Wind energy

i Site
1 Ras ghareb
2 West of Nile
3 Kossir
4 Korymat
5 Nuberia
Station RAS West of KORYMAT ELKOSIR ELNOBARYA
GHAREB NILE(MINIA)
Wind energy
Input data
estimation by
SAM Software Wind
turbine
GEMSA. G.
97, 2 MW
GEMSA. G 114, GEMSA. G
2 MW 114, 2 MW
GEMSA. G
114, 2 MW
GEMSA. G 114.
2 MW

▪ Input data Hub 70 m 90 m 90 m 90 m 90 m


height
Wind resource file Turbine 20 20 20 20 20
➢ Download a wind per row
resource file from
the NREL WIND Number 5 5 5 5 5
Toolkit. of rows
➢ Use a wind Row 53 DEG 10 DEG -9 DEG -1 DEG -18 DEG
resource file stored orientatio
on your computer
n
from NREA
Row 12D 12D 12D 12D 12D
spacing
Wind energy
estimation by
SAM software

▪ Input data
➢ Wind Farm
Losses (10% of
the wind farm’s RAS
GHAREB MINIA KORYMAT KOSSEIR NUBERIA
total output)
➢ Park (WASP) Annual
model used as Energy
(kWh) 1.235E+09 931,636,000 655,657,000 7.34E+08 628,561,000
wake model
Capacity
factor (%) 70.4753 53.1756 37.4233 41.8956 35.8767
Wind energy estimation by windPRO SOFTWARE
Inputs Symbol definition
Location Done by using online map (BMI files) that holds information on geo-
referencing and coordinate system.
Elevation map allows for importing irregular grid data (elevation) and comprehensive
graphical representation of elevation data.
Roughness map -For digitizing areas (polygons), e.g. forests, water and cities
-makes it possible to digitize/edit contour lines on-screen for use as digital
height contour lines, roughness lines etc.

Weather data Online data gives access to data on the EMD On-line server.

Site Data input of local terrain (roughness etc.) and regional wind statistic.
Meteo Object to import measured wind data for generating wind statistics or directly for
energy calculation.
Turbine selection creates a single WTG or row with equal spacing.
Configuring solver . A major reason for calculating in the time domain is that it is now possible
to access good quality long term mesoscale wind data all over the world.
also local measurements can be used.
Wind energy estimation by windPRO SOFTWARE
Site Result Result-10.0% Capacity
PARK [MWh/y] Factor
[MWh/y] [%]

Ras Ghareb
1,410,267.4 1,269,240.6 72.4

Minea
1,033,689.2 930,329.6 53.1
Comparison of results between WindPRO and SAM
Ras Ghareb Annual Energy [Gwh/y] Capacity Factor

WindPRO software 1269.2406 72.4%


SAM software 1234.7274 70.5%

Minea Annual Energy [Gwh/y] Capacity Factor

WindPRO software 930.3129 53.1%

SAM software 931.6359 53.2%