1 Hardware
2
1 Hardware
Xc 2002 Control module - specs
3
4
5
6
Fuel level:
Fuel level is measured by means of a 0,5…4,5 VDC fuel level sender in the main fuel tank.
A negativ fuel level indicates an incorrect signal due to a sensor failure or wiring defect
Vessel pressure:
Vessel pressure is measured by means of a 0,5…4,5 VDC sender in the load valve manifold.
A negativ pressure indicates an incorrect signal due to a sensor failure or wiring defect
7
Battery voltage:
The voltage is measured at the voltage in of the controller
A too low value will case a “charge fail” warning
Service timers:
The counter countes down to “0” meaning that the maintenance is due
If not reset, a “service” warning will be displayed at every start-up
8
LOG list
Alarms list:
Displays all active alarms ( warnings & shutdowns).
Alarm list
2 Alarm(s)
Parameter:
Opens subview where different parameters can be viewed and modified
Parameter
SW version:
Shows version of currently loaded firmware
9
10
LOG list +
11
Alarm list +
2 Alarm(s)
12
Acknowledged alarm:
The alarm pop-up will disappear when pressing the BACK button.
Active alarms can be viewed by entering the Alarm list.
Remark:
“Sensor failure W” -> sensor failure, at compressor side, casing a Warning
“Sensor failure S” -> sensor failure, at compressor side, casing a Shut down
13
Extra Views +
14
15
Regulating pressure:
Regulating pressure is measured by a 0,5…4,5VDC sensor.
The value is used to control the engine speed
RegP 0.00bar
00305.6h
16
Parameter +
Language
Icons
Unit
C/bar C/bar F/psi
Auto NoLoad
No No Yes
ST1 Reset
No No Yes The navigation buttons allow the user to
No
ST2 Reset
No Yes
scroll trough the different parameters
Unit Type
1 1 10
Production Test
No selection
Diagnostics
Off Off On
17
Set language:
Language
Icons
Language
German
Language
Spanish
Acknowledge
Language
French
Language
Back to parameters. Italian
Language
Cyrillic
18
Set units:
Unit
F/psi
Acknowledge
Back to parameters.
19
Auto NoLoad
Yes
Acknowledge
Back to parameters.
20
ST1 Reset
Yes
Acknowledge
Back to parameters.
21
22
Diagnostics +
Off Off On Passw. 1999
Diagnostics
On
Acknowledge
Back to parameters.
Disable Diagnostics : switch diagnostics back to the OFF position, press STOP or start the unit.
23
8 Operation
START
24
8 Operation
STOP
25
8 Operation
AUTOMATIC
26
27
28
8. Disconnect PARUS
29