on Wood Truss
Asphalt Shingle on Wood Truss

12
12
12 6
6
6
A TOP PLATE TOP PLATE
20' - 4 3/8"

20' - 4 3/8"
9' - 1 1/8" 9' - 1 1/8"
1' - 0" 1' - 0"
TYP. TYP.

3
Board & Batten
3
A301 1 1 1
Board & Batten 2

18
Main Floor
0' - 0" Main Floor
0' - 0"
Foundation Foundation
-1' - 2 1/8" -1' - 2 1/8"
Grade
Grade -2' - 0"
3 -2' - 0"
T.O. FOOTING 2 T.O. FOOTING 2
-4' - 6" 1 1 -4' - 6"
Concrete
Concrete
Concrete 3 Basement
-8' - 10 1/8"
3 Basement T.O. Footing
-8' - 10 1/8" -9' - 2 1/8"
T.O. Footing
B -9' - 2 1/8"
2
3 Left A301
1/4" = 1'-0" Front
1
1/4" = 1'-0"
2
A301
Asphalt Shingle on Wood Truss

Exterior Elevations
Asphalt Shingle on Wood Truss

EGDT1100
12

TOP PLATE TOP PLATE


20' - 4 3/8"

20' - 4 3/8"
9' - 1 1/8" 9' - 1 1/8"
1' - 0" 1' - 0"
TYP. TYP.

3 3
3 Board & Batten
1 A301 1 1
Board & Batten 5
C
28 Main Floor Main Floor
0' - 0" 0' - 0"
Foundation Foundation

PROJECT TITLE:
-1' - 2 1/8" -1' - 2 1/8"

SHEET TITLE:
Grade Grade
-2' - 0" -2' - 0"
T.O. FOOTING 2
-4' - 6" 1 1 1
Concrete
REV. # DESCRIPTION DATE

3 Basement
3 Basement -8' - 10 1/8"
-8' - 10 1/8"
T.O. Footing
T.O. Footing -9' - 2 1/8"
-9' - 2 1/8"

Right
4
1/4" = 1'-0"

ELEVATION NOTES 2 Back


2
A301 PROJECT #: Project Number
1/4" = 1'-0"
DATE: Issue Date
MATERIALS: ROOF DRAINAGE: ROOF SHEATHING NOTES:
• IT IS THE OWNER OR CONTRACTOR’S RESPONSIBILITY TO TAKE THE NECESSARY PRECAUTIONS TO • COLLECT AND DISCHARGE ALL ROOF DRAINAGE TO THE GROUND SURFACE AT LEAST 5 FEET FROM • ROOF SHEATHING SHALL BE 7/16” APA RATED SHEATHING WITH A SPAN RATING OF 32/16. NAIL WITH DRAWN BY: Author
D PREVENT AGAINST THE BUILD-UP OF MOISTURE OR MOLD. FOUNDATION WALLS OR TO AN APPROVED DRAINAGE SYSTEM 8d NAILS AT 6” O.C. AT ALL PANELS ENDS, SUPPORTED EDGES, TOP OF SHEAR WALLS AND ALL CHECKED BY: Checker
• CONSTRUCTION MATERIALS REFERENCED HEREIN ARE FOR EXAMPLE PURPOSES ONLY AND MAY NOT ROOF DESIGN: BLOCKING. 8d NAILS AT 12” O.C. ALONG INTERMEDIATE FRAMING MEMBERS. LAY SHEATING WITH SCALE:
COMPLY WITH LOCAL ZONING OR SAFETY REGULATIONS • TRUSSES SHALL BE DESIGNED FOR 40 PSF LIVE LOAD. FACE GRAIN AT RIGHT ANGLES TO FRAMING WITH END JOINTS STAGGERED. As indicated
• OWNER OR CONTRACTOR ARE RESPONSIBLE FOR THE FINAL CHOICE AND SELECTION OF ALL • DESIGN TRUSSES TO LIMIT DEFLECTION TO L/360. • BLOCK TRUSSES/JOISTS SOLID AT ALL BEARING POINTS.
CONSTRUCTION MATERIALS • CHECK DIMENSIONS WITH ARCHITECTURAL DRAWINGS. TRUSS MANUFACTURER IS RESPONSIBLE TO ROOF VENTILATION:
FLASHING TO BE INSTALLED: PROVIDE WEB AND CHORD MEMBERS TO SATISFY LOAD REQUIREMENTS. • PROVIDE RIDGE VENTS AND SOFFIT VENTS AS REQUIRED BY CODE.
• AT ALL WALL AND ROOF INTERSECTIONS. • TRUSS MANUFACTURER SHALL SUBMIT CALCULATIONS AND SHOP DRAWINGS FOR APPROVAL BY
• WHEREVER THERE IS A CHANGE IN ROOF SLOPE OR DIRECTION. ENGINEER.

A201
• AROUND ALL ROOF OPENINGS. • VERIFY HEEL HEIGHTS ON TRUSSES. ALL HEEL HEIGHTS MAY NOT BE THE SAME.
ICE PROTECTION: • WALL HEIGHTS AT RAFTERED AREAS MAY NEED TO BE ADJUSTED UP OR DOWN TO MATCH HEELS AT
• (2) LAYERS OF UNDERLAYMENT CEMENTED TOGETHER AND EXTENDED FROM EAVE'S EDGE TO POINT TRUSSED AREAS SO FASCIA LINES MATCH UP. VERIFY HEIGHTS W/ TRUSS MANUFACTURER.
AT LEAST 24" INSIDE THE EXTERIOR WALL LINE
A201 - NOTES
12" = 1'-0"
1 2 3 4 5
1 2 3 4 5

235# ASPHALT SHINGLES OVER 30#


FELT W/ FIRST COURSE ICE SHIELD
DOUBLE 2"x SOLID 15/32" APA RATED OSB SHEATHING
STARTER
BLOCKING
COURSE PRE-ENGINEERED
GUTTER, MANUFACTURED
FASCIA & ROOF TRUSS
DRIP EDGE TOP PLATE
9' - 1 1/8"
SOFFIT &
TRIM- VENTS
A WHERE R-32 INSULATION
REQUIRED FINISHED CEILING
DOUBLE 1/2" GYP WALL
2"x6" TOP BOARD 15/32" APA
PLATE RATED OSB
SHEATHING
SIDING Pre-Engineered
Manufactured Roof Truss
9' - 1 1/8"

BOARD & TOP PLATE


BATTEN GUTTER, Double 2x6 Top Plate 9' - 1 1/8"
SIDING FASCIA &
15/32" APA R-19 INSULATION MIN. DRIP EDGE
RATED OSB 2"x6" STUDS @
SHEATHING 16" O.C. 15/32" APA
VAPOR BARRIER RATED OSB
MOISTURE SHEATHING R-19 INSULATION MIN.
BARRIER 2"x6" SOLE PLATE
2"x PRESSURE 3/4" T&G FLOOR 2x6 Wall Studs @ 16" O.C.
TREATED SILL SHEATHING
PLATE W/ Main Floor 2x6 Sole Plate
0' - 0" Floor Joist
VARIES

1/2"X10" Main Floor


ANCHOR 1 1/8" RIM JOIST- Rim Joist 0' - 0"
MATCH JOIST DEPTH Mudsill
BOLT @ 32"
O.C. Double 2x4 Top Plate
FINISH
GRADE 2x4 Wall Studs @ 16" O.C.
(2) COATS 1/2" GYPSUM R-13 INSULATION MIN.
B ASPHALT WALL BOARD
EMULSION
REINFORCE
W/ #4 BARS-
8' - 0" Forms

SEE 2x4 Sole Plate 3 Basement


8" FOUNDATION WALL 8" Concrete -8' - 10 1/8"
STRUCTUAL
NOTES FOR 2"x WALL
R-13 INSULATION MIN. 4" Concrete Slab
SPACING
VAPOR BARRIER 20" Concrete Footings
#4 BENT 4" CONCRETE SLAB
DOWELS @ W/ VAPOR BARRIER.

EGDT1100
24" REINFORCE W/

Sections
CONTINUOUS 6"x6"-#10 WIRE
MESH Section 2
(2) #4 BARS 2
1/4" = 1'-0"
CONTINUOUS
4"

T.O. Footing
10"

-9' - 2 1/8"
Undisturbed Remove all
Earth forms prior to
1' - 8"
backfill
Remove roots for a
1 1/2"

min. depth of 12"


under all footings

Section 1
1
C 1/2" = 1'-0"

Main Floor
3 1/2" 0' - 0"

PROJECT TITLE:

SHEET TITLE:
Type X Gyp. STAIR/HANDRAIL NOTES
• MIN TREAD DEPTH = 10"
• MAX RISER HEIGHT = 7 3/4"
REV. # DESCRIPTION DATE
• MIN HEAD CLEARANCE = 6'-8"
7' - 6 31/32"

• MAX RISER/TREAD VARIANCE = 3/8"

Head Clearance
• HANDRAIL HEIGHT IS 34" TO 38"

6' - 8"
• USE 5/8" TYPE "X" GYP BOARD AT ALL ENCLOSED AREAS UNDER STAIRS.
• HANDRAILS MAY ENCROACH UPON STAIR WIDTH A MAX OF 4 1/2".
• HANDRAILS REQUIRED ALONG STAIRS W/ (2) OR MORE TREADS.
• PROVIDE GAURDRAILS AT LANDINGS, BALCONIES, AND/OR DECKS LOCATED MORE THAN 30"
Height 34-38"

VERTICALLY TO FLOOR/GRADE BELOW.


• BALLUSTERS SHALL BE PLACED SO A 4" SPHERE CANNOT PASS THROUGH.
7 3/4" Max

A301 - NOTES
10" Min 12" = 1'-0"
PROJECT #: Project Number
DATE: Issue Date
12' - 0" 3 Basement DRAWN BY: Author
D -8' - 10 1/8"
CHECKED BY: Checker
2x4 Kickblock
SCALE: As indicated

3 Section 3
1/2" = 1'-0"

A301
1 2 3 4 5
1 2 3 4 5

N 0° 00' 26" W
144.00'

12' - 0"
A
1' - 0"

46' - 5 27/32"
SETBACK
46' - 7 3/8"

69' - 9 1/2" 12' - 2 1/2"

SETBACK
FENCE
N 89° 56' 32" W

UTILITES METERS
S 89° 56' 32" E
116.00'

116.00'
B

FENCE
FENCE

EGDT1100

Site Plan
SITE NOTES:
10' - 0"

• SLOPE GRADE A MINIMUM OF 2% FROM FOUNDATION IN ALL DIRECTIONS


• ALL EXTERIOR FLATWORK SHALL BE NORMAL WEIGHT CONCRETE WITH A COMPRESSIVE STRENGTH
33' - 10 5/8"

EQUAL TO AT LEAST 3,000 PSI WITHIN 28 DAYS AFTER POURING


SETBACK

70' - 0 5/16" 12' - 0"


• PROVIDE CONTROL JOINTS IN SLABS AT A MAXIMUM OF 10’-0” O.C. EACH DIRECTION OR AS SH
SETBACK SETBACK

SETBACK
25' - 0"
C101 - NOTES
12" = 1'-0"
12' - 0"

10' - 0"

P.U.E
C
S 0° 00' 26" E
144.00'
SIDEWALK

PROJECT TITLE:

SHEET TITLE:
REV. # DESCRIPTION DATE

Site Plan
1
1" = 10'-0"

PROJECT #: Project Number


DATE: Issue Date
DRAWN BY: Author
D CHECKED BY: Checker
SCALE: As indicated

C1
1 2 3 4 5
A201

www.autodesk.com/revit

2
A301

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax

3
e-mail

Consultant
Address
Address
Phone
Fax
e-mail
3 WH +44"
GFI
GB FD
Consultant
Address
+44" +44" Address
GFI GFI Phone
Fax
e-mail

3
3

Consultant
3 UP
Address
A301 3 Address
Phone
Fax
e-mail

A201 3 4 A201

No. Description Date

1 2
A301 A301

Owner
EGDT1100
Basement Electrical
Plan
Project number Project Number
1
Date Issue Date
A201 Drawn by Author
Checked by Checker

4/27/2022 20:56:03
1
4 Basement Electrical
1/4" = 1'-0"
E0
Scale 1/4" = 1'-0"
1 2 3 4 5

A201

ELECTRICAL SYMBOLS LEGEND


A301
GFI
WP

P
3 3 3 3
+44" SINGLE-POLE SWITCH
GD +44"
DW GFCI GFCI
3 THREE-WAY SWITCH

P
TO FAN
R
+44" CEILING-MOUNTED LIGHT FIXTURE
TO FAN GFCI
WALL-MOUNTED LIGHT FIXTURE
+44"
GFI

3
+44"
CEILING FAN
R
GFCI
+44"
GFI DUPLEX OUTLET - 110 VOLTS
+44"
TV CH 220 VOLT OUTLET FOR OVENS,
3
WATER HEATERS, CLOTHES
DRYERS, WELDERS, &CT.
+44"
+44" SMOKE DETECTOR
TO FAN 3 3
GFI
B P PHONE HARD LINE OUTLET

P
3
+44"
GFI PC
PC HARD LINE OUTLET
3

3 DN TV
CABLE CONNECTION OUTLET
TO FAN
A301
CH DOORBELL CHIME

3 3
3
PC
GFI R RECCESSED CAN LIGHT

Main Level Electrical


TV
3 WP

SPECIAL OUTLET

EGDT1100
A201 3 4 A201

3
ELECTRICAL NOTES
3 On Ceiling
BUZZER GFI 1. ELECTRICAL PLANS ARE FOR LAYOUT PURPOSES ONLY. CONSULT WITH
WP A LICENSED ELECTRICIAN FOR EXACT SPECIFICATIONS TO MEET LOCAL
& GOVERNING CODES.
2. WORK IS TO COMPLY WITH ALL CODES AND ORDINANCES.
3. ALL OUTLETS ARE TO BE +44” ABOVE FLOOR LINE IN THE FOLLOWING
AREAS: PANTRY, BATHROOMS AND KITCHENS ABOVE COUNTER TOPS,
AND GARAGES.
C 4. GROUND FAULT INTERRUPT (GFI) OUTLETS ARE REQUIRED IN THE
FOLLOWING LOCATIONS: BATHROOMS, GARAGES, EXTERIOR WALLS,
1 2
SEE A100 (BASEMENT) FOR CIRCUT BREAKERS UNFINISHED AREAS, KITCHEN ISLAND, AND WITHIN 5’-0” OF SINKS.
A301 A301 5. PROVIDE A SEPARATE CIRCUIT FOR MICROWAVE OVEN.
6. PROVIDE A SEPARATE CIRCUIT FOR OUTLETS IN KITCHEN ISLAND.

PROJECT TITLE:
7. ALL EXTERIOR OUTLETS SHALL BE ENCLOSED IN A WEATHERPROOF

SHEET TITLE:
PROTECTIVE COVER.
8. EXTERIOR SPOTLIGHTS TO BE ON PHOTOELECTRIC CELL WITH TIMER
9. ALL RECESSED LIGHTS IN EXTERIOR CEILINGS TO BE INSULTION COVER
RATED.
10.ELECTRICAL OUTLET PLATE GASKETS SHALL BE INSULATED ON
RECEPTACLE, SWITCH, AND ANY OTHER BOXES IN EXTERIOR WALL.
REV. # DESCRIPTION DATE
11.VERIFY ALL ELECTRICAL LOCATIONS WITH OWNER.
12.CONSULT OWNER FOR EXACT PLACEMENT OF BOXES FOR
AUDIO/VISUAL EQUIPMENT.
13.CABINET LIGHTING IS TO BE SWITCHED AND INCLUDES LIGHTING INSIDE
AND UNDERNEATH UPPER CABINETS. VERIFY WITH OWNER.
14.BRACE LIGHT FIXTURES IN BEDROOMS, GREAT ROOMS, FAMILY/LIVING
ROOMS, DENS, MUSIC ROOMS, ETC. FOR CEILING FANS.
15.VERIFY THAT PANEL IS SIZED LARGE ENOUGH FOR ADDITION. INSTALL
ADDITIONAL SUB PANEL AS REQUIRED. DESIGN BUILD BY ELECTRICAL
CONTRACTOR.
16.CONTRACTOR TO INSTALL OWNER SPECIFIED FIXTURES.
PROJECT #: Project Number
DATE: Issue Date
DRAWN BY: Author
D CHECKED BY: Checker
SCALE: As indicated

A201

1
2 Main Level Electrical
1/4" = 1'-0"
E1
1 2 3 4 5

E101 - NOTES
12" = 1'-0"
A201

2 www.autodesk.com/revit
A301

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

A201 3 4 A201

No. Description Date

1
A301
2
A301

Owner
EGDT1100
Second Floor Electrical

1
Project number Project Number
Date Issue Date
A201
Drawn by Author
Checked by Checker

4/27/2022 20:56:09
1
Second Floor Electrical
1/4" = 1'-0"
E2
Scale 1/4" = 1'-0"
1 2 3 4 5
PLUMBING NOTES: CONCRETE & EXCAVATION NOTES:
GENERAL NOTES INDEX TO DRAWINGS:
GENERAL PLUMBING NOTES: GENERAL CONCRETE & EXCAVATION NOTES:
GENERAL DESIGN NOTES:
1. PLUMBING SHALL NOT BE “FLAG POLED”. MAIN PLUMBING STACKS SHALL RUN UNDIMINISHED IN 1. ALL CONCRETE WORK SHALL BE PLACED, CURED, STRIPPED, AND PROTECTED AS DIRECTED BY
1. STRUCTURAL AND FRAMING MEMBERS INDICATED ARE BASED ON SPECIES OF SIZE (3” MIN.) AND AS DIRECT AS POSSIBLE FROM THE MAIN DRAIN TO THE OPEN AIR ABOVE THE ROOF. ARCHITECTURAL SET
SPECIFICATIONS AND ACI STANDARDS/ PRACTICES.
LUMBER THAT SATISFY THE SPAN. 2. PLUMBING VENTS SHALL BE 2’-0” ABOVE OR 10’-0” AWAY FROM ALL AIR INTAKE OPENINGS. 2. BEFORE POURING CONCRETE CHECK WITH ALL TRADES TO INSURE PROPER PLACEMENT OF ALL
2. TRUSSES SHALL BE DESIGNED BY LOCAL MANUFACTURERS G000 COVER SHEET
C101 SITE PLAN OPENINGS, SLEEVES, CURBS, CONDUITS, BOLTS, INSERTS, ETC.
3. GENERAL CONTRACTOR TO CONFIRM THE SIZE, SPACING, AND SPECIES OF ALL BATHROOM NOTES: 3. CONTRACTOR IS RESPONSIBLE FOR ALL SHORING AND FORMWORK.
FRAMING AND STRUCTURAL MEMBERS AND IS TO VERIFY ALL MEASUREMENTS ON A100 BASEMENT FLOOR PLAN
A101 MAIN LEVEL FLOOR PLAN 4. ALL COLUMNS, RETAINING WALLS, AND EXTERIOR FLATWORK SHALL BE NORMAL WEIGHT CONCRETE
JOB SITE. 1. SHOWER COMPARTMENTS SHALL HAVE AT LEAST 900 SQ. INCHES OF FLOOR AREA AND BE OF SUFFICIENT SIZE WITH A COMPRESSIVE STRENGTH EQUAL TO AT LEAST 3,000 PSI WITHIN 28 DAYS AFTER POURING. THE
A201 EXTERIOR ELEVATIONS
A4. ANY STRUCTURAL OR FRAMING MEMBERS NOT INDICATED ON THE PLANS ARE
TO BE SIZED BY THE CONTRACTOR.
TO INSCRIBE A CIRCLE WITH A DIAMETER NOT LESS THAN 30”.
2. HINGED SHOWER DOORS SHALL OPEN OUTWARD.
A202 EXTERIOR ELEVATIONS WATER/CEMENT RATIO SHALL BE NO GREATER THAN 0.44 AND SLUMP SHALL BE 4 INCHES OR LESS.
5. ALL FOOTINGS (2,500 PSI), FOUNDATIONS (3,000 PSI), AND INTERIOR SLABS ON GRADE (3,000 PSI) SHALL
5. PROVIDE NECESSARY BRIDGING AS REQUIRED BETWEEN FLOOR JOISTS 3. SHOWERS SHALL BE FINISHED TO A HEIGHT NOT LESS THAN 72” ABOVE THE FLOOR. A301 SECTIONS
E100 BASEMENT ELECTRICAL BE NORMAL WEIGHT CONCRETE WITH A COMPRESSIVE STRENGTH AS NOTED WITHIN 28 DAYS AFTER
6. LIVE LOADS, DEAD LOADS, WIND LOADS, SNOW LOADS, LATERAL LOADS, AND 4. 1/2” WATER RESISITANT GYPSUM WALL BOARD/CEMENT BOARD TO BE USED AT TUB/SHOWER AREAS. POURING. THE WATER/CEMENT RATIO SHALL BE NO GREATER THAN 0.50 AND SLUMP SHALL BE 4 INCHES OR
EARTHQUAKE LOADS ARE TO BE DETERMINED BEFORE CONSTRUCTION BY A 5. ALL SHOWER ENCLOSURES AND DOORS TO BE CONSTRUCTED WITH TEMPERED GLASS. E101 MAIN LEVEL ELECTRICAL
S100 FOOTING & FOUNDATION PLAN LESS.
LICENSED ENGINEER AND ADJUSTMENTS TO PLANS MADE ACCORDINGLY. 6. PROVIDE ANTI-SCALD SHOWER VALVE ON ALL SHOWER AND TUB/SHOWER COMBOS. 6. ALL METAL REINFORCEMENT SHALL BE DEFORMED TYPE BARS (EXCEPT #2 BARS) AND SHALL CONFORM
7. ALL EXTERIOR WALLS, INCLUDING GARAGES ARE TO HAVE A MIN OF 7/16" RIGID 7. BATHROOMS, WATER CLOSET COMPARTMENTS, AND OTHER SIMILAR ROOMS SHALL BE PROVIDED WITH S101 ROOF FRAMING PLAN
TO THE REQUIREMENTS OF THE STANDARD SPECIFICATIONS ASTM A615 GRADE 60. BEAM AND COLUMN TIE
SHEATHING. WINDOWS OF NOT LESS THAN 3 SQ. FEET, ONE HALF OF WHICH MUST BE OPENABLE. (IF NO WINDOWS, A REINFORCEMENT SHALL CONFORM TO THE REQUIREMENTS OF THE STANDARD SPECIFICATION ASTM A615
8. ALL EXTERIOR WALLS ARE DIMENSIONED TO FACE OF STUD. MECHANICAL VENTILATION SYSTEM SHALL BE REQUIRED. THE MINIMUM VENTALATION RATE SHALL BE 50 CFM FOR GRADE 60.
9. ALL INTERIOR DIMENSIONS ARE FROM FACE OF STUD TO FACE OF STUD. CONTINUOUS VENTALATION). 7. WELDED WIRE FRABRIC SHALL CONFORM TO ASTM A185 AND SHALL HAVE A MINIMUM LAP OF 8”.
10. DIMENSIONS TAKE PRECEDENCE, DO NOT SCALE DRAWINGS, VERIFY ALL 8. THE FOLLOWING CLEARANCES MUST BE PROVIDED: 24 INCHES IN FRONT OF SHOWER; 21 INCHES IN FRONT OF 8. ALL REINFORCEMENT SHALL BE DETAILED AND PLACED IN ACCORDANCE WITH ACI DETAILING MANUAL
DIMENSIONS BEFORE CONSTRUCTION. TOILETS AND CABINETS. TOILETS REQUIRE 30 INCHES MINIMUM CLEAR WIDTH. 315-77 AND ACI STANDARD 318-83.
11. VERIFY DEPTH OF FROST LEVEL FOR FOOTINGS WITH LOCAL GOVERNING 9. LAVATORY OR SINK MAXIMUM FLOW RATE IS 2.2 GPM, SHOWER IS 2.5 GPM, AND WATER 9. ALL SPLICES IN CONTINUOUS CONCRETE REINFORCING BARS SHALL LAP 30 BAR DIAMETERS. ALL
CODES. CLOSETS ARE 1.6 GPF. SPLICES SHALL BE MADE IN A REGION OF COMPRESSION UNLESS OTHERWISE SHOWN.
12. VERIFY SIZES OF FOOTING/FOUNDATION WITH LOCAL CODES, REGION, AND 10. LOCATE SINGLE TOWEL BARS AT 64 INCHES A.F.F. 10. ALL REINFORCEMENT BARS SHALL BE SECURELY ANCHORED AND SHALL BE SPACED FROM THE FORMS
BEARING CAPACITY OF SOIL. 11. ALL BATHROOMS AND LAUNDRY ROOMS TO HAVE WATER RESISTANT GYPSUM WALL BOARD. (UNLESS OTHERWISE SHOWN) AS FOLLOWS: 2 INCHES IN BEAMS AND COLUMNS, 1 INCH IN PROTECTED
WALLS AND SUSPENDED SLABS, 2 INCHES IN UNPROTECTED WALLS, AND 3 INCHES ABOVE BOTTOM AND
GENERAL CONSTRUCTION NOTES: SIDES OF FOOTINGS.
11. ALL OPENINGS IN CONCRETE WALLS SHALL BE REINFORCED WITH (2) #5 BARS EXTENDING A MINIMUM
1. VISITS TO THE JOB SITE BY A REPRESENTATIVE OF THE OF 2‘-0” BEYOND THE EDGE OF OPENING AT EACH FACE OF OPENING.
DESIGNER/ARCHITECT/ENGINEER DO NOT SUBSTITUTE APPROVAL OF THE WORK 12. FOR STEPS IN FOUNDATION GREATER THAN 2’-0”, WRAP CORNER WITH (2) #4 BARS EXTENDING 18" EACH
PERFORMED BY THE GENERAL CONTRACTOR OR HIS SUBCONTRACTORS AND ARE DIRECTION.
MERELY FOR THE PURPOSE OF OBSERVING THE WORK PERFORMED. 13. REINFORCE CONCRETE LINTELS (MAX SPAN 6 ‘-0”) WITH (2) #4 BARS TOP AND BOTTOM, 10 INCHES DEEP.
2. GENERAL CONTRACTOR SHALL NOTIFY DESIGNER/ARCHITECT/ENGINEER OF EXTEND REBAR OVER OPENINGS AT LEAST 24 INCHES BEYOND OPENING.
ANY DISCREPANCIES, OMISSIONS, OR CONFLICTS BETWEEN THE VARIOUS 14. ANY EARTH FILL TO SUPPORT CONCRETE FLOORS, WALKS, DRIVEWAYS, ETC. MUST BE COMPACTED TO
ELEMENTS OF THE WORKING DRAWINGS AND/OR SPECIFICATIONS BEFORE 90% OR TO LOCAL CODE IN WHICH CONSTRUCTION TAKES PLACE.
PROCEEDING WITH THE WORK INVOLVED. IN ALL CASES, UNLESS OTHERWISE 15. NO STUMPS, ROOTS, OR ORGANIC MATERIAL SHALL BE PRESENT IN SOIL AT THE AREA OF THE
B DIRECTED, THE MOST STRINGENT REQUIREMENTS SHALL GOVERN THE WORK TO
BE PERFORMED.
BUILDING.
16. CONTRACTOR SHALL BE RESPONSIBLE FOR LATERALLY SUPPORTING ALL RETAINING TYPE FOUNDATION
3. COMPLIANCE WITH CODES AND ORDINANCES GOVERNING THE WORK SHALL BE WALLS WHILE COMPACTING BEHIND WALLS AND UNTIL ALL SUPPORTING MEMBERS HAVE BEEN PLACED
ENFORCED BY THE GENERAL CONTRACTOR. (SUCH AS A FLOOR).
4. GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL PERMITS, INSPECTIONS, AND
FEES, ETC. REQUIRED BY LOCAL AND NATIONAL CODES AND ORDINANCES. FOOTINGS:
5. GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL PERFORM THEIR
TRADES AND DUTIES IN A MANNER CONFORMING TO THE PROCEDURES AND 1. FOOTINGS SHALL BE EXCAVATED TO A 30 INCH MINIMUM DEPTH SO AS TO PROVIDE FROST PROTECTION.
REQUIREMENTS AS ADOPTED BY THE LOCAL BUILDING OFFICIALS. VERIFY WITH LOCAL CODES.
6. GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS, DIMENSIONS AND 2. ALL FOOTINGS SHALL BEAR ON UNDISTURBED NATIVE SOIL OR ENGINEERED GRANULAR FILL COMPACTED
ELEVATIONS, ETC., AT THE SITE AND SHALL COORDINATE WORK PERFORMED BY TO 95% OF MAXIMUM DENSITY, BASED ON ASTM D 1557 METHOD OF COMPACTION. FILL SHALL BE PLACED IN
ALL TRADES. DO NOT SCALE DRAWINGS. LAYERS NOT TO EXCEED 6 INCHES DEPTH AFTER COMPACTION AND SHALL EXTEND DOWN TO EXISTING

EGDT1100
7. GENERAL CONTRACTOR SHALL COORDINATE THE WORK OF THE VARIOUS SOIL. FILL SHALL BE COMPACTED UNDER ALL CONCRETE WORK ON THE SITE.
TRADES TO EXPEDITE THE JOB IN A SMOOTH AND CONTINUOUS PROCESS.

COVER
8. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY AND FOUNDATION WALLS:
PROTECTION WITHIN AND ADJACENT TO THE JOB SITE.
9. GENERAL CONTRACTOR SHALL PATCH/REPAIR/REPLACE ANY AND ALL DAMAGE 1. 8 INCH CONCRETE FOUNDATION WALLS ON 10 INCH CONCRETE FOOTINGS UNLESS NOTED OTHERWISE.
TO OWNER'S PROPERTY CAUSED BY CONSTRUCTION PROCESSES. REINFORCEMENT BARS PLACED AS FOLLOWS: VERTICAL - #4 BARS (GRADE 60) AT 24 INCHES O.C. TO
10. TEMPORARY BRACING SHALL BE PROVIDED WHEN NECESSARY TO TAKE CARE EXTEND WITHIN 3 INCHES OF TOP. HORIZONTAL - (6) #4 BARS (GRADE 60) W/ ONE BAR WITHIN 4 INCHES OF
OF ALL LOADS TO WHICH THE STRUCTURE MAY BE SUBJECTED, INCLUDING WIND. TOP AND BOTTOM OF WALL. 1/2 INCH X 10 INCH J-BOLTS AT 32 INCHES O.C.
SUCH BRACING SHALL BE LEFT IN PLACE AS LONG AS REQUIRED FOR SAFETY, 2. FINISH GRADING SHALL BE DONE AS TO PROVIDE POSITIVE DRAINAGE AWAY FROM ALL BUILDING
AND/OR UNTIL ALL THE STRUCTURAL ELEMENTS ARE INSTALLED. FOUNDATIONS. A MINIMUM SLOPE OF 2% SHALL BE MAINTAINED FOR THE FIRST 10’-0” WITH 1% SLOPE
11. ADD 2X6 PLUMBING WALLS AS REQUIRED BY LOCAL CODE. THEREAFTER TO APPROVED DRAINAGE AREA.
12. 1/2" WATER RESISTANT DRYWALL AT SHOWER, TUBS, AND WHIRLPOOLS. 3. BITUMINOUS COATING MUST BE PLACED ON FOUNDATION WALLS BELOW GRADE ENCLOSING HABITABLE
13. 1/2" DRYWALL ON INTERIOR WALLS AND CEILINGS. SPACE.
14. 5/8" TYPE "X" FIRE RATED DRYWALL ON GARAGE WALLS AND CEILING. 4. TOP OF FOUNDATIONS WALLS TO BE A MINIMUM 8 INCHES ABOVE ADJACENT FINISHED GRADE.
15. EXHAUST FANS SHALL BE 100 CFM. RUN ALL EXHAUST DUCT TO THE OUTSIDE.
C16. VENT DRYER TO THE OUTSIDE WITH 4” METAL DUCTING, TERMINATION CAP.
17. IT IS THE OWNER OR CONTRACTOR'S RESPONSIBILITY TO TAKE THE
CONCRETE SLABS:
NECESSARY PRECAUTIONS TO PREVENT AGAINST THE BUILD-UP OF MOISTURE 1. ALL SUSPENDED SLABS AND BEAMS SHALL BE NORMAL WEIGHT CONCRETE WITH A COMPRESSIVE
OR MOLD. STRENGTH EQUAL TO AT LEAST 4,000 PSI WITHIN 28 DAYS AFTER POURING. THE WATER/CEMENT RATIO
18. CONSTRUCTION MATERIALS REFERENCED HEREIN ARE FOR EXAMPLE SHALL BE NO GREATER THAN 0.44 AND SLUMP SHALL BE 4 INCHES OR LESS.
PURPOSES ONLY AND MAY NOT COMPLY WITH YOUR LOCAL ZONING OR SAFETY 2. CONCRETE FLOOR SLABS, EXCEPT FOR THOSE IN UNHEATED ACCESSORY STRUCTURES, SHALL HAVE A

PROJECT TITLE:
REGULATIONS. OWNER OR CONTRACTOR SHALL BE RESPONSIBLE FOR THE FINAL VAPOR RETARDER CONSISTING OF A 6 MIL. (.006 INCH) POLYETHYLENE OR APPROVED VAPOR RETARDER

SHEET TITLE:
CHOICE AND SELECTION OF ALL CONSTRUCTION MATERIALS. WITH JOINTS LAPPED NOT LESS THAN 6 INCHES PLACED BETWEEN THE CONCRETE FLOOR SLAB AND BASE
19. WINDOWS, IF NOT NOTED, ARE ASSUMED TO BE HORIZONTAL SLIDERS. COURSE, OR THE PREPARED SUB-GRADE WHERE NO BASE COURSE EXISTS.
20. TEMPERED GLASS TO BE USED AS REQUIRED BY LOCAL CODE. 3. SLAB ON GRADE FLOORS AT EXTERIOR PERIMETER FOUNDATION WALLS THAT ARE ABOVE GRADE ARE
21. ALL EXTERIOR DOORS SHALL HAVE A FLOOR LANDING ON EACH SIDE OF THE REQUIRED TO BE INSULATED. ALSO, BETWEEN THE WALL AND THE END OF THE SLAB A THERMO- BREAK IS
DOOR. THE EXTERIOR LANDING SHALL NOT BE MORE THAN 71Ú2” LOWER THAN THE REQUIRED.
FLOOR LEVEL, PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING. 4. PROVIDE CONTROL JOINTS IN SLABS AT A MAXIMUM OF 10’-0” O.C. EACH DIRECTION OR AS SHOWN ON REV. # DESCRIPTION DATE
PLANS. POUR SLABS BETWEEN CONTROL JOINTS SO THAT ADJACENT POURS ARE STAGGERED. EXTERIOR
AND GARAGE FLOORS ONLY.

CONSTRUCTION COMPLETION NOTES MECHANICAL NOTES: G000 - C


NOTES
12" = 1'-
1. CURB, GUTTER, AND SIDEWALK AT FRONTAGE OF LOT SHALL BE INSTALLED 1. CONTRACTOR SHALL PROVIDE A MINIMUM OF 7’-0” HEADROOM IN ALL AREAS OF DWELLING,
AT THE TIME OF NEW INCLUDING UNDER HEAT DUCTS, PLENUMS, PLUMBING ITEMS, AND STRUCTURAL MEMBERS.
CONSTRUCTION. CURB, GUTTER, AND SIDEWALK MUST BE CLEAN AND IN NEW 2. JOINTS FOR HEATING DUCTS SHALL BE MECHANICALLY FASTENED BY MEANS OF AT LEAST (3)
CONDITION AT THE SCREWS EVENLY SPACED. SUPORT DUCTS WITH APPROVED METAL SUPPORTS.
TIME OF FINAL INSPECTION. 3. NATURAL VENTILATION EQUALLING 4% OF THE FLOOR AREA SHALL BE THROUGH WINDOWS,
2. ALL CONSTRUCTION DEBRIS SHALL BE REMOVED FROM SITE BY FINAL DOORS, LOUVERS, OR OTHER APPROVED OPENINGS TO THE OUTDOORS UNLESS AN APPROVED PROJECT #: Project Number
INSPECTION. AT NO TIME SHALL MECHANICAL VENTILATION SYSTEM IS PROVIDED CAPABLE OF PRODUCING 0.35 AIR CHANGES PER DATE:
CONSTRUCTION DEBRIS BE BURIED AT THE SITE. CONSTRUCTION DEBRIS Issue Date
HOUR IN THE ROOM OR A WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM IS INSTALLED.
DRAWN BY: Author
DSHALL BE SECURED AT ALL
STAGES OF CONTRUCTION TO PREVENT TRAVELING FROM THE JOB SITE.
4. PROVIDE COMBUSTION AIR FOR ALL FUEL-BURNING APPLIANCES AT A MINIMUM RATE OF 1 SQ.
INCH PER 3,000 BTU/HOUR INPUT. THE ONE OPENING MUST BE IN THE TOP 12 INCHES OF THE CHECKED BY: Checker
3. APPROVED NUMBERS SHALL BE PROVIDED FOR ADDRESS OF NEW BUILDING ROOM. SHOW A MINIMUM 1 INCH CLEARANCE AROUND EQUIPMENT AT SIDES AND REAR OF THE SCALE: 12" = 1'-0"
PLACED IN A POSITION APPLIANCE. A MINIMUM OF 6 INCHES CLEARANCE IN FRONT OF THE APPLIANCE, UNLESS
WHICH IS PLAINLY VISIBLE AND LEGIBLE FROM STREET AT FRONTAGE OF MANUFACTURERS INSTRUCTIONS DIFFER.
PROPERTY.
FIRE PROTECTION NOTES:
ELECTRICAL NOTES:

G000
1. PROVIDE FIRE BLOCKING AT STUD CAVITIES GREATER THAN 8’-0”.
1. ELECTRICAL PLANS ARE FOR LAYOUT PURPOSES ONLY. CONSULT WITH 2. SMOKE DETECTORS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDINGS
LICENSED ELECTRICIAN FOR EXACT SPECIFICATIONS TO MEET LOCAL & WIRING AND SHALL BE EQUIPPED WITH A BATTERY BACK-UP. DETECTORS SHALL BE
GOVERNING CODES. SEE SHEETS E100 & E101 FOR ADDITIONAL SPECIFICATIONS WIRED IN SERIES SO ALARM IS AUDIBLE IN ALL SLEEPING AREAS.
3. SMOKE DETECTORS ARE REQUIRED IN ALL BEDROOMS, ALL FURNACE ROOMS,
ABOVE EACH STAIR, IN EVERY CORRIDOR/HALLWAY, AND IN UNFINISHED AREAS OF
THE BASEMENT.
1 2 3 4 5

G000 - ELECTRICAL NOTES


12" = 1'-0"
G000 - CONSTRUCTION COMPLEATION
NOTES
12" = 1'-0"
1 2 3 4 5

62' - 0"

8" 60' - 8" 8"

6' - 7 1/8" 2 20' - 2 3/8" 3' - 6" 3' - 6" 15' - 2 3/4" 3' - 6" 3' - 6" 4' - 7 3/4"
A301
8"

8"
A BLOCK OUT
FOR WINDOW
BLOCK OUT
FOR WINDOW
BLOCK OUT
FOR WINDOW

11 7/8" TJI210
FORM AND POUR ALL
9 1/2" TJI110
12' - 6 3/4"

16' - 2 1/2"

@ 24" O.C.
@ 24" O.C.
INTERIOR FOOTINGS
(NO SHOVEL FOOTINGS)
15' - 6 3/4"

11 7/8" TJI210
4" CONCRETE SLAB W/ VAPOR

@ 24" O.C.
16' - 7"
BARRIER OVER 4" COMPACTED

11 7/8" TJI210
GRANULAR FILL

20' - 8 9/16"
@ 12" O.C.
20' - 5"
B1
BEARING WALL PLUM FOR
FLOOR DRAIN
BLOCK OUT 20"x10" CONT FOOTING
FOR WINDOW PLUMB FOR BEARING WALL W/(2) #4 REBAR (TYP)
9 1/2" TJI110

SHOWER & B1 DBL RIM


34' - 2"

@ 24" O.C.
9' - 6 1/2"

TOILET
37' - 6"

3 B1 UP

A301
B1

44' - 6"
BEARING WALL

8"
B

2' - 0"
B1 B1 B1
BLOCK OUT
BEARING WALL FOR SIDE DOOR
18' - 7 1/4"

9 1/2" TJI110
@ 24" O.C.
9' - 9"

Beam Schedule

UNEXCAVATED MARK SIZE AND TYPE


15' - 8 1/2"

9 1/2" TJI110
9 1/2" TJI110
11' - 3 3/4"

@ 24" O.C.
@ 24" O.C.

13' - 3 3/4"

9 1/2" TJI110

B1 (2) 2"x6" DF-L

Foundation Plan
@ 24" O.C.

No2
STEP B2 (2) 2"x8" DF-L

EGDT1100
21' - 9 7/16"
FTG/FND No2
4" CONCRETE SLAB W/ 6"x6" - #10

19' - 9 7/16"
BLOCK OUT WIRE MESH COVER OVER 4" B3 (2) 2"x10" DF-L
COMPACTED GRANULAR FILL No2
5' - 4"

FOR WINDOW
6' - 0"

B4 (2) 1-3/4"x9-1/2"
8"

BLOCK OUT
1.9E LVL
1' - 4"

FOR WINDOW
B5 (2) 1-3/4"x11-7/8"
1.9E LVL
8"

8"

1 2
A301 A301

BLOCK OUT FOR


GARAGE DOOR
C

8"
5' - 7 1/2"
Foundation 5' - 8 1/2" 5' - 4" 5' - 4" 16' - 0"
1
1/4" = 1'-0" FOOTING AND FOUNDATION NOTES:

PROJECT TITLE:
8" 11' - 4" 8" 10' - 8" 8" 16' - 0" 8" 20' - 8" 8"

SHEET TITLE:
12' - 0" 12' - 0" 16' - 0" 22' - 0" • ALL DIMENSIONS ARE TO FACE OF CONCRETE OR FACE OF STUD.
• 1500 P.S.F. SOIL BEARING PRESSURE ASSUMED FOR FOOTING DESIGN. IF DIFFERENT CONDITIONS ARE
ENCOUNTERED NOTIFY ENGINEER AND DESIGNER.
62' - 0" • PROVIDE TERMITE PROTECTION AS REQUIRED PER LOCAL CODE.
• ACTUAL FLOOR JOIST LAYOUT & SPACING BY ENGINEER/MANUFACTURER. REV. # DESCRIPTION DATE
• DO NOT PLACE ANY FOOTINGS ON DISTURBED OR UNSTABLE SOIL - OVER EXCAVATE AND EXTEND
FOOTING DEPTH.
• VERIFY DEPTH OF FROST LEVEL W/ LOCAL CODES FOR FOOTING DEPTH.
• DO NOT BACKFILL BASEMENT WALLS UNTIL FIRST FLOOR IS IN PLACE.
• PROVIDE POSITIVE DRAINAGE AWAY FROM ALL BUILDING FOUDATIONS. A MINIMUM SLOPE OF 2%
SHALL BE MAINTAINED FOR THE FIRST 10’-0” WITH 1% SLOPE THEREAFTER TO APPROVED DRAINAGE
AREA.

S100 - NOTES
12" = 1'-0"
PROJECT #: Project Number
DATE: Issue Date
DRAWN BY: Author
D CHECKED BY: Checker
SCALE: As indicated

S0
1 2 3 4 5
1 2 3 4 5

2
64' - 0"
A301

A B3 B3 B3 B3
WALL VENTS IN GABLE

WALL VENTS IN GABLE


CONTINOUS
B1 RIDGE VENT B1
37' - 6"

37' - 6"
RIDGE
GABLE TRUSS

GABLE TRUSS
B

B1

First Floor Framing Plan


VA

VA
EY
LL

LL
ROOFING NOTES:

LL
E

E
EY

Y
VA

EGDT1100
RIDGE
LL

B3
VA

RIDGE
• PROVIDE SCREENED ROOF VENTS PER CODE (1/300 VENT TO ATTIC SPACE)
• ROOF SHEATHING SHALL BE 7/16” APA RATED SHEATHING WITH SPAN RATING OF 32/16 NAILED WITH
(TYP)
1' - 0"

B3 8d NAILS AT 6” OC AT ALL PANELS ENDS, SUPPORTED EDGES, TOP OF SHEAR WALLS AND ALL
GIRDER TRUSS B3 B3
BLOCKING. 8d NAILS AT 12” OC ALONG INTERMEDIATE FRAMING MEMBERS. LAY SHEATING WITH
GIRDER TRUSS FACE GRAIN AT RIGHT ANGLES TO FRAMING WITH END JOINT STAGGERED.
RIDGE

B1
2' - 0"

10 1/2" • BLOCK JOISTS SOLID AT ALL BEARING POINTS.


2 3/4"

B3
B3 • TRUSSES SHALL BE DESIGNED FOR 40 PSF LIVE LOAD.
4' - 3"

GABLE TRUSS 4' - 0 3/4"


1' - 0"
1 B1 • DESIGN TRUSSES TO LIMIT DEFLECTION TO SPAN (INCHES) DIVIDED BY 360 MINIMUM.
8x12
2' - 3"

(TYP) • CHECK DIMENSIONS WITH ARCHITECTURAL DRAWINGS. TRUSS MANUFACTURER IS RESPONSIBLE TO


A301 POST
5x5 POST (TYP)

2 GABLE TRUSS PROVIDE WEB AND CHORD MEMBERS TO SATISFY LOAD REQUIREMENTS.
1' - 0"

9' - 0"
(TYP)
1' - 0"

• TRUSS MANUFACTURER SHALL SUBMIT CALCULATIONS AND SHOP DRAWINGS FOR APPROVAL BY

(TYP)
2' - 0"
A301
ENGINEER.
C
9' - 0"

1' - 0"

B5 S101 - NOTES
12" = 1'-0"
GABLE TRUSS

PROJECT TITLE:

SHEET TITLE:
12' - 0" 11' - 6" 7' - 7 1/2" 8' - 10 1/2" 24' - 0"

1 6 Roof Framing
1/4" = 1'-0" REV. # DESCRIPTION DATE

PROJECT #: Project Number


DATE: Issue Date
DRAWN BY: Author
D CHECKED BY: Checker
SCALE: As indicated

S1
1 2 3 4 5
www.autodesk.com/revit

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

No. Description Date

Owner
EGDT1100
Second Floor Framing
Project number Project Number
Date Issue Date
Drawn by Author
Checked by Checker

4/27/2022 20:56:21
S2
Scale
www.autodesk.com/revit

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

Consultant
Address
Address
Phone
Fax
e-mail

No. Description Date

Owner
EGDT1100
Roof Framing
Project number Project Number
Date Issue Date
Drawn by Author
Checked by Checker

4/27/2022 20:56:22
S3
Scale