You are on page 1of 12

ECHELON, ECHELON Smart, Sentinel, Sentinel Analytics and FatSep are registered

trademarks or trademarks of FUJIFILM Healthcare Corporation in Japan and other


countries. Lumada is registered trademarks or trademarks of Hitachi, Ltd. in Japan and
other countries. Pentaho is a registered trademark or trademark of Hitachi Vantara LLC
in Japan and other countries.
●Specifications and physical appearance may change without prior notice. ●Please
refer to the "operation manual" and the related documents for appropriate use of this
product. ●DICOM is the registered trademark or trademark of the National Electrical
2-16-1, Higashi-Ueno, Taito-ku, Tokyo, 110-0015, Japan Manufacturers Association in the United States for its standards publications relating to
https: //www.fujifilm.com/fhc/en digital communications of medical information. ●The products is a CLASS 2 LASER
PRODUCT.

FCP-E511 Printed in Japan 2021-03-XK-(D)


ECHELON Smart heralds the dawn of
a new standard for 1.5T superconductive MRI.

The ECHELON Smart features a small footprint and limited cost, without

compromising diagnostic quality and speed.

Based on our proprietary technology, this system has opened up the

potential for 1.5T systems, providing superb image quality and superior

install flexibility inherited from permanent-magnet MRI systems.

ECHELON Smart offers new options for superconductive MRI.

ECHELON
Smart
CONTENTS
01 SmartCOMFORT
02 SmartQUALITY
03 SmartSPEED
04 SmartECO
05 SmartSPACE

1 2
0 1 S m a r t C O M FO R T SmartCOMFORT
OFF

Patient-friendly
Quiet Examination SmartCOMFORT
ON

Various technologies exist to reduce MRI imaging noise.


However, low-noise MRI systems often compromise
on image quality or extend imaging time, making them
unsuitable for routine use.
Other approaches need special hardware that prevents their
widespread acceptance.
Our SmartCOMFORT noise reduction technology reduces
the acoustic noise by up to 96%†.
† Varies with the imaging conditions.

Our noise reduction technology has minimal impact on image


contrast or imaging time.
With SmartCOMFORT, the gradient magnetic field pulse form has been changed and the
imaging parameters adjusted, keeping a balance between the imaging time, contrast, image
SN ratio, and spatial resolution to reduce any impact the noise reduction technology may have.

Changing the waveform of the gradient magnetic field changes


the frequency characteristics.

2 1
Gradient magnetic field strength

Gradient magnetic field strength

1.5 Trapezoidal 0.8 Trapezoidal


0.6
1 Triangular Triangular
0.4
0.5
0.2
0 0
0 0.5 1 1.5 2 2.5 0 500 1000 1500 2000 2500

96
Time (ms) Frequency (Hz)

Gradient magnetic field pulse forms and frequency components

Principle of imaging noise reduction


The gradient magnetic field waveform is given by the product of the applied current and
application time. This waveform also changes the sound quality.

SmartCOMFORT can be used together with the motion


artifact reduction technology, RADAR†. † RADial Acquisition Regime
REDUCTION

3
Example of RADAR + SmartCOMFORT image % 4
03 SmartSPEED
Reduction of
To t a l E x a m i n a t i o n T i m e
To boost your productivity, ECHELON Smart offers features
that streamline workflow and enhance throughput, such as
AutoPose and Parameter Guidance function for easy and fast
operation. Fast scan capabilities and robust scan techniques
to reduce re-scanning contribute to shorter scan times, and
on-console analysis functions reduce the transfer time of
data to the workstation. With the SmartSPEED feature, your
operational efficiency is improved.

Enter MRI room Exit MRI room [Smart] Exit MRI room [Conventional]

02 SmartQUALITY

MPR
n ca

ved
ng-

st s

-
Cur
ng
ce

obu
i
-

ition
Superb Image Quality Realized by

dan

e Re cessi
ame etting

ing,
nd r
Gui

der
Pos

an a

o
-

es
ter

n
S

se

t Pr
n

niqu
t sc
e
oPo
n

Sca
Slic
Sca
S o p h i s t i c a t e d Te c h n o l o g i e s

Fas

m
Pos
tech
Aut
Par

Volu
The advanced specification of MRI sub-systems makes the most important impact
[Smart]
on the delivery of image quality without compromise. ECHELON Smart is equipped
with powerful sub-systems which includes the SmartENGINE which supports high
quality imaging and high performance RF system to empower robust imaging
[Conventional]
technologies. Time

5 6
17
04 SmartECO
Ecological with
Economical Running Cost
Superconductive MRI systems generally command high running costs.
% LESS
This cost is mainly related to the high power consumption of the cooling system
necessary to maintain superconductivity.
ECHELON Smart is equipped with an energy saving function that can stop the
cooling system for a certain length of time during periods of non-use or on non-
consultation days.
This function effectively reduces the power consumption whilst maintaining zero
boiling off of the helium.
Moreover, as the heat emission from the cooling system itself also decreases
during these periods, the power consumption of its heat-dissipating unit is also cut.

05 SmartSPA CE
Small Footprint and
Flexible Layout
It is often a matter of concern whether there is sufficient
space in the equipment room for a superconductive MRI
system installation.
ECHELON Smart has an extended cable length between the
main MRI gantry and the power unit in the equipment room.
This enables flexible layouts that can remove some of the
hurdles faced when introducing an MRI system.

7 8
Attain "high image quality" and "high speed" in
clinical practice with the combination of
our applications, operations, and hardware.

Sma rt Sma rt
APPL I CAT I ON OPE RAT I ON
All Around RADAR Coil System
Plaque Imaging AutoPose
isoFSE User Interface
BeamSat TOF Suggestion UI
VASC-ASL
BSI Sma rt
HARDWARE
FatSep
SmartENGINE
H-Sinc
16ch Receiver System
TIGRE
High Performance
T2* RelaxMap / Gradient System
R2* RelaxMap
High Performance
RF System

ECHELON Sma rt

Smart
I M AGE GAL L E RY

CONTENTS

9 10
Application/ECHELON Smart

S m a rt
APPL I C ATI ON
Applications which enhance the usefulness of head and thoraco-abdominal images.

All Around RADAR SE T1WI


isoFSE
Combined use of RADAR in sequences required for High-definition 3D imaging made possible by
routine head examinations optimizing RF application patterns

isoFSE is a high-speed 3D imaging function for isovoxels. The flip


RADAR mitigates motion artifacts enhancing ease of use when
angles of refocus pulses of FSE are varied to suppress the influence
imaging with many sequences, all receiver coils, and arbitrary
from signal strength fluctuations of MultiEchoes and enable high-
cross-sections. RADAR can be used in combination with high-
definition 3D imaging. The optimization of these application patterns
speed imaging. ECHELON Smart supports TOF and GrE sequences RADAR OFF 2:24 RADAR ON 2:39
FSE T2WI results in high contrasts achieved with T1WI, T2WI, and FLAIR images.
and is compatible with the combined use of RADAR for most of the
The high spatial resolution volume data acquired in imaging can be Reconstruction available for any cross-section
sequences required for routine head examinations, thus realizing
used to reconstruct images of any cross-section in MPR processing.
"All Around RADAR."

[BeamSat pulse excitation chart [BeamSat pulse excitation profile]


All Around
RADAR
RADAR
RAPID
RADAR
BeamSat TOF † (schematic diagram)]

Greater visibility of hemodynamic changes, RF

FA
Many coils/oblique Compatible with
Free sequences high-speed imaging Compatible with TOF/GE for example, due to stenosis. Gx Y
T1W1 T2W1 FLAIR PDI DWI TOF T2*WI RADAR OFF 2:32 RADAR ON 2:42

[Routine head imaging] Newly added Addition of hemodynamic information to TOF Gy


X
Time
Pencil-beam type pre-saturation (BeamSat) pulses based on the High-precision control of pre-saturation Beam-form pre-saturation pulse realized
Effects of RADAR in TOF MRA and GrE T2*WI TOF MRA
pulses using the spiral-type two- by a high system performance
application of local excitation are used in TOF imaging to selectively
dimensional excitation method
RADAR has been applied to GrE sequences using a high-precision
suppress some of the blood flow signals required for identification of
signal correction technology. This has enabled the combined use of
the hemodynamics.
RADAR in all sequences required for routine head examinations.
RADAR OFF 4:28 RADAR ON 4:49
TOF MRA
If imaging is conducted with BeamSat pulses specified for a target
blood vessel, the flow signals of that vessel can be suppressed, and
the dominant region can be identified. BeamSat pulses can be set to
arbitrary positions and angles using a special GUI. The positions of
BeamSat pulses can be set freely with respect to a target vessel.

RADAR OFF 4:23 (without synchronization) RADAR ON 4:53 (without synchronization)


[Special GUI for BeamSat] BeamSat pulse setting example
In the BeamSat display, the continuous line on the left ICA
represents a nearer part and the broken SAG cross-section: Position contacting
line a part farther than the scanogram; nasal root/sella turcica
the hatched part is a cross-section between AX cross-section: Position contacting
a BeamSat and a scanogram. pyramid/clivus

Subtraction of images with and without BeamSat pulses can be


Plaque Imaging† RADAR-SE SIR Map 200
Hemorrhage
displayed in a reversed black-and-white image to visualize it as in
For diagnosis of plaque characteristics 150
Lipid
MR-DSA.
ROI 120
Diagnosis of carotid artery plaque characteristics requires an MR Fibrous
Reference Without BeamSat With BeamSat
image with high T1 contrast. 100
TR: 500 ms, TE: 15 ms
Asynchronous RADAR-SE method
MRI plaque imaging of the carotid artery Color map of the carotid artery plaque

The asynchronous RADAR-SE method By normalizing the ROI signal strength to


to which Radial Scan has been applied a reference, the SIR Map displays a color
maintains a constant TR without influence map of signal strength ratios. Applying
from pulsation, and can conduct imaging this to Plaque Imaging could facilitate
Subtraction image
with a high T1 contrast appropriate for diagnosis of the plaque characteristics.
(reversed black-and-white image)
diagnosis of plaque characteristics.

† Optional
11 12
Application/ECHELON Smart

Smar t
APPLICAT I O N

VASC-ASL (Veins and Arteries Sans Contrast-Arterial Spin Labeling) H-Sinc


Visualization of fast blood flow IR pulse OFF Fat suppression method resistant to non-uniform RF radiation
in renal arteries and portal veins
Uniform RF radiation is one element required to achieve a high fat
VASC-ASL is a non-contrast imaging method that can visualize fast IR pulse ON suppression effect. In general, achieving uniform RF radiation in a large
blood flow in the renal artery and portal vein in the abdomen. This FOV is difficult. H-Sinc applies more than one CHESS pulse to realize fat
feature visualizes blood flows labelled with IR pulses using the 3D BASG suppression, minimizing the impact from non-uniform RF radiation. A
Subtraction
sequence and does not require ECG/pulse wave synchronization. image stable fat suppression effect can be achieved even over a large range.
Selectively applying IR pulses upstream in the blood vessels to be
(a) Portal veins (b) Renal arteries
visualized and acquiring images when the blood flow is Null enables the RF
Examples of VASC-ASL images Conventional
CHESS method
incoming labelled blood flow to be visualized as Black Blood. Therefore,
GC
by capturing images twice with selective IR pulses ON and OFF and H-Sinc pulse part This sequence part
H-Sinc method
acquiring a subtraction image, blood flows labelled with IR pulses will be H-Sinc
Comparison of
remaining fat signals
Wide-range, stable fat suppression with H-Sinc

visualized as a high-intensity area.

TIGRE
BSI (Blood Sensitive Imaging)

Acquisition of clear images with high-precision fat suppression
Image acquisition by sensitively reflecting
The use of TIGRE enables dynamic imaging in organs such as the
differences in magnetic susceptibility
liver. The large fat component in the abdomen and breast regions
High-speed, high-resolution 3D T2*WI imaging is used to acquire require high-precision fat suppression. We have realized uniform fat
images that sensitively reflect differences in magnetic susceptibility. suppression effects and dynamic imaging in the abdomen and breast
Our BSI offers high-speed imaging due to EPI measurement. through combined use of high uniformity of the static magnetic field Breast TIGRE image

Venous blood and hemorrhage cause loss of signals in T2* images and H-Sinc which corrects for RF non-uniformity.
due to BOLD (blood-oxygen level dependent) effects. BSI performs Slice encoding

minimum intensity projection (minIP) processing and superimposes H-sinc


Phase encoding

phase information to further increase the contrast of images. Number of


Dummy segments

Examples of BSI (minP) images


TIGRE principle diagram

FatSep Abdominal dynamic image (TIGRE)


Fat suppression method resistant to changes in Fat Water
T2* RelaxMap/R2*RelaxMap †
magnetic susceptibility using frequency differences
Color map display of T2* values to improve
between water and fat
Out of phase Water image the visibility of iron deposition RF

Echo
Using the difference in resonant frequencies between water and fat protons
This function can map the distribution of T2* values to improve the visibility of
due to chemical shifts, both water and fat images can be acquired in one Principle of fat/
water separation Anatomical image T2* RelaxMap
iron deposition in liver tissue. A special sequence based on the GRE method
round of imaging. FatSep acquires data when the MR signals of water and In phase measurement Fat image
Signal
strength
(ADAGE) is available to acquire MultiEcho images used to automatically calculate
fat are respectively in-phase and out-of-phase, and adds or subtracts them
Anatomical +
T2* values. When analysis is conducted on the console, a color map of these T2*
to generate water and fat images. T2* value image

values is superimposed on a morphological image to create a T2* RelaxMap. T2* coefficient


FatSep can output images according to a degree of change in magnetic
You can also create an R2 (Relaxation rate) map based on 1/T2* values. The MultiEcho sequence and Echo count
susceptibility. If there is a greater change in magnetic susceptibility, Fine T2* attenuation

relative color display of an area with shortened T2* values can be used as
mode can be selected to give a high-definition phase map and enhance
FatSat FatSep Normal FatSep Fine a quantitative evaluation of iron deposits.
the image quality.

† Optional
13 14
Smart IMA GE GA LLERY
Nu e ro Va s c u lar-I mage S pi ne -i m a ge

DWI BSI

ADAGE-T2*WI

FatSep-T2WI (In) FatSep-T2WI (Sub)

3D-TOF MRA (MIP) ASL-Perfusion BPAS

HighRes-T2WI

3D-TOF WideMRA (MIP)

isoFSE-FLAIR (VR) isoFSE-MPR (SAG) isoFSE-MPR (COR) WholeSpine-T2WI 3D-BASG (MIP) 3D-RSSG-MPR (Obl) HighRes-T2WI (Reverse)

Bo d y - i m a g e M S K-i m a ge

RADAR-FatSat T2WI (RG)

3D-isoFSE MRCP (MIP)


HighRes-PDWI ADAGE-T2*WI
Body-DWI (Reverse)

VASC-ASL (MIP)

ADAGE-T2*WI

VASC-ASL (VR) VASC-ASL (MIP) BASG-Cine VASC-FSE (MIP) WholeBody-DWI (MIP) FatSat PDWI HighRes-T2WI T2 RelaxMap (ColorMap)

15 16
Hard/ECHELON Smart

S m a rt To b o o s t y o u r

O PE R ATION p r o d u c t i v i t y, E C H E L O N
Smart offers features
A comprehensive range of features that streamline operation
t h a t s t r e a m l i n e wo r k f l ow
for greater diagnostic performance
and enhance throughput,
s u ch a s A u t o Po s e a n d
Workflow Coil System AutoPose
Receiver coils support ease of patient setting and offer superb image quality Operation time reduced with assistance for selecting the imaging cross-section Pa r a m e t e r G u i d a n c e

The number of receiver coils that must be set prior to the examination is minimized to Slice line setting can be time-consuming even for experienced operators. AutoPose helps function for easy and
reduce replacement time and effort. With a system designed for ease of use and with you to determine the slice line more quickly and accurately. Following the acquisition
fast operation.
the adoption of special receiver coils for individual regions, significant reduction in of a scanogram, the AutoPose process takes one or two seconds to move the slice line
examination time is attained whilst maintaining high image quality. automatically to the preset cross-section. During the acquisition of a sensitivity map, fine
manual adjustment of the slice line can be performed, ready for imaging to start.
Workflow Coil System
Sensitivity map
for head & neck for spine for abdomen for joints Acquisition sequence
Traditional Scanogram T1WI T2WI
method
Manual positioning

Sensitivity map
Positioning
Acquisition sequence
time
AutoPose Scanogram T1WI T2WI
reduced
Fine
AutoPose
adjustment

Time

Workflow coil system Setting examples

[Slice line preset window] [AutoPose slice line]


This function is available immediately after installation The one or two second AutoPose processing sets the slice
using registered preset cross-section settings that suit the line according to the cross-section setting registered for
[Spine examination] [Head and neck examination] needs of your medical institution. your medical institution.
- Head and neck coil (posterior side) + [Spine examination]
WIT spine coil - Head and neck coil

User Interface
Streamlines setting and changing of protocols

An easy-to-use interface is available.

Suggestion UI
Supports change of imaging conditions
[Abdomen examination] [Extremity examination]
-Head and neck coil [posterior side] + -Head and neck coil [posterior side] +
This function provides guidance for parameter settings. During protocol change, several
WIT spine coil + Flex body upper coil WIT spine coil + GP flex coil
candidates are displayed to allow the operator to select the parameter most appropriate for
that particular scenario.

17 18
Hard/ECHELON Smart

S m a rt
H ARDWA RE
Our technologies enhance image quality

E C H E L O N S m a r t is SmartENGINE High Performance Gradient System


Optimizing the image SN ratio on multi-channel receiver coils High slew rate compatible with high-speed and high-performance imaging
e qui ppe d w i t h powerf ul
s u b-s y s te m s which The ECHELON Smart is powered by a high-speed A/D converter (Analog to Digital Shortening the TE (echo time) for signal receiver is essential for achieving high-speed imaging,
Converter) which directly digitizes the high frequency signal, suppressing noise to enhance excellent MRA images, and high-performance imaging. ECHELON Smart's powerful gradient
i ncl ude s t he S martENG INE image quality. It also incorporates an optimum image synthesizing technique allowing the magnetic field system with a high slew rate power supply of 130mT/m/s can shorten the gradient
precise adjustment of the image synthesis ratio taking into account the noise correlation magnetic field stabilization time and consequently can further shorten the minimum TE.
w hi ch suppo r t s high
during composition of signals from the elements to improve the total image SN ratio by Furthermore, this slew rate is sufficient to support super-high speed sequences such as EPI that
q u a l i ty i m a gi ng and high 8%† and thus provide excellent clinical images.This technology is particularly effective for generate echo signals continuously. By reversing the gradient magnetic field, it is effective for
multi-channel receiver coils in which the coil elements are segmented. imaging that requires high-speed switching without influencing the image quality.
p er f o r m a nc e R F s y s tem to † Varies by receiver coil and imaging conditions.
Stabilization time Example of super-high speed
e m powe r ro bus t im aging Gradient
sequence (EPI)
High slew rate
magnetic field
t echno l o gi e s. waveform ・・・

Echo time: TE
Stabilization time
Low slew rate
Gradient
・・・
magnetic field
waveform

Echo time: TE
16-channel receiver coil imaging setting

16ch Receiver System


Doubling the number of receiver coils to improve the reception High Performance RF System
sensitivity and stability during high-speed imaging RF power output that ensures stable maintenance of radiation waveforms

The elements of the receiver coils have been downsized to double the number of receiver channels ECHELON Smart is equipped with an RF power output of 18 kW. This is sufficient to provide
from 8 to 16. This has improved the receiver sensitivity, achieved a high image SN ratio, and clear images without deterioration of image quality even in the FSE sequence that applies
realized low-noise receiver from multi-channel receiver coils in the abdomen and other regions, refocus pulses continuously.
for which independent receiver was not possible using an 8-channel system. When the RAPID
high-speed imaging function is used, the greater the number of receiver coil elements, the more
redundantly the expansion information can be obtained. This ensures stable imaging. 180°

90°
ECHELON Smart
8-channel receiver system 16-channel receiver system
Sufficient RF power RF

BL1 BL2 BL3 BL4 BL1 BL2 BL3 BL4

BL5 BL6 BL7 BL8 ch1 BL5 BL6 BL7 BL8 ch1 ch9
ch2 ch2 ch10
ch3 ch3 ch11
Flex body upper coil ch4 ch4 ch12
SL4 SL3 SL2 SL1 SL4 SL3 SL2 SL1 180°
ch5 ch5 ch13
90°
SL8 SL7 SL6 SL5 ch6 SL8 SL7 SL6 SL5 ch6 ch14
ch7 ch7 ch15 Insufficient RF power
SL12 SL11 SL10 SL9 ch8 SL12 SL11 SL10 SL9 ch8 ch16 prolonging radiation RF
intervals
SL16 SL15 SL14 SL13 SL16 SL15 SL14 SL13

WIT spine coil A total of 24 elements are bundled into A total of 24 elements are bundled into
8 channels 16 channels

19 20
Sentinel Analytics
(†1)

Improving the uptime through failure sign diagnosis

Achieving higher uninterrupted system availability and optimizing maintenance costs remain challenges for

conventional remote support services for medical devices. We have accumulated and analyzed Big Data to

develop a new system that utilizes its "Failure Sign Diagnosis Service" to launch "Sentinel Analytics," a failure

sign diagnostic service for superconductive MRI systems.


With the failure sign diagnosis based on IoT (†2), the inspection and parts replacement cycles can be optimized and the system's up time can be improved.

Highly accurate failure sign diagnostics


Sentinel
Adoption of Lumada (†5)

Big Data Machine learning

Failure sign diagnostics Predictive


Sensor data Sampled data
maintenance
Sentinel Analytics
Collection

Data accumulation
Collect data from systems Pentaho (†4)
through IoT/M2M (†3)

Major features and advantages Conceptual diagram of Sentinel Analytics Service site

Constant system monitoring


The Sentinel server monitors the system status 24 hours a day.
Sentinel browser
Fire wall
Monitoring information check, System status screen
Automatic notification feature operation diagnosis, etc.
When the Sentinel server detects either a malfunction or a lowered performance of the system, Internet
an alert is automatically reported to our service site. This helps to prevent the occurrence of a Fire wall
Server site
malfunction. Furthermore, a corrective measure is quickly taken in case of malfunction.
Server group
Monitoring information
Direct connection feature Customer's site collection, information control,
communication control
This feature provides service via direct connection of the service site and your system.To track Fire wall
When error is detected
down the causes of a malfunction, we check artifacts and abnormal images, check image data Our service personnel
before reconstruction (raw data) and run test programs on the system.

Security
Such features as encryption of communication data and communication based on mutual Automatic notification mail
authentication are available to protect patient information. Furthermore, the specification does not †1 Service contract is required.
†2 IoT (Internet of Things) : A system in which various devices with communication functions exchange information via the Internet to realize identification, monitoring, and
allow recognition of personal information included in Patient Lists and images (such as an patient's
control of such devices.
name, sex, weight, age, and date of birth) on the Sentinel server and the Service Site. †3 M2M (Machine-to-Machine) : A system of direct exchange of information between machines via a network without human intervention.
†4 Pentaho : Big Data analysis software available from Hitachi Vantara LLC.
†5 Lumada : Lumada is Hitachi's IoT Core Platform.