Typical MD Typical TVD ORG mw Degrad MW Burst Collapse

TOC ~ 1000 ft

1400 1400 9.6 8.33 1276 442 30" Casing

admin: TOC ~ 2900 ft


Rating for 171.29#
6500 6500 8.9 8.33 2809 1162 24" casing
admin: TOC~ 5000
Rating for 171.29#

TOC~ 8100
9600 9600 9.2 8.33 6185 2590 18-5/8" Casing

TOC~ 9600 FT

13600 13100 16.5 7 8830 4570 13-5/8" Casing

15600 14600 20.3 7 12033 10010 10-3/4" Casing

- - - - 15886 16420 4.5" Tubing

14900 ft 4.5" TOL

16500 15100 17 7 16350 16850 7-5/8" Casing

19000 15700 12.5 7 18280 21600 4.5" Liner Shoe

Cement

Original MW / Degraded MW

Gas Column

Packer Fluid
A Annulus
B Annulus
C Annulus
30" Casing
D Annulus

E Annulus
24" Casing
F Annulus

18-5/8" Casing

Original packer fluid 11.6 ppg


WELLHEAD ANNULUS SECTION - PRODUCTION NOMENCLATURE

MAASP FOR SECTION F ANNULUS - assuming bad cement.


MAASP FOR SECTION E ANNULUS - assuming bad cement
MAASP FOR SECTION D ANNULUS - assuming bad cement.
MAASP FOR SECTION C ANNULUS - assuming bad cement.
MAASP FOR SECTION B ANNULUS - assuming bad cement.
MAASP FOR SECTION A ANNULUS
ANNULUS B/W CASINGS MAASP TO BE LIMITED TO

PSI
30" X 24" ANNULUS. 300.00
18-5/8" X 24" ANNULUS. 733.46
13-5/8" X 18-5/8" ANNULUS 1544.26327272727
10-3/4" X 13-5/8" ANNULUS 62.4327272727278
7-5/8" X 10-3/4" ANNULUS 3692.89090909091
TUBING x 7-5/8" ANNULUS 5000