www.vishay.com
Vishay BCcomponents
DC Film Capacitors
MKT Radial Potted Type
FEATURES
• 15 mm to 27.5 mm lead pitch.
Supplied loose in box and taped on reel
• Material categorization:
for definitions of compliance please see
www.vishay.com/doc?99912
APPLICATIONS
Blocking and coupling, bypass and energy reservoir
Encapsulation Flame retardant plastic case and epoxy resin (UL-class 94 V-0)
C-value; tolerance; rated voltage; manufacturer’s symbol;
Marking
year and week of manufacturer; manufacturer’s type
Note
• For more detailed data and test requirements, contact dc-film@vishay.com
DIMENSIONS
l w
lt
P Ø dt
27.5 mm 1 3
10 4
100 5
Example:
104 = 10 x 10 = 100 nF
BFC2 373 XX YY Y
2222 (*) 373 XX YY Y
(*) Old ordering number
PREFERRED TYPES
TYPE PACKAGING LEAD CONFIGURATION
C-TOL. 100 V 250 V 400 V 630 V
Lead length ± 10 % 23 43 53 63
Loose in box
5.0 mm ± 1.0 mm ±5% 24 44 54 64
373
compact H (1) = 18.5 mm ± 10 % 27 47 57 67
Taped on reel (1) P0 = 12.7 mm
Reel diameter = 356 mm ±5% 28 48 58 68
Lead length ± 10 % 21 41 51
Loose in box
5.0 mm ± 1.0 mm ±5% 22 42 52
373
-
standard H (1) = 18.5 mm ± 10 % 25 45 55
Taped on reel (1) P0 = 12.7 mm
Reel diameter = 356 mm ±5% 26 46 56
Note
(1) For detailed tape specifications refer to packaging information: www.vishay.com/doc?28139
Wmax. = W + Δ
Eccentricity
Imax. = I + Δ CBA116
hmax. = h + Δ
Seating plane
SOLDERING
For general soldering conditions and wave soldering profile, we refer to the application note:
“Soldering Guidelines for Film Capacitors”: www.vishay.com/doc?28171
Storage Temperature
Tstg = -25 °C to +35 °C with RH maximum 75 % without condensation
C/C
(%)
(%)
1 4 b. 100 V series
c. 250 V series
d. 400 V and 630 V series d
2
0
max. c
0
-1 typical b
-2
-2
-4
min.
-3 -6
102 103 104 f (Hz) 105 - 60 - 20 20 60 Tamb (°C) 100
1.2 102
Impedance 40
0V
factor
1 (Ω) ;5
6n
101 F
25
0V
0.8 ;2
10 .2
0V µF
100 ;1
5µ
0.6 F
10-1
0.4
0.2 10-2
0.0 10-3
- 60 - 20 20 60 Tamb (°C) 100 104 105 106 107 f (Hz) 108
Max. DC and AC voltage as a function of temperature Impedance as a function of frequency
102 102
Compact size Compact size
AC Voltage
AC Voltage
(V)
(V)
47
0
nF
101 2. 101
2 47
15 µF 0
2. nF
µF 2
15 µF
µF
100 100
101 102 103 104 f (Hz) 105 101 102 103 104 f (Hz) 105
103 103
Compact size Compact size
AC Voltage
AC Voltage
(V)
(V)
102 102
15
0
1.0 nF
1
10 4.7 F 101 15
F 0n
1.0 F
4.7 F
F
Tamb ≤ 85 °C, 250 VDC 85 °C < Tamb ≤ 105 °C, 250 VDC
100 100
101 102 103 104 f (Hz) 105 101 102 103 104 f (Hz) 105
Max. AC voltage as a function of frequency Max. AC voltage as a function of frequency
103 103
Compact size Compact size
AC Voltage
AC Voltage
(V)
(V)
102 102
47
nF
47
1.5 0 nF 47
µF nF
101 101 47
1.5 0 nF
µF
Tamb ≤ 85 °C, 400 VDC 85 °C < Tamb ≤ 105 °C, 400 VDC
100 100
101 102 103 104 f (Hz) 105 101 102 103 104 f (Hz) 105
Max. AC voltage as a function of frequency Max. AC voltage as a function of frequency
103 103
Compact size Compact size
AC Voltage
AC Voltage
(V)
(V)
102 102
56
22 nF
1.0 0 nF 56
µF 22 nF
101 101 1.0 0 nF
µF
Tamb ≤ 105 °C, 630 VDC 85 °C < Tamb ≤ 105 °C, 630 VDC
100 100
101 102 103 104 f (Hz) 105 101 102 103 104 f (Hz) 105
Max. AC voltage as a function of frequency Max. AC voltage as a function of frequency
102 102
Standard size Standard size
AC Voltage
AC Voltage
(V)
(V)
33
0
nF
4. .0 n
7 F
1
nF
33
101 101
0
nF
4. .0 µ
7 F
1
nF
Tamb ≤ 85 °C, 100 VDC 85 °C < Tamb ≤ 85 °C, 105 VDC
100 100
101 102 103 104 f (Hz) 105 101 102 103 104 f (Hz) 105
103 103
Standard size Standard size
AC Voltage
AC Voltage
(V)
(V)
102 102
15
0n
F
1.0
4.7 µF 15
0n
101 µF 101 F
1.0
4.7 µF
µF
Tamb ≤ 85 °C, 250 VDC 85 °C < Tamb ≤ 105 °C, 250 VDC
100 100
101 102 103 104 f (Hz) 105 101 102 103 104 f (Hz) 105
Max. AC voltage as a function of frequency Max. AC voltage as a function of frequency
103 103
Standard size Standard size
AC Voltage
AC Voltage
(V)
(V)
102 102
47
nF
47
1.5 0 nF 47
µF nF
47
0n
1.5 F
101 101 µF
Tamb ≤ 85 °C, 400 VDC 85 °C < Tamb ≤ 105 °C, 400 VDC
100 100
101 102 103 104 f (Hz) 105 101 102 103 104 f (Hz) 105
Max. AC voltage as a function of frequency Max. AC voltage as a function of frequency
103 105
Dissipation factor
RC (s)
(x 10-4)
5
4
3 104
2
1
102
16
ΔT (°C)
12
0
- 60 - 20 20 60 T 100
amb (°C)
Thermocouple
The temperature is measured in unloaded (Tamb) and maximum loaded condition (TC).
The temperature rise is given by T = TC - Tamb.
To avoid radiation or convection, the capacitor should be tested in a wind-free box.
Example
C = 330 nF - 63 V used for the voltage signal shown in next drawing.
UP-P = 40 V; UP = 35 V; T1 = 100 μs; T2 = 200 μs
The ambient temperature is 35 °C
Checking conditions:
1. The peak voltage UP = 35 V is lower than 63 VDC
2. The peak-to-peak voltage 40 V is lower than 22 x 40 VAC = 113 UP-P
3. The voltage pulse slope (dU/dt) = 40 V/100 μs = 0.4 V/μs
This is lower than 60 V/μs (see specific reference data for each version)
4. The dissipated power is 16.2 mW as calculated with fourier terms
The temperature rise for Wmax. = 3.5 mm and pitch = 5 mm will be 16.2 mW/3.0 mW/°C = 5.4 °C
This is lower than 15 °C temperature rise at 35 °C, according figure “Max. allowed component temperature rise”
5. Not applicable
6. Not applicable
Voltage Signal
Voltage
UP
UP-P
Time
T1
T2
INSPECTION REQUIREMENTS
General Notes
Sub-clause numbers of tests and performance requirements refer to the “Sectional Specification, Publication IEC 60384-2 and
Specific Reference Data”.
4.10.6.2 Final measurements Voltage proof = URDC for 1 min within 15 min No breakdown of flash-over
after removal from testchamber
4.11.3 Final measurements Voltage proof = URDC for 1 min within 15 min No breakdown of flash-over
after removal from testchamber
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay's knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer's responsibility to validate that a particular product
with the properties described in the product specification is suitable for use in a particular application. Parameters provided in
datasheets and / or specifications may vary in different applications and performance may vary over time. All operating
parameters, including typical parameters, must be validated for each customer application by the customer's technical experts.
Product specifications do not expand or otherwise modify Vishay's terms and conditions of purchase, including but not limited
to the warranty expressed therein.
Hyperlinks included in this datasheet may direct users to third-party websites. These links are provided as a convenience and
for informational purposes only. Inclusion of these hyperlinks does not constitute an endorsement or an approval by Vishay of
any of the products, services or opinions of the corporation, organization or individual associated with the third-party website.
Vishay disclaims any and all liability and bears no responsibility for the accuracy, legality or content of the third-party website
or for that of subsequent links.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please
contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.