SD Series 3 phase
GENERAL SPECIFICATIONS
8 www.epcas.com.tr
Rectifiers
SD Series 3 phase
Technical Specifications
MODEL 3 Phase ınput
INPUT
Nominal Voltage 3 x 190 / 200 / 360 / 380 / 415 Vac Phase to Phase
Nominal frequency 50 or 60 Hz
Transformer Galvanically isolated
ITHD <8*-30% standard (* 12 pulse)
Input Protection Thermic Magnetic Overcurrent protection MCB, Overvoltage protection
OUTPUT
Floating Output Voltage 12 VDC / 24 VDC / 48 VDC / 110 VDC / 220 VDC
12/24VDC output: 10VDC to 30VDC, 48VDC output: 40VDC to 60VDC,
Output Voltage Adjustment
110VDC output 80VDC to 150VDC, 220VDC output: 190VDC to 290VDC
Output Current Adjustment 10-100% of Nominal Output Current
Battery Charger Current Adjustment 10-100% of Nominal Output Current
Boost Charger Voltage 100% to 120% of Floating Output Voltage
Boost Voltage (V/C) 2,4 Lead Acid Battery 1,65 NiCd Battery (User can set other values base on battery'' datasheet)
Float Voltage (V/C) 2,25 Lead Acid Battery 1,42 NiCd Battery (User can set other values base on battery'' datasheet)
Nominal Output Current 30A / 60A /100A / 300A / 500A / 1000A ... 10.000A
Max Output Current 100% of nominal output current
Filtering LC Filter
GENERAL
Bost Timer 0-99.9 hours adjustable
Cooling Forced fans with smart fan controlling system
Isolation Voltage 1500 or 3000VAC input/chassis and output/chassis
Efficiency at full load >85%
Protection level IP20 (Standard); IP31/ IP41 / IP42 / IP54 (Optional)
Cable Entry Front Bottom
Access to Batteries Batteries and rectifier in the same cabinet with front access (optional)
Circuit Breakers Thermic-magnetic circuit breakers for input, Battery and Load (up to 100A)
Reset Button Used for re-operation in case of fallure of the system.
DISPLAY PANEL
Measurements LCD Display for Load Output Voltage / Current, Battery Output Voltage
Buttons Current and Line Voltage / Line Current / Frequency
Time and Date Timer Settings, Boost Voltage Setting, Float Voltage Setting, Output
Charger Failure Current Setting, Battery Current Setting and Reset buttons.
Low Battery Adjustable
Rectifier over voltage Open or closed free contacts
Over temperature Open or closed free contacts
Line Failure Open or closed free contacts
COMMUNICATION & PARALLELING
Communication Open or closed free contacts
Paralleling Open or closed free contacts
OPTIONS & ACCESSORIES
Standard RS232 communication on real time base for remote monitoring and control.
Communication
Optional RS485 / Modbus
Paralleling Parallel Redundant (No need for extra kit for paralleling)
NOTE: All specifications subject to change without notice. Consult EPC’s Technical Support Department for special applications.
All names used above are registered trademarks of their respective owners.
www.epcas.com.tr 9